1 / 20

به نام خالق هستي

به نام خالق هستي. دكتر كتايون خداورديان آزمايشگاه مرجع سلامت. دستورالعمل نمونه گيري وريدي ومويرگي. VENIPUNCTURE.  Pre collection: smoking, physical activity, stress During collection: -different time of day -posture: lying/standing/sitting

Download Presentation

به نام خالق هستي

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. به نام خالق هستي دكتر كتايون خداورديان آزمايشگاه مرجع سلامت

  2. دستورالعمل نمونه گيري وريدي ومويرگي

  3. VENIPUNCTURE Pre collection: smoking, physical activity, stress During collection: -different time of day -posture: lying/standing/sitting -haemoconcentraction: prolong tourniquet Handling of specimen : - Insufficient or excess anticoagulant -Inadequate mixing of blood with anticoagulant -pat./or specimen identification error -delay to transit to Lab.

  4. Room Facilities • Venipunture chair& Bed • Blood collecting Trays • Gloves • Needles&Holders • Sterile Syrings • Venous Blood collection Tubes • Tourniquets • Antiseptices • Guase Pads→5*5cm,7.5*7.5cm

  5. Punture –Resistance Disposal Container • Ice or refrigerator • Adhesive Bandages • Warming Devices • Test Reference Manual

  6. Venipuncture Procedure 1- Identify the patient 2-Assess the patient physical disposition (diet, exercise ,stress,basal state) 3-Equipment→ necessary supplies&Tubes 4-Position the patient 5-put on gloves 6-Apply Tourniquent →7.5-10cm above ven. Site , Not too tightly No more than 1 min. Patient should make a fist without pumping the hand 7-Select the vein site Median cubital & CephalicVein *Extencive scaring from burns & surgery Mastectomy * Hematoma * IV therapy →below IV site *Cannula,Fistula* Edematous

  7. VENIPUNCTURE SITES

  8. 8- Clean the site →Isopropyl or Ethyl Alcohol 70% ►guaze pad → 5*5-7*7cm -Circular motion from center to the periphery *allow to air dry 9-Insert needle ≤ 30degree 10- Drawing the spec. * open the hand 11- Release Tour niquet 12- Place gauze pad over the vein 13- Re move the Needle 14- Applying pressure to the site, making sure bleeding has stopped 15- Collect the sample in the appropriate tubes (Blood culture - coagulation Tube- non additive Tube- Heparin - EDTA Tubes)

  9. 15- Disposing needles 16-Lable the tubes and record the time of collection: name ,age,IDno.,Dr. name,other Inf.(Iv site …) ٭ All Tubes must Labeled Immediately after blood specimen has been drawn. 17-Chill the specimen (if required) 18-Send to Labs. ٭Children→ syringe gauge 20-23, winged blood collection set

  10. Safety& Infection Control • Wear gloves &lab coats when handling bloob/body fluids • Change gloves frequently or if contaminated • Wash hands frequently • Dispose of needles immediately Do not bend, recap,break,resheath needles • Clean up any blood spills with a disinfectant as freshly made 10%bleach

  11. # Prolonged Tourniquet: Hb, HCT, RBC ↑ 2-3% # Prior rest: - Hb, HCT, RBC ↓ 5-8% (1.5 hr bed rest) - Lymphocytes ↓ # Position of Arm : H b, H C T, R B C ↑ 2-3% in hanging down arm # Diurnal Variation : Hb, HCT higher in the morning than evening WBC & Neutrophil counts higher in the afternoon Lymphocyte lowest in the morning and highest in the evening . PLT is higher in the afternoon and evening Cortisol, Fe # Excersise : - WBC, RBC, Hb, HCT rise - intensive tranning ↓ lymphocyte count -↑ CK, AST, LD, Fibrinolysis,&Activate coag. - physical training: ↑sexial hormons

  12. Skin Puncture 1- Equipment 2- Choose the puncture site ¤ distal digit of third or fourth finger ¤ lateral or medial planter surface of heel(pre warming 420 3-5 min) 3- Puncture with sterile Lancet (No deeper than 2mm) 4- Wipe the first drop 5- Collecting the specimen

  13. Punture must be on palmar surface of distal phalanx across the fingerprints,of the middle&Ring finger.

  14. Blood must not be obtain from the: -Ear lobe -Central area of an infant heel -Swollen or previously punctured site

  15. Difference between capillary and Venous Blood - RBC, Hb, HCT capillary blood are slightly greater than venous – leucocyte and PMN are higher 8% Monocyte 12% -PLT count higher in Venous blood 9% -Glucose is higher in capillary blood, K, Protein,Ca is lower ✽ Smears prepared from capillary blood shows PLT aggregation

  16. STORAGE • CBC→up to 4 h.(max. 6 h.) at room Tem. • Cell counts & Indices are stable for 24 h. at 4c • Blood smear→1 h. at room Tem. by 3 h. blood cell morphpology starts: - vacuolisation & irregular lobulation of nucleos -crenation &sphering of RBC(after 6 hours) • Quantitative effect (>4-6 h.at room tem): -RBC swelling→MCV, ↑HCT, ↓ESR - Leucocytes & plt→gradually fall (count with 2 h.) - Hb remains un changes for days • ESR:up to 4 hours at room tem. up to 12 hours at 4 degree

  17. Reticolocyte:EDTA sample up to 6 hour at room tem. up to 24 hours at 4 degree • Blood grouping sample:48 hour at room tem. up to 7 days at 4 degree

  18. Rejection of Samples • Hemolysis - this is usually caused by a procedural error such as using too small of a needle, or pulling back to hard on the plunger of a syringe used for collecting the sample. The red cells rupture resulting in hemoglobin being released into the serum/plasma, making the sample unsuitable for many laboratory tests. The serum/plasma will appear red instead of straw colored. • Clotted - failure to mix or inadequate mixing of samples collected into an additive tube. The red cells clump together making the sample unsuitable for testing. • Insufficient sample (QNS) - certain additive tubes must be filled completely. Incorrect blood to additive ratio will adversely affect the laboratory test results. When many tests are ordered on the same tube be sure to know the amount of sample needed for each test. • Wrong tube collected for test ordered. Always refer to procedure manual when uncertain. • Improper storage - certain tests must be collected and placed in ice, protected from light, or be kept warm after collection. • Improperly labeled

  19. Thanks for your attention