DDS Data Analysis. Alberto Lobo ICE-CSIC & IEEC. DDS : Data Management & Diagnostics Subsystem. Diagnostics items : Purpose : Noise split up Noise sources for LISA: spot route to required sensitivity Sensors for : Temperature Magnetic fields Charged particles
E N D
DDS Data Analysis Alberto Lobo ICE-CSIC & IEEC DDS Data Analysis
DDS: Data Management& Diagnostics Subsystem • Diagnostics items: • Purpose: • Noise split up • Noise sources for LISA: spot route to required sensitivity • Sensors for: • Temperature • Magnetic fields • Charged particles • Calibration: • Heaters • Induction coils • DMU: • Purpose: • LTP computer • Hardware: • Power Distribution Unit (PDU) • Data Acquisition Unit (DAU) • Data Processing Unit (DPU) • Software: • Boot SW • Application SW: • Diagnostics • Phase-meter • Interfaces DDS Data Analysis
Approach: 1) Apply controlled perturbation a to the system 2) Measure “feed-through” coefficient between force and perturbation: 3) Measure actuala with suitable sensors 4) Estimate contribution of a by linear interpolation: 5) Substract out from total detected noise: 6) Iterate process for all identified perturbations Noise reduction philosophy Problem: to assess the contribution of a given perturbation to the total noise forcefint. DDS Data Analysis
Various diagnostics items • Temperature and temperature gradients: • Sensors:thermometers at suitable locations • Control:heaters at suitable locations • Magnetic fields and magnetic field gradients: • Sensors:magnetometers at suitable locations • Control:induction coils at suitable locations • Charged particle showers (mostly protons): • Sensors: Radiation Monitor • Control: non-existent DDS Data Analysis
General scheme for DDS DA (S2-IEC-TN-3031) • For each diagnostic: • Measurement runs • Controlled disturbance ON (if applicable) • Controlled disturbance OFF • Available data (in each case) • Data Analysis Procedures DDS Data Analysis
Thermal 22 NTC temperature sensors 16 heaters DDS Data Analysis
Thermal DDS Data Analysis
Thermal Optical Window DDS Data Analysis
Heater Thermal Optical Window Heaters DDS Data Analysis
Thermal Optical Bench Temperature Sensors DDS Data Analysis
Thermal Suspension Struts: Heaters and Sensors DDS Data Analysis
t = 1000 sec Heaters signal T1 T2 H1 H2 T3 T4 T1 T2 H1 H2 T3 T4 P Heater set 1 Heater set 2 t t EH heaters: activation scheme Sensors response (CGS SW tool) DDS Data Analysis
Heaters ON: EH Measurements: Temperatures T1, T2, T3, T4 per IS Accelerations a1, a2 per IS Laser Metrology x1, D Main thermal signal: DT=(T1+T3) - (T2+T4) per IS Data Analysis: fit data to Transfer function temperature-acceleration ensues DDS Data Analysis
Heaters ON: OW Measurements: Temperatures T5, T6 in IS1, T11, T12 in IS2 Laser Metrology x1 for IS1, x2= x1+ D for IS2 Thermal signals: temperature closest to activated heater Data Analysis: fit data to ARMA(2,1): • Should be OK in MBW –even beyond!–, and for each OW • Can easily be improved, if necessary, at lower frequencies DDS Data Analysis
Heaters ON: suspension struts Measurements: Temperatures Ti, i = 1,...,6 –all struts Laser Metrology x1 and x2= x1+ D for each case Thermal signals: temperature closest to activated heater Data Analysis: • Transfer function is a 6x2 matrix • Estimated by standard methods • Cross correlations likely to show up (?) • Current shortage of experimental data no sound a priori model available DDS Data Analysis
All heaters OFF • Temperature measurements to be translated into LTP • signals (TM accelerations and/or laser metrology phase shifts) • by transfer function scaling. • Cross correlations between different channels: • Some can be (safely) discarded, e.g. OW-EH, etc. • Others cannot, e.g., among different struts • Global LTP system identification • Some sensor readings used as housekeeping data, e.g., OB • and redundant OW sensors • Improved experimental characterisation needed and underway DDS Data Analysis
Test masses are a AuPt alloy 0.7 Au + 0.3 Pt of low susceptibility a = 46 mm m = 1,96 kg and low remnant magnetic moment: Magnetic disturbances in the LTP • Magnetic noise is due to various causes: • Random fluctuations of magnetic field and its gradient • DC values of magnetic field and its gradient • Remnant magnetic moment of TM and its fluctuations • Residual high frequency magnetic fields DDS Data Analysis
LCA DDS Data Analysis
Magnetometer available areas DDS Data Analysis
Magnetometers’ accommodation DDS Data Analysis
Coil Accommodation DDS Data Analysis
