Why would I use YOUR boiler?. Competing with the Cleaver Brooks Clearfire -CFC. Cleaver-Brooks Clearfire-CFC. What are we up against? Stainless Steel Condensing Single pass for water and flue Down fired. Cleaver-Brooks Clearfire-CFC.
E N D
Why would I use YOUR boiler? Competing with the Cleaver Brooks Clearfire-CFC
Cleaver-Brooks Clearfire-CFC What are we up against? • Stainless Steel • Condensing • Single pass for water and flue • Down fired
Cleaver-Brooks Clearfire-CFC • 3 CFC models that compare with Crest – 1.5, 1.8, 2.5 million BTU versions • 5:1 turndown • “Stated efficiencies” up to 99%
Cleaver-Brooks Clearfire-CFC • 316 Ti stainless steel tubes, tube sheets, and furnace. • Patented Alufer finned fire tubes
Why do I want to specify YOUR boiler? • Weight/footprint
Why do I want to specify YOUR boiler? • Weight/footprint • Vent size/ length of run
Cleaver-Brooks Clearfire-CFC Shorter runs with similar size vent
Why do I want to specify YOUR boiler? • Weight/footprint • Vent size/ length of run • Working pressure
Crest gives you a max of 160 psig! Cleaver-Brooks Clearfire-CFC
Why do I want to specify YOUR boiler? • Weight/footprint • Vent size/ length of run • Working pressure • GAS PRESSURE!
Cleaver-Brooks Clearfire-CFC High Minimum Gas Pressures…
Cleaver-Brooks Clearfire-CFC …against Lochinvar’s minimum of 4”!!!!
Why do I want to specify YOUR boiler? • Weight/footprint • Vent size • Working pressure/ • GAS PRESSURE! • Seamless system integration- • Modbus, bacnet, lonworks, smart touch, etc
Look! It says so right here! No Minimum Flow… …or is there?
Cleaver-Brooks Clearfire-CFC • Don’t get hung up on “no flow required” for any of the competitors out there…boilers need flow to remove the heat… • Any boiler can be a no flow boiler…it just won’t turn on!
Why Do I want to buy your boiler? • Color display to aid on site personnel with troubleshooting/ trending/ etc
Why Do I want to buy your boiler? • Color display to aid on site personnel with troubleshooting/ trending/ etc • Piece of mind – third party rated so you know you are getting the efficiency you are paying for
Why Do I want to buy your boiler? • Color display to aid on site personnel with troubleshooting/ trending/ etc • Piece of mind – third party rated so you know you are getting the efficiency you are paying for • Complete SS heat exchanger vs Aluminum flue side surfaces
Why do I want to Install your boiler? HOLD THAT PRICE! • Installed cost – direct vent kit!! Money to buy the kit, time to install it!
Why do I want to Install your boiler? HOLD THAT PRICE! • Installed cost – direct vent kit!! Money to buy the kit, time to install it! • Installed cost - piping – low and high water inputs for “dual temp” systems
Why do I want to Install your boiler? HOLD THAT PRICE! • Installed cost – direct vent kit!! Money to buy the kit, time to install it! • Installed cost - piping – low and high water inputs for “dual temp” systems • Installed cost – vent material!!
Cleaver-Brooks Clearfire-CFC Venting Example: Lochinvar Crest 1.5 Clearfire-CFC 1.5 100 eqiv. ft vent run 8” SS vent material 12” SS vent material Approx cost per foot $114 list x85 ft Approx cost per foot $131 list x85 ft $230 per elbow x3 elbows $258 per elbow x3 elbows . $10,380 $11,909 That’s an 11.5% savings!
We’ll Take it! We’ll Take it! We’ll Take it!