250 likes | 409 Views
Introducing GAC’s New Line of Intelligent Generator Set Controllers. The InteliGen. Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications Features: 128 x 64 LCD 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable
E N D
Introducing GAC’s New Line of Intelligent Generator Set Controllers
The InteliGen • Stand-By, Prime Mover (single and multiple set), and Parralel to • Utility (single and multiple set) Applications • Features: • 128 x 64 LCD • 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable • to 21 / 21 • 3 Analog Inputs (Fuel Level, Coolant Temp., Oil Press.) • Expandable to 7 and 1 Analog Output • Speed Measurement (Mag Pick-Up) • 3 Phase Generator / Utility Voltage Measurement • 3 Phase Generator Current Measurement • 1 CT Input for Utility Measurement or Earth Fault Protection • RS232 for Direct Communication • Meets NFPA110 (w/ Annunciator Module iGL-RA15) • Remote Communication (Analog, Internet, and GSM)
InteliGen Connections 3 Phase Utility Voltage 3 Phase Generator Voltage 9 Configurable Discrete Inputs and Current Connection for IOM / COM Module Connection for Power Modules Mag. Pick-up 3 Analog Inputs (Oil, Temp., Fuel.) Direct PC or Modem Connection Utility Current 2 Relay Outputs (Starter, Fuel Solenoid) 7 Config. Outputs 12 or 24 V DC
InteliGen’s Modules • Power Control Modules: PCM and PCLSM (with Load • Sharing) • AVR control (needs 18 V AC power supply) • Communications • Expandable I / O • Modem Support (multiple set applications)
Power Control Modules Shielded Analog Load Sharing Line(PCLSM only) Governor Control Output AVRi Output Mounts Directly to Back of InteliGen 12 or 24 V DC 4 Discrete Inputs 4 Discrete Outputs
AVRi Module Output Level Adjustment (turn pot) 18 V AC Power Supply Output for AVR Control Input from PCLSM DIN Rail Mounting
Communication Module • Used for Multiple Set Applications • Communications Between Sets • Mount: Back of InteliGen • Up to 32 Sets • Use one Modem (w/iG-MU) • RS232 port for IOM
IOM / PTM Module 9 Discrete Inputs w/ Active LED 4 Analog Inputs* 1 Analog Output RS232 for Direct PC Connection RS232 Connection to InteliGen 9 Discrete Outputs w/ Active LED 12 or 24 V DC w/ Power LED DIN Rail Mounting
InteliMains: InteliGen With Special Software • Mains (= Utility) Circuit Breaker Control • Reverse Synchronization • Vector surge protection (locally required) • Power Management - Engine Usage Optimization • Number of running engines: Dependent on required load • Engine starting order: Dependent on running hours • Import/Export Control
iG-COM iG-COM G G iG-PCLSM iG-PCLSM Parallel To Utility & Other Gen Set’s + iG-COM + iG-PCLSM InteliMains + iG-COM + iG-PCLSM
InteliGen’s User Friendly Operating Software Setpoints Controller • Free • User Friendly • PC Format History Values
Value Screen All Metered Values in Real Time. Metering Screen Selection
History • Every Action Logged • All Values Associated • w/ that Action • Up to 177 events • (FIFO)
Controller • Same as Keypad • Essential Metering • Alarm List
Setpoints • Change any Setpoint • Current Value • Range Value Screen Selection Acceptable Range for Parameter
Customizable Software • Parameters • Nominal RPM 80 300 • Multilingual Texts • Overspeed Überdrehzahl Sobrevelocidad • Units • °C F; kPa bar psi • Controller Operating Mode • SPM SSB SPtM MINT MEXT • Text • Water temp Coolant temp
Water Temp 91°C Oil Pressure 5.1bar Fuel level 75% Battery voltage 25.2V Controller Screens • Analog Meters • Bar Graphs • Numeric Values • Controller Screens Allow for Similar • Interface as WinEdit Software MAINS: 230 228 233V 50.0Hz GENERATOR: 1517RPM 221 223 220V 50.6Hz 872 896 932A 0.98L 183 194 208kW 118kVAr Running in Island
Setpoint Adjustment • Adjustable via iG Keypad • Three Level Password Protection PARAMETERS MF-Start Delay 3s Start Attempts 5 Mains OK-Delay 10s Cooling time 30s
History Screens • History Events Can be Viewed From iG Screens • as well as WinEdit • Viewed on Multiple Screens -15 FINISHED HOUR 07:00:00 16.10. -16 GCB CLOSED-ISLAND 06:23:53 16.10. -17 ENGINE START 06:23:49 16.10. -18 MF-MCB OPENED 06:23:44 16.10. 85kW 1503RPM 0.81L 88C 6.1bar 24.9V 84% 50kW 1495RPM 0.72L 25C 5.3bar 24.7V 87% 0kW 0RPM - 22C 0.0bar 25.8V 87% 0kW ORPM - 22C 0.0bar 25.8V 87% M 0 0 0V 0.0Hz G233 227 229V 50.1Hz M 0 0 0V 0.0Hz G230 228 223V 49.8Hz M 0 0 0V 0.0Hz G 0 0 0V 0.0Hz M190 195 201V 48.7Hz G 0 0 0V 0.0Hz 121 125 124A 62kVAr 27 29 29kW 72 73 71A 48kVAr 17 18 16kW 0 0 0A 0 0 0kW 0 0 0A 0 0 0kW
Protection Handling • Adjustable Delay Settings • Five Protective Actions • Warning • Slow stop • Shut-down • Unloading • History Record • Reset Function (Horn + Flashing Light)
Protections • Generator / Utility Over / Under Voltage and Frequency • Voltage and Current Asymmetry • OverCurrent • OverLoad • Excitation Failure • Earth Fault • Oil Pressure (two level: warning, shutdown) • Coolant Temp. (three level: low temp warning, • high temp warning, and high temp shutdown) • Fuel Level (two level: warning, shutdown) • …
Summary The InteliGen Offers the Right Solution for the Application. Never Pay for Unneeded Features. GAC Leaves it up to You to Make the Intelligent Choice!!