An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SmartLoop otdrOTDR testing of two fibers in a single test

  2. Introducing smartloopotdr • Il primo OTDR con test automaticosufibradoppia! • Raddoppia la produttivitàrispetto ad ognialtro OTDR • Misura due fibre con un unico test. • Test Bidirezionalesenzabisogno di spostarsidall’altrolatodellafibra.

  3. RISPARMIA TEMPO MISURANDO 2 fibre in un Test

  4. COMPENSAZIONE LANCIO Lancio CompensazioneSmartLoop Loopback Coda CompensazioneTradizionale Lancio Coda

  5. Test 2 FIBRE Test SmartLoop Test direzione 1 Lancio Loopback Coda Test Tradizionale Test direzione 1 Lancio Coda

  6. Test 2 FIBRE Test SmartLoop Test direzione 1 Lancio Loopback Coda Test Tradizionale Test direzione 1 Lancio Coda

  7. Test 2 fibRE • Test SmartLoop • Test direzione 1 • Connessione a 2ndfibra • Test direzione 2 Launch Loopback Tail • Test Tradizionale • Test direzione 1 • Connessione a 2ndfibra • Test direzione 1 Launch Tail

  8. Test 2 fibRE Coda • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Loopback Lancio • Test Tradizionale • Test direzione 1 • Connessione a 2ndfibra • Test direzione 1 Lancio Coda

  9. Test 2 fibRE • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Lancio Loopback Coda • Test Tradizionale • Test direzione 1 • Connessione a 2ndfibra • Test direzione 1 • Connessionelatoremoto Coda Lancio

  10. Test 2 fibRE • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Lancio Loopback Coda • Test Tradizionale • Test direzione 1 • Connessione a 2ndfibra • Test direzione 1 • Connessionelatoremoto • Test direzione 2 Coda Lancio

  11. Test 2 fibRE • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Lancio Loopback Coda • Test Tradizionale • Test direzione 1 • Connessione a 2ndfibra • Test direzione 1 • Connessionelatoremoto • Test direzione 2 • Connessionea 2ndfibra Coda Lancio

  12. Test 2 fibRE • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Lancio Loopback Coda • Test Tradizionale • Test direzione 1 • Connessionea 2ndfibra • Test direzione 1 • Connessionelatoremoto • Test direzione 2 • Connessionea 2ndfibra • Test direzione 2 Tail Launch

  13. Test 2 fibRE • SmartLoop Testing • Test direction 1 • Connect to 2nd fiber • Test direction 2 • Done Lancio Loopback Coda • Traditional Testing • Test direction 1 • Connect to 2nd fiber • Test direction 1 • Connect to far end • Test direction 2 • Connect to 2nd fiber • Test direction 2 • Done Coda Lancio

  14. ProteGGI la PORTA otdr • Quandosieseguonoi test OTDR bi-direzionali, bisognalasciare le Bobine di Lancio e Coda collegate al link oggetto del test. • Ciòsignificacollegare e scollegarefrequentemente la fibraallaporta OTDR • Per proteggere la vostraporta OTDR siutilizzauna patch cord corta prima dellabobina di lancio/coda • Questa patch cord, 1 foot (33 cm), rimaneall’internodelladeadzoneevento dell’ OTDR, e quindi non influirànegativamentesulrisultatodellamisura • NON è la stessacosa se siutilizza la patch cord tra la bobina di lancio e il link sotto test Launch Short patch cable Loopback Tail

  15. PERCHE’ SERVE ILSmartloop otdr?

  16. Data centers e RETI AZIENDALI

  17. Data centers and enterprises • Problema • Centinaia di fibre da misurare. • Tempi Ristretti • Soluzione

  18. ToRRI E SITI REMOTI/ISOLATI

  19. ToRRI E SITI REMOTI/ISOLATI • Problema: • Difficoltà di accessoalleFibre. • Bisognasalire e scendere ad ogni test. • Pericoloso per personale e strumento in caso di caduta • Soluzione: • Utilizzo di loopback fiber • Il Tester rimane a terra • Misura di 2 Fibre in un unico test

  20. Outside Plant Construction and Maintenance

  21. Outside Plant Construction and Maintenance • Problema: • Lunghedistanzetrai due estremidellafibra. • InstallazioniAeree. • Pericoloso per personale e strumento in caso di caduta • Soluzione: • Utilizzo di loopback fiber • Il Tester rimane a terra • Misura di 2 Fibre in un unico test

  22. SmartLoop OTDR • GRATIS per tuttiiclientiVersiv • Inclusonella v3.0 • Non è un’opzione da installare • SmartLoop OTDR è unanuovaopzionedisponibilenel menu del setup dell’ OptiFiber Pro GRATIS Upgrade

  23. MODELLI

  24. Smartloop launch cables

  25. protect Your OTDR port

  26. GRAZIE Per ulteriori Info: VisitateOptiFiber Pro website www.flukenetworks.com/OptiFiberPro