1 / 36

THE INTRODUCTION for RF DIATHERMY DEVICE

THE INTRODUCTION for RF DIATHERMY DEVICE. Lavatron LVT-250 LVT-100. JAN. 12, 2009. What is RF diathermy?. Over 100KHz (High Frequency Current, HFC) Same as Radio Frequency Range → Radio Frequency → RF. Lavatron 420KHZ. RF diathermy History. 1886 Development of Radio Frequency Device.

glenna
Download Presentation

THE INTRODUCTION for RF DIATHERMY DEVICE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THE INTRODUCTION for RF DIATHERMY DEVICE Lavatron LVT-250 LVT-100 JAN. 12, 2009

  2. What is RF diathermy? Over 100KHz (High Frequency Current, HFC) Same as Radio Frequency Range → Radio Frequency → RF Lavatron 420KHZ

  3. RF diathermy History 1886 Development of Radio Frequency Device 1897 Approve the effect of Radio Frequency for Diabetes, Obesity 1899 Report the generating of heat in body tissues by passing RF 1906 Study for the break of tumor tissue by RF 1930 RF diathermy device development

  4. Various RF Device RF Tumor Coagulation RF Lesion Generator Short wave(10MHz) Diathermy device Physiotherapy Diathermy Treatment

  5. Monopolar electrode Patient plate RF diathermy Principle → Activation of Ion movement inside of body Transformation of Over 100KHz inside body → → Generate Core body temperature 40~50°C and 3~5CM depth Collision between Ion

  6. + Pole RF diathermy Principle Monopolar Type - Lavatron 420 KHZ = Ion inside of body moves 420,000 times movement / sec - Pole • Current flows between two poles (Electrode and Patient plate). • Electrode is “+ Pole” and Patient plate is “– Pole”. Current flow from Electrode(+ Pole) to Patient Plate(- Pole). • In the mono polar, heat is generated in the deepest side of body comparing bipolar and tripolar type.

  7. Monopolar Type - Lavatron • It needs separate patient plate and electrode (one is electrode (+pole) and the other is patient plate (-pole)) and current flows between two poles. So the depth of penetration is the deepest among three type of RF. • The generated heat damages the old collagen and accelerates the regeneration of new collagen by improved metabolism and supplying new nutrition on the body through RF treatment. • Heat penetrates to the demise area so it melts the cellulite. It is effective to remove fat inside of the body as well. • With this strong effect on body and face, you can expect visible result right after treatment in your body and face.

  8. Bipolar Type • + pole and – pole are in one electrode. • RF current flows between two poles like above picture. So the patient plate is not required. • The depth of penetration is fixed and limited to approximately half of the distance between the two poles. • This means, less energy of sufficient density reaches the deeper skin layers, rendering a more superficial effect regardless of the emitted energy level. • It is effective on face to remove wrinkle and tightening but it can not touch the fat cell so it is not effective on body.

  9. Tripolar Type • One + pole and two – poles are in one electrode. • RF current flows between 3 poles. So current flows between three poles and the penetration depth is a little bit deeper than bi-polar but its depth of penetration is shallower than mono polar RF. • It touch on superficial area on the skin like bi polar RF. Its basic electricity principle is same with bipolar. With this reason, its result is also similar with bi polar. It is effective on face treatment but it is hard to expect good effect on the body especially removing cellulite.

  10. HYPERTHERMIA Lavatron CET Capacitive Electrode Transfer Non conductive electrode INDUCED CURRUNT –Guaranty the Safeness Go into 3 to 5cm depth deep and wide part, Good for skin and body care, pain relief RET Resistive Electrode Transfer Conductive electrode Direct CURRUNT – Go into deep but narrow part Dangerous for burn and damage organ. For physical therapy, need high power

  11. Biological effect of RF Diathermy Increasing core body temperature up to 40~50℃ Expansion of artery and capillary Increasing blood flow rate Increase in O2 supply Increase in Nutrition supply Stimulation of Immune system Increase in Metabolism Removal of Waste material ↓ ↓ ↓ Body Fat combustion Collagen Re composition Obesity Care Treatment good for Beauty as well as Health

  12. MAIN APPLICATIONS LIFTING BODY SHAPING HAIR RESTORTION WRINKLE REMOVING PAIN CONTROL FAT CONTROL

  13. RF Diathermy Body care part Body Fat Decomposition Cellulite Dissolving Size Decreasing Lifting Remove Stretch Marks Abdominal fat care Size decreasing Abdominal fat care Before Abdominal fat care After

