1 / 9

From Chapter 9 of Saunders and Miodownik ’ s CALPHAD book Computational methods

From Chapter 9 of Saunders and Miodownik ’ s CALPHAD book Computational methods. for many years: equil const used to express (the abundance of certain species) in terms of the amounts of other arbitrarily chosen species for one rxn → one equil const needed

gin
Download Presentation

From Chapter 9 of Saunders and Miodownik ’ s CALPHAD book Computational methods

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. From Chapter 9 of Saunders and Miodownik’s CALPHAD bookComputational methods

  2. for many years: equil const used to express (the abundance of certain species) in terms of the amounts of other arbitrarily chosen species for one rxn → one equil const needed the # of rxn ↑ → many equil const needed but not available ∴ CALPHAD (CALculation of PHAse Diagram) method: considering the G energy of all phases → true equil calculation by of phase component → then, the # of unknowns considerably reduced in comparison to equil const approach

  3. in the case of binary and ternary phase equil → analytic method is possible to calculate certain 2-phase equil ex) binary eutectic, negligible solubility in the terminal solid phase, ideal mixing in the liq, equil btw liq and a(A) : Fig. 9.1. Simple eutectic system with ideal mixing in the liquid and negl solid solubility in the terminal solid phases, a and b. Fig. 9.2. G/x diagram at 850K for eutectic system in Fig. 9.1.

  4. no solubility this is a special case  not a good method

  5. general method: equil btw a solu phase & stoichiometric according to Hillert, how to calculate T ? general solution : a liq, liquidus of Φ (MTDATA used this methodology) Newton-Raphson method: for fixed xiΦ → first choosing arbitrary T → iteratively stepping T until ΔG below a small, defined accuracy limit

  6. liq a xa xo xl liq a xia • a more general case of both phases with a solubility range  as xiΦ is not fixed, by fixing T and then finding xa and xliq from xo (To), however, it is converted to N in this section the alloy first assumed in single-phase a → an arbitrary amount of liq introduced → min G reached →fixingliq comp and changing a→ min G reached again → final minimization of G if the alloy chosen outside 2-phase equil (xia) → xiliq calculated to minimize G of a +l → by fixing xiliq and changing the amount of a → G ↓ → finally reaching equil btw a and liq

  7. multi-component sys calculation must be defined: # of degree of fredom reduced G of the sys calculated some iterative tech to minimize G how to reduce f (= v) : by defining a series of constraints such as balance in ionic sys composition range of each phase one of the earliest example of G minimization by White (1958) → chem equil in an ideal gas mixture of O, H, N with the species H, H2, H2O, N, N2, NH, NO, O, O2, OH # of atoms of element j (O, H, N only) in species (H, H2, H2O, NH, NO…)

  8. → presenting 2 methods of G minimization the typical one is to use Lagrange’s method of multipliers: irrespective of # of phases and components here, finding NΦ(fraction or amount of each phase), xkΦ(mole fraction of k in the phase Φ) which minimize G  this is the equil calculation Then, why this method ? with the constraints of ∴ by defining 0 0

  9. # of p eq # of c eq # of p x c eq # of p eq adding ∑0·mk + ∑0·lΦ to the original eq not changing its value → minimum condition of L ? thus, to solve 2p + c (p+1) non-linear eq by the Newton-Raphson method Germany SOLGASMIX  ChemSage  FactSage Canada  FACT  FactSage Sweden Thermo-Calc England MTDATA Germany, MPI Lukas program

More Related