1k likes | 1.14k Views
Make your premises an Oasis of security. Oasis_EN_ 1010 _c1. A solution for your security & comfort. Oasis is a wireless kit. Sirens. RFID cards. Keypads. Control Panel. Wireless detectors. Motion detection. Fire & Gas. Glass-break detectors. Temperature. Window, door opening.
E N D
Make your premises an Oasis of security Oasis_EN_1010_c1
Oasis is a wireless kit Sirens RFID cards Keypads Control Panel
Wireless detectors Motion detection Fire&Gas Glass-break detectors Temperature Window, door opening..
Wireless buttons Wall-mount button Door bell Panic Wireless relay Key-fob
Basic features • 50 addresses for wireless devices (detectors, RC, keypads and sirens) • 50 positions for user codes or/and proxy cards • 4 wired inputs in the control panel ( plus inputs in keypad and detectors) • (additional 10 inputs via JA-82C module) • Lithium batteries – calculated lifetime 3 years • 868 MHz operating frequency • Grade 2 by the EN 50131 standard (medium risk)
JK- 82 Kit Set-up your system from individual items or just use the starter kit..
JK-82 consists of: • Control panel with GSM communicator • Wireless keypad • PIR detector • Magnetic detector • Indoor siren • Key fob • Wireless door bell button • Proximity card • Accessories (batteries etc.)
Kit installation 6 5 1 4 3 7 2
Service mode after powering up • A:Enrollment ofmore devices • key 1and connect batteries, exitwith # • B: Communication quality test • key298 (turns on signal measurement) • arrow keys scroll devices • device triggering = signal from 1/4 to 4/4 • # returns you to Service mode • C:GSM signal strength test • key922 • return to Service mode by # • Each signal should be at least 2/4
Service mode after powering up • A: Enrollment of more devices • By keying in production code (on keypad or computer) • By enrollment • Press 1 to open enrollment (*08080 for the service mode) • Scroll to desired position • Insert battery to enroll the item • Erase the position by holding key 2 in enrollment • Enrollment can also be opened by shorting the reset pins
Optional antennas • AN-80 • AN-81 • Can be used with control panel and UC-82 receiver
JA-80Z Repeater • Repeats RF signals of up to 40 enrolled items • Working range can be enhanced up to 2x • Shows signal strength of enrolled items • Hardware of JA-82K + JA-82R • Two-way communication with the control panel- copy PGX, PGY, EW, IWoutputs • Hardwired inputs TMP, INP • JA-80F, JA-84P, JA-80A cannot be enrolled
Wireless communication Robust protocol = reliability • Integrity check –Supervision • Code grabbing protection- Floating code • Code searching protection - Antiscan • Anti-jamming protection • Anti-collision protection • Diagnostics = to see communication quality
Programming • After power-up first set language of the keypad and communicator • Set other parameters - example: 98101 EN communicator language 4 hh mm DD MM RR = clock 201 Exit delay 10sec. 811„phone num“*0= phone number The best way is to use Olink SW
299 enrollment of PGX to AC relay X • 237 PGX function = on / off
Handover to the user • Explain the basics (less = more) • Always recheck that user understands ? ?
Operating a key-fob SET (arm) UNSET (disarm) Both buttons = PANIC
Keypad layout Alarm or faultSET A, B and C Power Details Setting (arming) Hot keys A, B & C PGX On / Off Detail reading
Let the user feel that (s)he is the master • „Master“ card enrollment: * 5 1234card • Access card enrollment: * 6, Master card, keynn, card • Access code programming: * 6, Master card, keynn, code • To erase access code and card: * 6, Master card, keynn, 0000 nn= user number 01 to 50 Each user can have code, card or both John 2375
2 level partial arming Example:Family house Garage,... Set (armed) by: KeyA Garage + Groundfloor A Key B A B Complete arming C C Key ABC A B A B
Split system Example: Two families in a house, two offices.. Brown ARMED Set (armed) by: A B Code or card Brown C Ward ARMED Code or card Ward A B C Entire house armed incl. Common section If both A+B armed, then C also armed A B C
Communicator test Both buttons „Panic“ Panic alarm SMS • Function test • Knowing the SIM card tel.number
Remote access SMS instructions:„CODE space INSTRUCTION“ Phone call: • Call and wait for the system to respond (after 5 rings) • Enter a valid code (master, user or service) • Operate the system… hang up at the end
The JA-82K control panel • Modularity • JA-82K control panel = 4 inputs • JA-82R = radio • JA-82C = 10 inputs • 50 addresses for devices • Wired inputs • Wireless devices • Enrollment via radio comm. or • by keying in production codes • 50 addresses for codes / cards • Optional code+card configuration • Mains power supply and battery • Output 12V, 500mA • Memoryfor the last 255 events • Replaceable memory chip • Alarm outputs: EW and IW • Programmable outputs: PgX and PgY
The JA-83K control panel JA-82R radio module Power transformer1.1 A antenna Up to 30 wired inputs • Communicator: • 80X telephone line • 80Y GSM • 80V LAN + tel. line Back up battery up to 18 Ah
