420 likes | 623 Views
An RF photogun for external injection of electrons in a Laser Wakefield Accelerator. Seth Brussaard. People. Xavier Stragier Marnix van der Wiel ( AccTec ) Willem op ‘t Root Jom Luiten Walter van Dijk Seth Brussaard Walter Knulst (TUDelft) Fred Kiewiet
E N D
An RFphotogun for external injection of electrons in a Laser Wakefield Accelerator Seth Brussaard
People Xavier Stragier Marnix van der Wiel (AccTec) Willem op ‘t Root Jom Luiten Walter van Dijk Seth Brussaard Walter Knulst (TUDelft) Fred Kiewiet Eddy Rietman Bas van der Geer (Pulsar Physics) Ad Kemper Marieke de Loos (TU/e & Pulsar) Harry van Doorn Iman Koole Jolanda van de Ven
Outline • Laser Wakefield Acceleration • External Injection • RF Photogun Design • RF Photogun Performance
Laser Wakefield Acceleration Accelerating Fields: 100-1000 GV/m
Injection max 1000 min 10 - 0
External Injection How many electrons can we get in? What will come out?
Setup Incoming laser pulse: 300 mJ, 200 ps , 800 nm Compressed laser pulse: 150 mJ, 50 fs, 800 nm UV-pulse for photogun: 266-400 nm Plasma channel RF- photogun Solenoid (focusing electron bunch) Parabolic mirror 1.2 meter
RF Photoguns Our approach: • Emittance growthdue to non-linearaccelerationfields: • full cylindricalsymmetry • notuningplungers • on-axis RF coupling single-diamondturning
RFPhotogun Coaxial S-band input coupler: scaled down version L-band design DESY
RF Photoguns Approach: • Emittance growthdue to non-linearaccelerationfields: • full cylindricalsymmetry • notuningplungers • on-axis RF coupling single-diamondturning 2nd generation: • Elliptical irises • Highest field strength on cathode; • Cavity parts are clamped, not braized • Easily replaced; • Copper cavity inside stainless vacuum can.
RF Photoguns Clampedconstruction: cavityparts first (half) cell cathode plate second cell
RF Photoguns Clampedconstruction: cavityparts single-diamond turning
RF Photoguns Clampedconstruction: cavityinsidestainless steel vacuumcan
RFPhotogun Cavitymountedinsidemainmagnet:
RF Photoguns RF characterization: resonances f0=2.9980 GHz p-mode f0=2.9918 GHz 0-mode
RF Photoguns RF characterization: onaxisfield profile
RF Photoguns High power RF commissioning: • 80 MV/m at cathode (after one month of training) • Still occasional breakdown • 3 MeV electrons • QE ≈ 3·10-5→ bunch charge Qmax≈ 300 pC Conclusion: clamping is OK! ZFEL Workshop
RF Photoguns • Water cooling for 1 kHz PRF • Presently operating @ 100 Hz (limited by Modulator/Klystron) ZFEL Workshop
Emittance Quadrupole scan:
Emittance Quadrupole scan: Q = 5 pC σx,cathode= 0.43 mm εn = 0.40(5) mm·mrad
The RF photogun: 2.5 Cell RF power 266nm, 50fs Injector for Laser Wakefield Acceleration Three coupled pillboxes Resonant frequency of 2998 MHz RF power source: 10 MW peak power klystron Electron source: Photo-emission from cavity wall E-bunch
Setup Incoming laser pulse: 300 mJ, 200 ps , 800 nm Compressed laser pulse: 150 mJ, 50 fs, 800 nm UV-pulse for photogun: 266-400 nm Plasma channel RF- photogun Solenoid (focusing electron bunch) Parabolic mirror 1.2 meter
Beamline correction coils RF pulsed solenoid Faraday cup spectrometer 266nm 50fs phosphor screen
Bunch Energy spectrometer E = 3.71 ± 0.03 MeV 1 Intensity (a.u.) 0.5 0 3.61 3.67 3.73 3.79 σ Energy (MeV) = 2 keV Emax
Spot Size pulsed solenoid 700 εn~ 1-3 mm·mrad. 600 500 400 RMS Radius [μm] 300 200 100 0 0.0 0.1 0.2 0.3 0.4 focal length [m]
Spot Size & Stability pulsed solenoid 1 mm 0.75 mm
Focus Stability 300 μm 100 μm
Spot Size & Stability pulsed solenoid 20 15 10 Counts 5 0 -12 -6 0 6 12 -12 -6 0 6 12 1 mm ΔX centre focus [μm] ΔY centre focus [μm] 0.75 mm
Simulations focus 20 mm inside plasma focus at entrance of plasma Einj = 3.71 MeV Plaser = 25 TW Eout = 900 MeV
Simulations focus 20 mm inside plasma focus at entrance of plasma Einj = 3.71 MeV Plaser = 25 TW Eout = 900 MeV
Simulations focus 20 mm inside plasma focus at entrance of plasma Einj = 3.71 MeV Plaser = 25 TW Eout = 900 MeV
Simulations focus 20 mm inside plasma focus at entrance of plasma Einj = 3.71 MeV Plaser = 25 TW Eout = 900 MeV
Simulations focus 20 mm inside plasma focus at entrance of plasma Einj = 3.71 MeV Plaser = 25 TW Eout = 900 MeV
External Injection How many electrons can we get in? What will come out? 1 pC @ 3.7 MeV @ 25 TW: 8 fs bunch 900 40 MeV
Conclusions & Outlook RF Photogun as external injector feasible ~ 1 pC accelerated bunches realistic Next: Condition to 6.5 MeV Inject behind the laser pulse
Timing Coherent Transition Radiation (CTR) CTR: radiallypolarized
Bunch Length THz power & energy in focus Q = 70 pC τbunch < 2 ps
Timing Coherent TransitionRadiation (CTR) RF phase 100 fsjitter