1 / 61

National pollutant release and transfer register in poland data management

National pollutant release and transfer register in poland data management. Justyna Grzywacz Chief Inspectorate of Environmental Protection 4 th November,2011. Outline of the presentation. Collecting the data Data verification Data quality improvement Publication of the data

gerik
Download Presentation

National pollutant release and transfer register in poland data management

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nationalpollutantrelease and transfer register in polanddata management Justyna Grzywacz ChiefInspectorate of EnvironmentalProtection 4th November,2011

  2. Outline of thepresentation • Collecting the data • Data verification • Data qualityimprovement • Publication of the data • PRTR database – work on data

  3. Collecting the data POL-PRTR on-line system • Registration → facilityidentification • Log in → on-line report

  4. Collecting the data Note: consider only an electronic version of the report Poland is only country in EU, which requires from operators report in 2 versions. In case of not enough access to internet a good practice it to enable the operators report by using the computer in regional environmental agency.

  5. Data verification Two levels: • Voivodship Inspectorate of Environmental Protection; • Chief Inspectorate of Environmental Protection

  6. Data verification Voivodship of EnvironmentalProtection: • comparing with other data from differentreporting; • inspection on the facility; • analyse of the availabledocuments: permits, wastes transfer card;

  7. Data verification ChiefInspectorate of EnvironmentalProtection by using the validationtool (EC): • mostlychecks the correctness of the xml file → lack of data; • correctness of the data itself

  8. Data verification -VoivodshipInspectorate’slevel • facilities from the specificvoivodshiponly; • filtering thedata by: • district; • Borough; • thename of the facility; • REGON - statisticalnumber • ID number; • Login of the facility; • City; • the last report status

  9. Data verification- VoivodshipInspectorate’slevel • main options: • show reports (detailslater) • change the password; • delete; • status of the facility: not under the PRTR Regulationanymore and determine the economicactivity (highlighted by differentcolor); • changing the identification data (detailslater)

  10. Data verification- VoivodshipInspectorate’slevel Show reports: • Set feedback→ usedwheninspectorfindsany error in the report • Archive the report → allreportswhichare not correct (showed as „T” (yes) or „N” (no)); • Show the details → view of the report; • Delete the report → whenaccidentallysendorsendmorethanones

  11. Data verification- VoivodshipInspectorate’slevel • Status of the report: • Indefinite – new report • Source – operator sent a signed printout of report (administrator change status); • To correct – report is wrong. Administrator should inform the operator that he has to improve his report(administrator write the feedback in the same time); • Source – signed – it’s a destination status of each report. It means thatreport was checked and it’s correct. Onlyreports with that status are submittedto European Commission.

  12. Data verification- VoivodshipInspectorate’slevel Changing the identification data: • Locationor main economic activity (Annex I of 166/2006 Regulation) →a new facility in PRTR database(newregistrationrequired) • Other data,for example: operator, name of the facility, parent company→the same facility in PRTR database(updating on the system required)

  13. Data verification- VoivodshipInspectorate’slevel Changingthe identificationdata: • Operator → aninformation to inspectorof VoivodshipInspectorate Inspector: • Archive previous data → save for specificyear • Update the data on the system

  14. Data verification- VoivodshipInspectorate’slevel New facility→ differentcolor • checkingthe correctness of the identification data (registration form) → whether the facility is under PRTR obligations • login (given by the system authomaticly) and password (alsogiven by the system, but need to be change) foroperator by e-mail or telephone

  15. Data verification- chiefInspectorate’slevel • the same rights as voivodshipinspector • someadditional: • ID number → required on EC report; • users management → creating a newaccount/login and the password for inspectors of VoivodshipInspectorates; • generating the EC report → anxml file; • dictionary (allunrolledlists)

  16. Data verification – data qualityimprovement • correction of the single report → secondverification (voivodship/chiefinspector) → changing the status in POL-PRTR on-line system → archive the previous report • as manycorrections as needed • allcorrectedreports → EC

  17. Publication of the data • www.prtr-potral.gios.gov.pl • based on EPER site (replaced by E-PRTR site); • pollutantreleases and transfers and waste transfer → from 2007 -2009; • searching by: • pollutant; • industrial activity; • facility level