NOx. Reading: Chap 16. Thermal NOx vs Fuel NOx Strategies for Combustion Modifications Off stoichiometric combustion, flue gas recirculation, water injection, gas reburning, low NOx burner Flue Gas Treatment SCR, SNR, Absorption, Adsorption. Thermal NOx vs Fuel NOx.
E N D
NOx Reading: Chap 16 • Thermal NOx vs Fuel NOx • Strategies for Combustion Modifications • Off stoichiometric combustion, flue gas recirculation, water injection, gas reburning, low NOx burner • Flue Gas Treatment • SCR, SNR, Absorption, Adsorption Aerosol & Particulate Research Laboratory
Thermal NOx vs Fuel NOx • Thermal NOx: formed by reaction between N2 and O2 in the air; sensitive to temperature • Fast formation rate at high temperature • Fast cooling rate freezes formed NOx • Fuel NOx: formed from combustion of fuels containing organic nitrogen in the fuel; dependent on local combustion conditions and nitrogen content in the fuel • NOx Control: • combustion modification --> prevent formation • flue gas treatment --> treat formed NOx Can absorption, adsorption or incineration be used to control NOx? Aerosol & Particulate Research Lab
Strategies for Combustion Modification Temperature as a function of equivalent ratio? • Reduce peak temperatures of the flame zone • Reduce gas residence time in the flame zone Aerosol & Particulate Research Lab
Modification of Operating Conditions • Off-Stoichiometric Combustion/Staged combustion: combusting the fuel in two or more steps. Fuel rich then fuel lean. • Flue gas recirculation: reroute some of the flue gas back to the furnace; lower O2 and allow NOx to proceed the “frozen” reactions • Water injection: reduce flame temperature; energy penalty Why? http://en.wikipedia.org/wiki/Staged_combustion_cycle_(rocket) Aerosol & Particulate Research Lab
Gas reburning: injection of natural gas into the boiler above the main burner to create a fuel-rich reburn zone; hydrocarbon radicals react with NOx to reduce NOx to N2. http://www.lanl.gov/projects/cctc/factsheets/eerco/gasreburndemo.html Aerosol & Particulate Research Lab
Low-NOx burner: inhibit NOx formation by controlling the mixing of fuel and air; lean excess air and off-stoichiometric combustion Avoid Peak Temperature Aerosol & Particulate Research Lab
Flue Gas Treatment • Selective Catalytic Reduction (SCR) Temperature ~ 300 - 400 oC Why is it called “selective”? Also good for Hg emission control!!! But it creates SO3. • Selective Noncatalytic Reduction (SNR) Temperature ~ 800 - 1000 oC Above 1000 oC Aerosol & Particulate Research Lab
http://www.lanl.gov/projects/cctc/factsheets/scr/selcatreddemo.htmlhttp://www.lanl.gov/projects/cctc/factsheets/scr/selcatreddemo.html Should a SCR reactor be installed before or after particle control devices? Disadvantages of SCR and SNR? Can SCR be used for removing NOx from diesel trucks? Aerosol & Particulate Research Lab