1 / 32

MCT360-T Tobacco Moisture Sensor

MCT360-T Tobacco Moisture Sensor. World’s Leading Supplier of Tobacco Moisture Analyzers. Process Sensors founded in 1996. Over 400 man years experience in tobacco moisture measurement. World Headquarters in Milford, Ma USA.

gala
Download Presentation

MCT360-T Tobacco Moisture Sensor

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MCT360-T Tobacco Moisture Sensor

  2. World’s Leading Supplier of Tobacco Moisture Analyzers • Process Sensors founded in 1996. Over 400 man years experience in tobacco moisture measurement. • World Headquarters in Milford, Ma USA. • Sales and Service Offices in China, Malaysia, North America, UK, and Poland. • Distributors Worldwide.

  3. Worldwide Sales & Service EUROPE Process Sensors EuropeUnit 4, Adelaide HouseCorbygate Business ParkCorby, Northants NN17 5JGUnited KingdomTel: (44) 1536 408066   Fax: (44) 1536 407813infouk@processsensors.com EASTERN EUROPE Process Sensors PolskaBiuro InformacyjneTechniki Pomiarowej 03-980 Warszawa ul. Znanieckiego 16/23 PolandTel:(48) 22 6739526Fax:(48) 22 6739527t_stachowiak@poczta.onet.pl ASIA Process Sensors Asia 40 Jalan RK 3/30 Rasah Kemayan70300 SerembanNegeri Sembilan, MalaysiaTel:+606-6014598Fax:+606-6014588hussin@processsensors.com WORLD HEADQUARTERS Process Sensors Corp.113 Cedar StreetMilford, MA 01757 USATel:508-473-9901Fax:508-473-0715info@processsensors.com

  4. Strong, Stable, Diversified, Privately Held Company

  5. Reasons for Moisture Measurement in Tobacco • Quality Control • Final product moisture • Improved Processing • Dry for storage (no rot) • Wet for handling/cutting (won’t crumble) • Flavoring Control • Flavors are based on %dry weight. • Use %moisture to correct weigh belt.

  6. Tobacco Moisture Is Critical In All Phases Of Processing • Moisture impacts smoking quality, flavor, burn, fill, waste, and machine operation from green leaf threshing to primary processing. • Each operation such as drying, re-moisturizing, rolling, cutting, and conditioning have an optimum moisture level to maximize efficiency.

  7. Tobacco Products • Expanded • Blended Tobacco • Pipe Tobacco • Cigar Filler • Cigar Wrapper • Roll Your Own Tobacco • Whole Leaf • Stems • Reconstituted • Chewing Tobacco • Lamina Strips • Cut Tobacco

  8. Internal Reference (Prime) Beam MCT360-T No Drift Operating Principle Filter Wheel Up to 6 Filters Detector Halogen Lamp External (Product) Beam Sample

  9. MT 360-TTobacco Moisture Transmitter Surface mount board Rear connectors – digital, analog and etherrnet MCT 360-T gauge and touch screen OI

  10. Near Infrared Absorption Curve

  11. Tobacco Blends • Different blends need different calibrations Why ? • Casings/Humectants/Volatiles • Look like water in an oven moisture test • Different Tobacco Types • Different NIR reflectance • Affects every NIR instrument on the market

  12. Different Tobacco Types

  13. MCT360-T Provides Digital Display, Analog Outputs, and Digital Interface

  14. Tobacco Moisture Measurement Locations Leaf Tobacco • Conditioning Cylinders • Silos • Steam and Re-moisturising Cylinders • After Blending • After Cutting • Final Cut Filler Dryer Steam Cylinder Conditioning Storage Silo Burley Tobacco Dryer Flavor Cylinder Conditioning Storage Silo Final Cut Blended Filler To Cigarette Makers Steam Cylinder Storage Silo Flavor Cylinder Reconstituted Tobacco Cutters Blending Expanded Tobacco Remoisten Expansion Chamber Tobacco In

  15. MCT360-T Before Dryer MCT360-T On Conveyor MCT360-T After Cooler

  16. Steam and Water Controller SENSOR SENSOR Tobacco Installation: Steam Cylinder Control Feedback Control Bad! poor mixing Bad! too close to cylinder Feed forward Control

  17. The Intelligent Gauge Concept • Gauge carries out all signal processing • Calibrated measurements derived in gauge head • There is no need for control units • The gauge is a network device • It can communicate with other devices for data display • Inbuilt features, PID Controller, Product Temperature, Humidity Compensation • Single PCB Design

  18. MCT360-T Sensor Performance • Accuracy • Depends on lab, sampling, tobacco type • Strip, Stem & Whole Leaf Tobacco: +/- 0.3% • Cut Tobacco: +/- 0.1% • Reconstituted & Expanded Tobacco: +/- 0.1% • Lamp Life 5-10+ years. • Stability • Excellent: +/- 0.1%/yr • Height Sensitivity • 15-40 cm (6-16”) Excellent

  19. Excellence in Measurement • Backscatter, Single or Multi-Component intelligent NIR gauge • Unrivalled measurement accuracy, stability and capability • high speed measurement offering enhanced accuracy • up to 3 component analysis • Optional IR Product Temperature Measurement • Pre-calibrated measurements • Easy to use, Multi-lingual Operator Interface • Active diagnostics • No Routine Maintenance • Networkable gauge using “AnyBus” communication standards with connectivity to the process. ProfiBus, DeviceNet, Ethernet Etc...

