Some RF contacts and power transmission lines

Some RF contacts and power transmission lines. Annual maintenance of RF power transmission lines in BA3 Philips plant. Once per year, we have to dismount 16 RF power amplifiers to make their maintenance To do so, we need to disconnect their output power transmission lines

flann
Download Presentation

Some RF contacts and power transmission lines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Some RF contactsandpower transmission lines

  2. Annual maintenance of RF power transmission lines in BA3 Philips plant Once per year, we have to dismount 16 RF power amplifiers to make their maintenance To do so, we need to disconnect their output power transmission lines With this 35 years old equipment, we recently experienced some difficulties with the innerspring contact clamps

  3. Innerspring contact clamp Innerspring contact clamp ensures continuity of the inner line of the 35 kW CW RF transmission line

  4. Possible mistakes Too long spring Impossible to mount inside the inner line As it was too difficult to insert it in the inner line, mechanist decided to shorten the RF spring contact See next slide for consequences…

  5. Bad RF contact consequences Original clamp size After operation at 35 kW @ 200 MHz with bad contacts Even worse

  6. Correct procedure Compress the spring to the selected length Roll it up ensuring a good spirals distribution including the connecting point A very simple process to ensure a correct contact Once compressed cut it guarantying the correct number of spirals

  7. Additional examples… Wrong lamella angle : burnt contacts Another clamp burnt because one of the finger contact was mistakenly inserted in the inner side instead of the outer side