THE AUTOMATIC PROCESSOR

THE AUTOMATIC PROCESSOR. AUTOMATIC PROCESSOR DAYLIGHT SYSTEM. PROCESSOR. SECTIONS OF THE PROCESSOR. D. F. W. D. FEEDING FILM INTO THE PROCESSOR. PROCESSOR. FEED TRAY. MICROSWITCH. ENTRANCE ROLLERS. ENTRANCE ROLLER. ENTRANCE ROLLER. FILMS ORIENTATION ON THE TRAY. 14 X 17 11 X 14

gay-morrow
Download Presentation

THE AUTOMATIC PROCESSOR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THE AUTOMATIC PROCESSOR

  2. AUTOMATIC PROCESSOR DAYLIGHT SYSTEM

  3. PROCESSOR

  4. SECTIONS OF THE PROCESSOR D F W D

  5. FEEDING FILM INTO THE PROCESSOR PROCESSOR FEED TRAY

  6. MICROSWITCH

  7. ENTRANCE ROLLERS ENTRANCE ROLLER ENTRANCE ROLLER

  8. FILMS ORIENTATION ON THE TRAY 14 X 17 11 X 14 10 X 12 8 X 10 7 X 17

  9. FILM

  10. FILM

  11. FILM FILM

  12. PROCESSOR SYSTEMS & SUBSYSTEMS • TRANSPORT • TEMP. CONTROL • RECIRCULATION • REPLENISHMENT • DRYER • ELECTRICAL

  13. TRANSPORT TRANSPORT FILM THROUGH PROCESSOR, REGULATION OF IMMERSION TIME, AGITATE SOLUTIONS

  14. ROLLERS TRANSPORT RACK DRIVE MOTOR TRANSPORT SYSTEM SUBSYSTEMS

  15. ROLLERS-PROPEL THE FILM

  16. TRANSPORT RACKS-HOLD ROLLERS AND GUIDE SHOES

  17. DRIVE MOTOR—POWER FOR MOVEMENT OF ROLLERS

  18. TRANSPORT GUIDE SHOE ROLLER RACKS

  19. TRANSPORT ROLLER ASSEMBLYPLANETARY ROLLERS

  20. TURNAROUND ASSEMBLY MASTER GUIDE SHOE

  21. TURNAROUND ASSEMBLY MASTER ROLLER GUIDE SHOE SQUEEGE ROLLER

  22. TEMPERATURE CONTROL—DRYER AND SOLUTION TEMPERATURE ELECTRICAL HEATER

  23. TEMPERATURE MEASUREMENT ACCURATE TO +-0.5º F DO NOT USE: MERCURY OR ALCOHOL THERMOMETRS!

  24. DEVELOPER FIXER WASH DRYER 95 DEG F +-0.5º 95 DEG. F +- 5º 95 DEG. F +- 5 º 135 DEG. F TEMPERATURE

  25. TEMP. CONTROL

  26. DRYER TEMP. RECIRCULATION DRYER BLOWER

  27. RECIRCULATION –AGITATION OF SOLUTIONS+ FILTRATION FILTER PUMP

  28. RECIRCULATION

  29. CIRCULATION OF WATER THROUGH WASH TANK---3 GALLONS/MIN. ( 12 LITERS/MIN.)

  30. REPLENISHMENT SYSTEM

  31. REPLENISHMENT D F REPLENISHMENT PUMP

  32. REPLENISHMENT RATESFOR EVERY 14 IN. OF FILM • 60-70 ML OF DEVELOPER • 100-110 ML OF FIXER VARIATION: +- 5%

  33. PROCESSING TIME • 45 SEC-210 SEC. • MOST PROCESSORS DROP TIME 90 SEC. VARIATION: +- 2-3%