160 likes | 267 Views
VELO2 Full Metrology. Girish Patel University of Liverpool 16/11/12. Each fiducial made of 4 circles, centre of each was measured. Measure 5x4 = 20 fiducial points, plus 8 more over surface of silicon. Measure all upstream sensors on all modules, then all downstream.
E N D
VELO2 Full Metrology Girish Patel University of Liverpool 16/11/12
Each fiducial made of 4 circles, centre of each was measured Measure 5x4 = 20 fiducial points, plus 8 more over surface of silicon. Measure all upstream sensors on all modules, then all downstream. This means that R and Phi sensors are alternately measured G. D. Patel, University of Liverpool
Take all measured points (almost 1300) and plot the Z value versus measurement number for ALL measurements. Measurements on a single silicon plane should all have same Z, then jump by separation between modules to next silicon plane. All upstream planes followed by all downstream planes explains the overall structure of the plot. However, quite a few anomalies, from single rogue points in a group of 28 to several points, differing by fractions of mm to 30mm! Executive Summary – Data as it stands is not useable G. D. Patel, University of Liverpool
Sensor pairs on a module are separated by ~2mm. Measurements do not match cf -767 and -734, are co-ordinate systems changed during measurements? VELO A-side Points with incorrect z Missing sensor at z=-36 -37 Point Measurement Number LHCb Z-value -277 -467 -434 -617 -584 -667 -634 -684 -717 -734 -767 G. D. Patel, University of Liverpool
VELO C-side Points with incorrect z Missing sensor at z=139 G. D. Patel, University of Liverpool
I then ordered the measurement by the mean Z per plane and calculated dZ between adjacent planes. This should be the z-separation between silicon planes on a module (~2mm)alternating with the separation between modules nominally 30, 50, 150 and 160mm. In other words this mixes up the upstream and downstream measurements. This should not matter if the co-ordinate reference frame is unchanged over all measurements. G. D. Patel, University of Liverpool
VELO2-C Separation between modules ~30, 50, 150, 160 Missing plane OR Z mismatch Expected separation on a module G. D. Patel, University of Liverpool
VELO2-A Separation between modules ~30, where are others Missing plane OR Z mismatch Odd separation on a module Expected separation on a module G. D. Patel, University of Liverpool
R fids symmetric Each fiducial made of 4 circles, centre of each was measured I calculate a mean x,y,z for each of the five fiducials on each sensor from the four centres I then calculate the mean x,y,z of the five fiducials and arrive at a set of numbers for each sensor. The nominal expected values are given in table above. With the VELO1 metrology the coordinate system of the metrology was very close to the LHCb system with x=y=0 at the centre of the silicon. The mean fiducial position could therefore be compared with the nominal designed average fiducial position and this is shown in the next slide and matched reasonably well. G. D. Patel, University of Liverpool
VELO1 C-side Expect -20.90 Expect -20.85 Expect 0.6 Expect 0.0 Expect -0.6 G. D. Patel, University of Liverpool
Z planarity Calculate STDEV of all Z measurements on a silicon plane. Zero if silicon flat AND vertical. A-side mean = 0.063 C-side mean = 0.036 Outliers have points that differ in z by ~0.5mm! VELO1 Mean RMS 0.044 below. G. D. Patel, University of Liverpool