An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Liquid XenonGamma Screening Luiz de Viveiros Brown University

  2. Simulation Settings • A simulation is set up to analyze the level of radiation in a Liquid Xenon detector caused by contaminants in Photomultiplier Tubes. The objective is to determine the efficiency of Xenon in screening gammas from the PMTs and to determine whether there are sufficiently large regions in the detector with background radiation below acceptable levels. • The target background is 6 x 10-3 counts/keV/kg/day. • Multiple scatter events can be filtered out by identifying the events with a large deposition spread, measured by calculating the energy weighted standard deviation of interactions in an event, and it is given by: • The depth of a event is defined as the energy scaled average position of all the interactions in that event, given by: • The target is a cylinder of Liquid Xenon, 30cm high and 30cm in diameter (65 kg). The PMT is represented by an isotropic point source of gamma-rays. The source is located 5cm above the liquid surface. All simulations are run with 1 million emitted photons.

  3. The simulation is run with a source that simulates the emission lines of the physical PMTs. For this simulated PMT, we used the Hammamatsu R8778 tube.  The radiation is due to 3 contaminants: Potassium (13 mBq), Uranium (5 mBq) and Thorium (13 mBq). 2D Hitogram – Energy vs. Depth Potassium / Uranium / Thorium Source – 31 mBq Total Activity On the rate scale, 0.00128 is the smallest detected rate and 0.006 is the target background rate

  4. Simulated PMT Source Potassium / Uranium / Thorium – 31 mBq Total Activity Energy Histogram Depth Histogram

  5. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each 2D Histogram – Energy vs. Depth On the rate scale, 0.00048 is the smallest detected rate and 0.006 is the target background rate

  6. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Energy Histogram

  7. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Depth Histogram

  8. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Depth: 10 cm – 20 cm Depth: 20 cm – 30 cm Radial Histograms

  9. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Copper Cryostat 1cm thick 2D Histogram – Energy vs. Depth On the rate scale, 0.00048 is the smallest detected rate and 0.006 is the target background rate

  10. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Effects of Copper Cryostat With Cryostat Without Cryostat Radial Histograms Depth: 10 cm – 20 cm Middle of Detector

  11. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Effects of Copper Cryostat With Cryostat Without Cryostat Radial Histograms Depth: 20 cm – 30 cm Bottom of Detector

  12. Background Analysis – 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Effects of Copper Cryostat With Cryostat Without Cryostat Depth Histograms

  13. Background Analysis – 2.5MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each 2D Histogram – Energy vs. Depth On the rate scale, 0.00019 is the smallest detected rate and 0.006 is the target background rate

  14. Background Analysis Background Rates for Sources of Different Energies Each source emitted 1 Million Photons, And has rated activity of 20 Low-Activity PMTs, 6 mBq each Number of Detected Photons for Sources of Different Energies Each source emitted 1 Million Photons

  15. Background Analysis 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Detectors of Different Depths 20cm, 30cm and 40cm 2D Histogram – Energy vs. Depth

  16. Background Analysis 1MeV Gamma Source 20 Low-Activity PMTs, 6 mBq each Detectors of Different Depths 20cm, 30cm and 40cm Depth Histograms

  17. Conclusions • The top 10 cm of the detector present high background rates and can be eliminated to bring the overall background below the target rate. • The outer layers of the detector have higher background due to the backscattering of particles off the cryostat. Two courses of action can reduce this background – increasing the radius of the detector and/or filtering out the events in the region closer to the cryostat. • The thickness of the detector does not significantly affect the background rate at all depths in the detector. The advantage of adding more Liquid Xenon to the bottom of the detector is the increase in volume of the fiducial region with very low background.