Philosophy: apply controlled periodic magnetic fields: Force comes then a two frequencies: Magnetic diagnostics: coils ON • B0 is calculated rather than measured with magnetometers • Bbg is LTP background magnetic field DDS Data Analysis
Analysis: from above data we can obtain are measured with good SNR (~ 100 max) are measured with poorer SNR Magnetic diagnostics: coils ON • Data: • Laser Metrology x1 and x2= x1+ D for each VE being affected • a1 (a2) from IS1 (IS2) if possible • Coil feed intensity and frequency DDS Data Analysis
Magnetic diagnostics: coils ON From Fx,2w we can estimate c to ~1% From Fy,2w and Fz,2w we get error correction and cross check • Fw can be useful to estimate remnant magnetisation M • This is more complicated, though: • Fx,w has (max) SNR ~ 100, but Fy,w and Fz,w quite less • Yet all three components are needed, as M is a vector • In addition, Mneeds to be disentangled from Bbg DDS Data Analysis
Continuous magnetic field monitor Data: • 4 3-axis magnetometers at fixed positions in LCA • 12 sampled magnetic field channels • Magnetic field and gradient must be known at TM locations: • Magnetometer data streams are fed to suitable extrapolation algorithms • These algorithms are (so far) computationally demanding • To be run offline • They produce a magnetic field + gradient map around TMs • Magnetic map error estimates will be delivered by the algorithm, too • Processed data directly yield magnetic transfer function. • Extrapolation operation errors need tight control. DDS Data Analysis
Magnetic Problem • We need the magnetic field on the TMs region. For this, measuremrents provided by 4 3-axis magnetometers are available. There are (at present) 37 sources of magnetic disurbance identified (ASU). Magentometer information is thus insufficient to reconstruct the magnetic map. • The nominal magnitudes (moduli) of the magnetic moments of the sources are reasonalbly well known moments but their directions are not. DDS Data Analysis
Radiation Monitor From S2-IEC-TN-3031: ...The radiation monitor is primarily designed to help understand and quantify these variable processes [modulations of CGR and fluxes of SEP] by monitoring the external particle fluxes and allowing these to be correlated with the test-mass charge measurements. DDS Data Analysis
Radiation Monitor DDS Data Analysis
Radiation Monitor DDS Data Analysis
Radiation Monitor DDS Data Analysis
Radiation Monitor • Establish the charging-rate in the TMs due to cosmic-ray interactions. Compare with Monte Carlo simulations. Requires a long run with no UV lamps operating. • Establish the cosmic-ray transfer function from the radiation monitor to the test-mass charge. • Establish or limit the level of power spectral density of cosmic-ray modulations caused by solar activity. Provided by continuous operation of RM and other monitors available. • Establish the solar-energetic particle (SEP) flux enhancement distributions (temporal and fluence) seen by the radiation monitor. • Establish the solar-energetic particle transfer function from the radiation monitor to the test-mass charge. Done by cross-correlation of TM charge control data with RM (and other monitors) SEP data. • Estimate the solar-energetic particle induced charging rate and compare with simulations. • Demonstrate the closed loop charge control process and estimate its gain factor. DDS Data Analysis
Radiation Monitor Radiation Monitor data are formatted in a histogram-like form. A histogram is generated and sent (to OBC) every 614.4 sec. DDS Data Analysis
Radiation Monitor • Additional data required: • Test mass charges, Q1 and Q2 every 1000-10,000 seconds to an accuracy to 104 elementary charges with sign. • ULU time status including lamps on/off and commanded UV levels • Inertial sensor noise power spectra • RM calibration data – channel to energy conversion • RM calibration data – efficiency factors for each spectral channel • RM calibration data – spectral resolution as function of energy • Updated satellite geometry model • Solar activity indicators DDS Data Analysis
End of Presentation DDS Data Analysis
Radiation Monitor GCR SEP DDS Data Analysis
Radiation Monitor DDS Data Analysis
Radiation Monitor • Data handling issues: • Front detector hits sent as flags • Coincident events sent as energy deposed • Electronics is able to cope with up to 5000 c/s, • so data compression will be eventually needed. • Testing issues: • Artificially generated pulses • Muon test • Proton source exposition: PSI, end of October DDS Data Analysis