Noise Reduction Of Si x Ge 1-x and Si x Ge 1-x O y Bolometers by Forming Gas Passivation

Noise Reduction Of Si x Ge 1-x and Si x Ge 1-x O y Bolometers by Forming Gas Passivation. Mukti Rana and Donald Butler University of Texas at Arlington Electrical Engineering Dept. Arlington, TX 76019 Based in part by work supported by the National Science Foundation ECS-0322900.

gore
Download Presentation

Noise Reduction Of Si x Ge 1-x and Si x Ge 1-x O y Bolometers by Forming Gas Passivation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Noise Reduction Of SixGe1-x and SixGe1-xOy Bolometers by Forming Gas Passivation Mukti Rana and Donald Butler University of Texas at Arlington Electrical Engineering Dept. Arlington, TX 76019 Based in part by work supported by the National Science Foundation ECS-0322900

  2. Bolometer • Bolometers are the optical sensors whose resistivity varies with temperature. When lights fall on the bolometer surface the sensing material of the bolometer absorbs heat and there by changes it’s resistance.

  3. Why Noise Reduction is important • Noise detoriates the Bolometer’s performance by reducing the detectivity, responsivity. • Amorphous films are characterized by higher noise.

  4. Bolometer Fabrication Ashing of PI2737 in Oxygen Plasma SiN Ni Contact NiCr Absorber SiGeO SiN NiCr Arm PI 2737 Sacrificial Layer Ni Pad Al Mirror SiN Insulation Layer p-Si Substrate

  5. Micormacined Bolometer : SEM Picture

  6. Experimental Details of Forming Gas Passivation • The Bolometer’s noise was measured in a shielded probe station with the help of SRC560 low noise preamplifier, HP 3562 dynamic signal analyzer and a computer. The noise spectra of same device was measured before and after the passivation to compare the noise. • An AXIC Jet First Rapid Thermal Anneal (RTA) was used for annealing the sample. The sample was kept inside the chamber at a forming gas flow of 500 SCCM for different intervals of time.

  7. Results: Noise Voltage Power Spectral Density (PSD) at 0.6uA Bias Current of SiGeO Bolometer Before and After Forming Gas Passivation