1 / 23

Panasonic KX-TDA200/100 System (Production Version 2.02)

This is the office network edition of the Panasonic KX-TDA200/100 system. It provides a range of system capacity and resources for telephone and PBX selections.

gbaney
Download Presentation

Panasonic KX-TDA200/100 System (Production Version 2.02)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KX-TDA200/100 System(Production Version 2.02) Panasonic Communications Co., Ltd. Office Network Company Edition 1.0 31 May, 2006 Chapter 1System Capacity and System Resources

  2. Index 1. System Capacity 2. System Resources

  3. Function 1. System Capacity

  4. 1.System Capacity(1/14) Full free slot for TDA100/200 < Card (1/3) > OLD NEW (Ver.3) Line Type TDA100 TDA200 Line Type TDA100 TDA200 Trunk Trunk 4 8 6 8 Extension 4 8 Extension 6 8 Total 5 10 Total 6 11 free slots 1 to 10 free slots 1 to 11 free slots 1 to 5 free slots 1 to 6

  5. 1.System Capacity(2/14)

  6. 1. System Capacity(3/14) < Card (2/3)> TDA100 Old Card Type New Max. 2 PRI, E1, T1, IPGW, CSIF Max. 4 Max. 2 cards for PRI/E1/T1/IPGW/CSIF Max. 4 cards for PRI/E1/T1/IPGW/CSIF New Old

  7. 1. System Capacity(4/14) < Card (3/3)> TDA30 Old Card Type New E1 Yes No

  8. 1.System Capacity(5/14) < Port > TDA100 w/o MEC(1/2) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 LCOT16 Cell Station for DLC/DHLC card 0 Slot 4 LCOT16 Cell Station for CSI/F card 0 Slot 5 LCOT16 IP-PT * 0 Slot 6 LCOT16 SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-S Total Power Factor : 64 PSU Type : Not Required Total PT+SLT : 64 MEC Card : Total:64+64=128 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  9. 1.System Capacity(6/14) < Port > TDA100 w/o MEC(2/2) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 PRI Cell Station for DLC/DHLC card 0 Slot 4 PRI Cell Station for CSI/F card 0 Slot 5 PRI IP-PT * 0 Slot 6 PRI SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-S Total Power Factor : 64 PSU Type : Not Required Total PT+SLT : 64 MEC Card : Total:64+120=184 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  10. 1.System Capacity(7/14) < Port > TDA200 w/o MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 DLC16 APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 LCOT16 LCOT16 IP-PT * 0 Slot 6 LCOT16 SLT * 0 Slot 7 Slot 8 LCOT16 LCOT16 Total Port Number of KX-TV (DPT Integration) Slot 9 Slot10 LCOT16 First VM Unit 0 CH 0 Slot11 LCOT16 Second VM Unit 0 CH 0 *) PSU type is not effect by SLT/IP-PT numbers. Result Power-M Total Power Factor : 128 PSU Type : Not Required Total PT+SLT : 128 MEC Card : Total:128+112=240 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  11. 1.System Capacity(8/14) < Port > TDA200 w/o MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 DLC16 APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 PRI PRI IP-PT * 0 Slot 6 PRI SLT * 0 Slot 7 Slot 8 PRI Total Port Number of KX-TV (DPT Integration) Slot 9 Slot10 First VM Unit 0 CH 0 Slot11 Second VM Unit 0 CH 0 *) PSU type is not effect by SLT/IP-PT numbers. Result Power-M Total Power Factor : 128 PSU Type : Not Required Total PT+SLT : 128 MEC Card : Total:128+120=248 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  12. 1.System Capacity(9/14) < Port > TDA100 with MEC(1/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 IP-EXT16 IP-PT * 32 Slot 6 IP-EXT16 SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-M Total Power Factor : 128 PSU Type : Required Total PT+SLT : 160 MEC Card : Total:160+0=160 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  13. 1.System Capacity(10/14) < Port > TDA100 with MEC(2/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 LCOT8/16 IP-PT * 0 Slot 6 LCOT8/16 SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-M Total Power Factor : 128 PSU Type : Required Total PT+SLT : 128 MEC Card : Total:128+32=160 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  14. 1.System Capacity(11/14) < Port > TDA100 with MEC(3/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 PRI IP-PT * 0 Slot 6 PRI SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-M Total Power Factor : 128 PSU Type : Required Total PT+SLT : 128 MEC Card : Total:128+60=188 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  15. 1.System Capacity(12/14) < Port > TDA100 with MEC(4/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 APT 0 Slot 3 PRI Cell Station for DLC/DHLC card 0 Slot 4 PRI Cell Station for CSI/F card 0 Slot 5 PRI IP-PT * 0 Slot 6 PRI SLT * 0 N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Power-S Total Power Factor : 64 PSU Type : Not Required Total PT+SLT : 64 MEC Card : Total:64+120=184 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  16. 1.System Capacity(13/14) < Port > TDA200 with MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 DLC16 APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 DLC16 DLC16 IP-PT * 0 Slot 6 DLC16 SLT * 0 Slot 7 Slot 8 DLC16 LCOT Total Port Number of KX-TV (DPT Integration) Slot 9 Slot10 LCOT First VM Unit 0 CH 0 Slot11 LCOT Second VM Unit 0 CH 0 *) PSU type is not effect by SLT/IP-PT numbers. Result Power-L Total Power Factor : 256 PSU Type : Required Total PT+SLT : 256 MEC Card : Total:256+48=304 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  17. 1.System Capacity(14/14) < Port > TDA200 with MEC(2/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128 Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16 DLC16 APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 DLC16 DLC16 IP-PT * 0 Slot 6 DLC16 SLT * 0 Slot 7 Slot 8 DLC16 PRI Total Port Number of KX-TV (DPT Integration) Slot 9 Slot10 PRI First VM Unit 0 CH 0 Slot11 PRI Second VM Unit 0 CH 0 *) PSU type is not effect by SLT/IP-PT numbers. Result Power-L Total Power Factor : 256 PSU Type : Required Total PT+SLT : 256 MEC Card : Total:256+90=346 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

  18. Function 2. System resource

  19. 2.System Resources (1/4) TDA100/TDA200 Old Resources New 32 Network DSS Key(TDA0920) 250 80 (4 digits) Quick Dial 80 (4 digits) 80 (4 digits) Quick Dial with MEC card 80(4digits)+4,000(8digits) 128 64 ICD Group ICD Group Member 32 32 ICDG Member(sales C mode) 128 TDA30 Quick Dial with MEC card 80(4digits)+1,000(8digits) 80 (4 digits)

  20. 2.System Resources (2/4) TDA0920 is required. Network DSS Key Network Data Transfer NDSS Key Table Network PBX ID up to 8 NDSS up to 250

  21. 2.System Resources (3/4) Quick Dial expansion Quick Dial With MEC Basic Memory MEC Memory Up to 80 without MEC Up to 4,000 with MEC

  22. 2.System Resources (4/4) Sales Company Level ICD Group expansion Miscellaneous Enable 128 extensions ICD Group ICD Group Member 128 ICD groups 128 extensions

  23. Chapter 1System Capacity and System Resources Thank you very much !