A Low Dispersion Prism for IMACS f/2 (LDP)

A Low Dispersion Prism for IMACS f/2 (LDP). A lower dispersion element affords more slits per mask at the expense of resolution (less pixels in a given wavelength range). For faint galaxy surveys, the primary observable per galaxy is redshift.

finnea
Download Presentation

A Low Dispersion Prism for IMACS f/2 (LDP)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A Low Dispersion Prism for IMACS f/2(LDP) • A lower dispersion element affords more slits per mask at the expense of resolution (less pixels in a given wavelength range). • For faint galaxy surveys, the primary observable per galaxy is redshift. • What’s the fewest number of pixels required to obtain a redshift to a specified precision? Crudely: Npix * s(z) ~ 1. • Because of the f/2 wide F.O.V., grisms operating at 100 l/mm and below will be strongly affected by zero-order light (direct images of slits). • A prism (or series of prisms) will disperse a very broad wavelength range (4000Ang-1 micron) over a small number of pixels. • No blaze condition, no preferred wavelengths. • But… a very non-linear dispersion pattern LDP Prism description

  2. Current Prism Schematic (7/24/05) 83.66mm LDP Prism description

  3. Ray tracing for IMACS f/2 rays from 400nm to 1000nm. 400nm 500nm 600nm 1um LDP Prism description

  4. Resolution of LDP prism with IMACS f/2 3pix 4pix LDP Prism description

  5. Advantages of Prism High throughput, no blaze condition Up to a factor of 2 more efficient Full wavelength coverage High slit density, up to 5000 per f/2 mask Advantages of Grism Linear wavelength dispersion Choice of wavelength range and blaze wavelength. Can resolve strong OH lines. Why prism and not grism? LDP Prism description

  6. Efficiency Curve for 300 l/mm transmission grating from Richardson Grating Lab website Expected Prism Efficiency Efficiency(%) LDP Prism description

  7. PRIMUS survey with LDP+IMACS f/2Burles, Eisenstein, Coil, Blanton, & Hogg • Goal to observe 1 square degree down to I < 23.5 in 2006A to test target selection, optimal observing strategies and redshift success in well-tilled survey fields (i.e. CDF-S & COSMOS) • Compare redshift precision with classic grating/grism surveys, as well as photometric-z surveys like COMBO-17 • Will require some custom slitmask design and observing strategies, as well as some challenging data reduction and redshift identification algorithms. • Our goal is to obtain 50,000 redshifts in Spring 2006, with time allocation through MIT & Arizona. • If successful, we plan to embark on a larger multiple square degree survey to get underway in Fall 2006. • This observing mode may be well suited to follow-up planned SZ fields. LDP Prism description

  8. LDP Prism description