Hard-wired inputs • Hard-wired inputs addresses 01 to 14 / 30 (can be switched off by DIP switch or by SW) • Maximum of 5 detectors in a loop • Double balanced - triggering and tampering • Programmable reaction (Natural = delayed) • Enrollment of a wireless device to address 01 - 14 disables the input terminal • Connected to COM via a 1 k resistor = untriggered input • Connected to COM via 2 to 5 k = triggered input, • Connected to COM via less then 700 or more then 7k8 k = tamper signal
Control panelreactions • Devices and codes/cards can have reactions: • Off • NATURAL(key-fob, code and card = set / unset, smoke detector = fire alarm) • 24 hours • Instant • Delay (Natural) • Next delay • Fire • Panic • Set • Set / Unset • PG control • Every device, input, code and card can be assigned to section A, B or C Pepa 6319 Láďa 1507 Máňa 389 John 6319 David 1507 Peter 389
OLink SW Example of system management
The JA-81F keypad • Fully graphical display • Customizable logo (128x48) • Two versions • White backlight only • Settable backlight color JA-81F-RGB • Wakening by • External input • Gently pressing the keypad’s door • Internal menu • Language setting • Brightness • Contrast • Backlight color (JA-81F-RGB only) • Text editing • Manually or via Olink software • JA-82T direct connection support • JA-81E = hard-wired version
The PC-01 proximity cards • RFID access card (EM UNIQUE 125kHz) • Up to 50 cards can be enrolled to the system • The card has the same function as an access code • For higher security the card can be combined with a code • PC-02, PC-0x
The JA-80H outdoor keypad • Built in RFID reader • Connects to the control panel bus via WJ-80 • Provides a doorbell button • Illuminated keys • IP-65 • Standby consumption 45mA
The JA-80Noutdoor reader • RFID card reader • Connects to the control panel bus via WJ-80 • IP-65 • Standby consumption 40 mA
The WJ-80 interface • Connects outdoor keypad (reader) to the control panel • Built-in door bell transmitter (for JA-80L) • Output to operate an electrical door lock (Z8-12V) • Provides output to operate the electric strike of an electrical door lock an open button input • Keypad uses Wiegand protocol 26b • DIP switches: • System keypad / Outdoor bypass switch • PGY can operate the door lock as well (Y/N) • Door lock activation time 3 / 6 seconds • Exit & entrance beeps (Y/N) Sequence 248 = PGY pulse Authorized phone opening 777 775 022*9 To program 81 1 777 775 022 *79*0 Control panel bus
Wireless detectors • Powered by lithium batteries • Battery lifetime is up to 3 years (status is supervised) • Communication range about 200 – 300m open area • Communication supervision every 9 minutes • Detection of motion, glass-breaking, opening, smoke, heat, gas…
The JA-80P motion detector • PIR sensor • Hard-wired input IN(initiates same reaction as PIR) • 15 min test mode after closing the cover • 5min sleep time (can be shortened to 1 minute) • DIP switches • DEL / INS (Natural reaction) • NORM / HIGH (immunity level) • Covers 120° / 12m • Optional lenses (pet, long corridor, vertical curtain) • 1 x AA Lithium battery 3.6V
The JA-83P mini motion detector • PIR detector 1/3 smaller than JA-80P • 15 min test mode after closing the cover • 5 min sleep time (can be shortened to 1 minute) • DIP switches • DEL / INS (Natural reaction) • NORM / HIGH (immunity level) • Covers 120° / 12m • Optional lenses (pet, long corridor, vertical curtain) • 1x CR123A Lithium battery 3V
The JA-86P dual-zone detector • Dual PIR sensor resolves PET problems • Usable in extreme environment (cellar – mice, insects…) • Indoor use only • 15 min test mode after closing the cover • 5min sleep time (can be shortened to 1 minute) • DIP switches • DEL / INS (Natural reaction) • NORM / HIGH (immunity level) • 1 x AA Lithium battery 3.6V (3 year life time) • Principle: PIR1 + PIR2 = Alarm • JS-22 = wired version
The JA-84P detector with built-in camera 3 in 1: Flash Camera Motion detector
The JA-84P detector with built-in camera USB connector
The JA-84P detector with built-in camera Installation • The JA-80Q into the control panel • Photo transmission from the premises • Cooperates with an 80Y (GSM) or an 80V (LAN) communicator • Enroll the detector to the control panel • Enroll a key-fob to the detector • Close the detector’s cover (green LED) • Press any key on the key-fob • Camera testing • Set (Arm) button = with flash • Unset (Disarm) button = without flash • The key-fob is automatically erased after 15 minutes • Switch off radio interference indication • The photos can be displayed at: www.img.jablotron.com “Have your portrait taken.…”
The JA-84P parameters • Camera resolution: 160 x 120 B&W • Bi-directional communication • On activation takes 4 pictures: • 1x without flash • 3x with flash • Range of the flash: max. 3 meters • Detector’s memory capacity: 61 photos • USB port • Flash drive functionality • Photo transfer time to server: approx. 15s • Battery: 2x CR-123A • Lifetime approx 3 years (inc. 100 photo series) • Testing by key-fob • 4 configuration switches: • DEL / INS (Delayed / Instant reaction) • NORM / HIGH (PIR analysis) • ON / OFF Flash (flash) • ON / OFF Trans (photo transmission)
The JA-84P detector with built-in camera Detector coverage
The JA-84P detector with built-in camera • Register at www.img.jablotron.com
The JA-84P detector with built-in camera Displaying pictures on www.img.jablotron.com