  14. Meso-therapy Endermology Cool Pack Lavatron Treatment Way -BODY Synergy effect: Lifting, Sliming,

  15. RF Diathermy treatment - Skin care Part Skin Reproduction Improvement Wrinkle removing Relaxing stressed facial muscle Stimulating Collagen lay Dissolving Melanin pigment Acne treatment by sebaceous glands Facial size decreasing Dark circle treatment Crow’s feet removing Collagen structure before treatment Collagen structure after treatment

  16. SKIN Collagen re composition Lavatron Treatment Aging

  17. Meso-therapy Vitamin C Cool Pack Lavatron Treatment Way - FACE Synergy effect: Lifting, Sliming, Anti Aging Synergy effect: Whitening, Anti Aging

  18. Improvement of Crow’s feet Lavatron Effect (Before & After) for Face Improvement of Acne Improvement of Nasal folds Improvement of Age spot

  19. After 1 session treatment for 10 min. –40 times magnified image Crow’s Feet

  20. After 1 session treatment for 10 min. – 40 times magnified image Forehead

  21. Medical application of RF Diathermy Heat’s deep penetration into tissue Relaxing stressed muscle by overwork and bad position Pain Relief Shoulder pain Lumbar pain Application *Chronic arthritis *Muscle pain *Lumbar pain *Rheumatic arthritis *Frozen shoulder Rheumatology

  22. Before After RF Diathermy treatment - Hair Care Part Supplying Oxygen to scalp Stimulating hair root Sterilization Application • Prevent alopecia, Hair growth, Seborrheic scalp care

  23. Hair and Demodex Hair scarp Demodex Damage hair root, Eat the nutrient material

  24. Special feature of Diathermy Device Lavatron Guaranty the most safe and effective treatment with below unique feature Auto temperature control function (Patent number: 20-397295) Treatment lesion monitoring function (Patent number: 20-397295) Timer function Various electrode for each treatments

  25. 100mm 80mm 70mm 60mm 50mm 40mm 30mm 20mm Standard ACCESSARIES

  26. Optional ACCESSARIES • Pain Relief Electrode • Put the ceramic electrode on the body • without moving. • Effective for • 1) Muscle Relaxation, Pain Relief • 2) Promote blood Circulation • 3) Increase the metabolism • 4) Mind Relaxation • 5) Discharge toxin and body wastes • 6) Make the skin shining with health • 7) Save the labor for rubbing

  27. Optional ACCESSARIES • Hair Electrode • Press the hair electrode around 5 seconds • on the hair scalp. It is the unique electrode • for hair scalp • Effective for • 1) Accelerate blood circulation • 2) Increase air supply on the hair scalp • 3) Increase hair cream absorption rate • 4) Kill the demodex • 5) Physical massage effect • 6) Evenly supply RF on the hair scalp in • between of hair with 24 points

  28. Various electrodes

  29. SPECIFICATION 420KHZ

  30. LVT-100 Accessories

  31. LVT-100 Application: Stimulates collagen layer -> Remove fine wrinkle, Increase skin elasticity, Reduce pore size, Lifting Reduce acne scar and remove acne Reduce age spot • Benefit: • No pain, no side effects • Remarkably safe and effective for all skin types • No aftercare service required

  32. Auto temperature control function (Patent number: 20-397295) Special feature of Diathermy Device LVT-100 Temperature setting: 37℃~45℃ Treatment lesion monitoring function (Patent number: 20-397295) Timer function Five kinds of electrode for treatments

  33. Special feature of Diathermy Device LVT-100 Error message be displayed in the LCD window when the below case is occurred

  34. SPECIFICATION LVT-100

  35. RF body cream - Caffeine: Body fat combustion, Body care - Aloe liquid: High Skin Moisture effect, Increase metabolism RF conductive cream RF Face care cream - Retinol: Wrinkle improve - Adenoisine: Increase elasticity of collagen fiber - Aloe liquid: High Skin Moisture effect`

  36. Export 20 countries Europe *Italy *Spain *Portugal *Poland *Turkey *Russia *Slovenia Under Process Asia *Hong Kong *Thailand *Myanmar Singapore Malaysia Japan China Indonesia Taiwan Kazakhstan *U.S.A *Mexico *Canada *Guatemala Middle East *Iran *Egypt U.A.E *: Exclusive Distributor