An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High Performance Mass Spectrometry: FT-ICR at 14.5 T Gregory S. Boebinger, National High Magnetic Field Laboratory DMR 0654118Ion Cyclotron Resonance User Program, Florida State University The schematic diagram shows the NHMFL’s 14.5 Tesla hybrid linear quadrupole ion trapFT-ICR mass spectrometer. Ion masses are routinely determined at four-fold better mass accuracy and two-fold higher resolving power than similar 7 T systems at the same scan rate. External calibration broadband mass accuracy typically less than 300 ppb rms (34 ppb for a single peptide isotopic distribution) and resolving power of 200,000 (m/Δm50% at m/z 400) is achieved at >1 mass spectrum/second. Novel ion storage optics and methodology increase the maximum number of ions that can be delivered to the FT-ICR cell, thereby improving dynamic range for tandem mass spectrometry and complex mixture applications. Schaub, T.M.; Hendrickson, C.L.; Horning, S.; Quinn, J.P.; Senko, M.W. and Marshall, A.G. "High Performance Mass Spectrometry: FT-ICR at 14.5 Tesla," Analytical Chemistry, 80, 3985-3990 (2008).

  2. High Performance Mass Spectrometry: FT-ICR at 14.5 TGregory S. Boebinger, National High Magnetic Field Laboratory DMR 0654118Ion Cyclotron Resonance User Program, Florida State University The improvements in Fourier Transform Ion Cyclotron Resonance (FT-ICR) are transformative, not incremental: mixtures that are unresolved at lower field are resolved at 14.5 T (see the three cockroach peptides). Organic mixtures as complex as petroleum crude oil (up to 50,000 peaks in a single spectrum) can now be resolved and the chemical components identified. Schaub, T.M.; Hendrickson, C.L.; Horning, S.; Quinn, J.P.; Senko, M.W. and Marshall, A.G. "High Performance Mass Spectrometry: FT-ICR at 14.5 Tesla," Analytical Chemistry, 80, 3985-3990 (2008).

More Related