  20. Easier Customer Operation • Multiple Languages including Chinese Selectable by Operator • All sensors have the same span • Same sensor • Detectors have same output characteristics • Same algorithm, filters, settings • Same application, product • Zero is fine-tuned at target to account for local laboratory methods

  21. MCT600-Bench Top Moisture Analyser The MCT-600 is a bench top, multiple constituent tester.  Samples are placed in the sample dish, rotated automatically and tested within 10 seconds.  Reducing sugars and nicotine measurements available on select ground samples. • Rotating Sample Tray • Non Contact Testing • Pre-Calibrated • Multiple Measurements • Multi Language  Display • No Sample Preparation

  22. IndonesiaPT GeloraDjajaPT GandumPT Stefenia Ultra TobaccoPT MartindoInti TobaccoPT Roberta Tobacco Ind. • PT Sampoerna • PT  Indonesia Tri Sembilan • PT NorojonoVietnamDong Nai Tobacco Co.ThanhHoa Tobacco FactoryBangladeshAbu Khair Tobacco Co. LtdNasir Tobacco Industry Among Our Family Of Customers PhilippinesFortune Tobacco   Philippines ThailandThai Tobacco Monopoly  (TTM)  ThailandSouth KoreaKGT  Taiwan Taiwan Tobacco  (TTM)  Feng Yuan Tobacco   Australia Philip Morris  VietnamVietnam Tobacco Corporation   VietnamBangladeshDhaka Tobacco Industries   BangladeshInternational Tobacco (Azizuddin Industries Ltd.)  Bangladesh South Africa United Africa Tobacco East London Cut Rag Processors USA LorrillardPhilip Morris USARJReynoldsAlliance OneRothman'sUniversal Leaf UAE Vision Tobacco

  23. European Tobacco Turkey 8 Japan Tobacco (15) Spain Certesa 1 Greece VIT (OEM) - Various leaf processors Italy (many of these are historical and you may not want to use them) Comas (OEM) Garbuio Man.Tabacchi (8), now BAT if still in existance TAC (was OEM) 6 RJ Reynolds 14 Philip Morris 8 British American Capital 10 • Russia • Imperial Tobacco • Japan Tobacco • Poland • Imperial Tobacco • Ukraine • Imperial Tobacco • Japan Tobacco • Kyrgystan • Imperial Tobacco • Serbia • Japan Tobacco • Republic of Moldova • Tutin • CTC Among Our Family Of Customers Spain Certesa Greece VIT (OEM) Italy Comas (OEM) Garbuio Man.Tabacchi BAT TAC RJ Reynolds Philip Morris British American Capital Belgium Tobacco Nollet. Imperial Tobacco Tabaksfabiek Stubbe Gryson Flandria Neos Vandemarlier Netherlands Imperial Tobacco Heupink + Bloemen Germany Von EickenDHT France Imperial Tobacco Senegal Imperial Tobacco Ivory Coast SITAB Ivory Coast UCAPT,France-Tabac SWM/LTR Sitab Switzerland Japan Tobacco Turkey European Tobacco Turkey Japan Tobacco

  24. PSC Viewer Software • Operates On All PSC Equipment • Calibrate PSC NIR Gauges • Trend On-Line Information • View Gauge Diagnostics • Set Up Sensor Parameters • Store Product Codes • Gauge Networking

  25. PSC Viewer Menus • Set-Up - Allows changes to:- Product Code, Zero, Span, Analogue Range • On-Line - Provides historical trending, data logging and alarms • Products - Product code naming • Calibration - Regression of data and calibration of gauges, upload files • Diagnostics - System analysis • Engineering - Password protected

  26. Service and Support • Full Time Field Service Employees • 24 Hour Response Time • Application Analysis provided at no charge • Pre - Calibration Service • Customer training • Service Contracts

  27. SENSOR How to Grab Samples • Just downstream • In line • From the surface • Many small samples • “USE IN BUILT SAMPLING FACILITY” Flow Direction Grab from Here 13.

  28. Stability Check Procedure • Preparation • 1) Read stability check(s) while the sensor is calibrated. • 2) Record the reference reading. • Test • 1) Make sure the calibration is the same. • 2) Read the stability check(s). • 3) Compare to the reference readings. • 4) A significant difference means a problem.

  29. Calibration Check Standards • Use to verify instrument stability. • How Many ? • 1 check: Good • 2 checks: Better (Span and Zero) Locating Pins PSC Stability Check Rare Earth Glass Passive Reflector Clear Glass Cover

  30. Why PSC ? • True stand alone transmitter • Support network with knowledge • Fast, accurate, reliable measurement • Ease of maintenance • User friendly operation • Cost effective solution • Customer care We want to continue to earn your confidence and your business. Please contact us with any questions.

  31. Process Sensors Corp. 113 Cedar St. Milford, Ma. 01757 USA 508.473-9901 www.processsensors.com

  32. Thank you for your consideration. We will make every effort for project success with strong support after sale.