1 / 21

Incinerability of Halon s and HCFC s Theoretical Calculations of DRE

Incinerability of Halon s and HCFC s Theoretical Calculations of DRE. Presenter: Dr. Charles W. Lamb CHARLES LAMB and Associates Coauthors: Dr. Barry Dellinger, Louisiana State University Mark Wagner and Robert Lanza, ICF International. This research conducted.

gurit
Download Presentation

Incinerability of Halon s and HCFC s Theoretical Calculations of DRE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Incinerability of Halons and HCFCsTheoretical Calculations of DRE Presenter: Dr. Charles W. Lamb CHARLES LAMB and Associates Coauthors: Dr. Barry Dellinger, Louisiana State University Mark Wagner and Robert Lanza, ICF International

  2. This research conducted • At request of the U.S. EPA to determine thermal stability of five non-hazardous ODS (ozone depleting compounds) that have not been adequately tested in a U.S. destruction facility.

  3. Ozone Depleting Substances (ODS) • The earth’s stratospheric ozone layer is a protective barrier that prevents excessive amounts of harmful ultraviolet radiation (UVR) from reaching the earth’s surface. • ODS are chemicals that destroy ozone in the stratosphere

  4. Montreal Protocol • Signed by 180 countries (including the U.S.) • Sets a phaseout schedule for the production and consumption of ODS beginning with bromofluorocarbons (halons) and chlorofluorocarbons (CFCs), and later methyl bromide and hydrochlorofluorocarbons (HCFCs). • Recommends only technologies for halon destruction based on actual trials of ODS destruction units using halons • Units undergo expensive testing using halons and ODS as POHCs in their performance tests to physically measure the DREs achieved

  5. U.S. Clean Air Act (CAA) • Amended in 1990 to include Title VI, Stratospheric Ozone Protection • Federal regulations on the production, use, reclamation, and destruction of • class I ODS (e.g., CFCs), and • class II ODS (e.g., HCFCs, halons), and their substitutes.

  6. U.S. Clean Air Act (CAA) • Production of ODS is being ended according to a step-down schedule • There are no current federal, state, or local regulations in place that require • The removal of ODS from equipment • The destruction of any removed ODS • Some stockpiled ODS could be made available for destruction, particularly if incentives were provided

  7. ODS Destruction in HWCs • Montreal Protocol • Specifies the processes which should be used for ODS destruction, including incinerators and cement kilns • Requires 98% DRE • All known ODS destruction in the U.S. has occurred at RCRA-permitted HWCs.

  8. Project Summary • Certain ODS are not on U.S. EPA’s thermal stability ranking system • Need to determine the thermal stability of ODS such as halon 1301 and HCFC-22 that have not been tested in a U.S. destruction facility. • Need to determine whether these compounds can be safely destroyed in an existing U.S. hazardous waste combustor (HWC).

  9. Outline • Theoretical incinerability & DRE • Pseudo-first-order kinetics • Arrhenius parameters and equations • Halons (bromofluorocarbons) • HCFCs (hydrochlorofluorocarbons) • Rank in Incinerability Index • Potential PICs from incineration • By-products with ozone-depleting potential and/or global warming potential may form

  10. Incinerability Index Ranked 1 - 320

  11. DRE from Arrhenius Equation DRE = 100 (1-f) = 100 [1 – exp( -At exp(-E/RT))] where: DRE= destruction and removal efficiency, % f = fraction remaining undestroyed t = mean gas reaction time, s A = Arrhenius frequency factor, 1/s E= oxidation activation energy, kcal/mol T = absolute temperature, ºK

  12. Calculate Time or Temperature Calculate the time required to achieve the given DRE at temperature T. t = - (ln f/A) exp(503 E/T) Calculate temperature, T T = 503 E(ln(-tA/ln f))-1

  13. Arrhenius ParametersDerived from Theory and Database

  14. Incinerability Rankings EstimatedRelative T to get 99% DRE in 2 secs

  15. Temperatures for 99.99% DRE

  16. DRE OK but what about PICs? • ODS can be effectively incinerated to 99.99% DRE in a properly designed and operated HWC. • However, questions remain: • What products of incomplete combustion (PICs) may be formed and at what levels? • What will their ozone-depleting potential (ODP) and global warming potential (GWP) be?

  17. PIC? • For example, halon 1211 (CF2BrCl) would be expected to lose bromine and form a chlorofluorocarbon radical that could form an ODS compound that might survive the incineration

  18. Thermal Stability • Stability due to carbon-halogen bond strengths: • Fluorine - high • Chlorine - intermediate • Bromine - low • The destruction pathway of halons and CFCs always involves the bromine or chlorine atoms but not the fluorine atoms.

  19. PIC Formation • For example, incineration of HCFC-123 (CF3CHCl2) could form perfluroethane (CF3CF3) which is essentially un-incinerable • Possible production of thermally-stable PICs that have ozone-depleting or global-warming potential is a question that requires additional research

  20. Conclusions • Study proves that these ODS can safely be incinerated in any existing HWC facility which has a proven DRE of 99.99% for at least one class I POHC. • This makes expensive performance testing of halons and HCFCs in a HWC unnecessary. • Possible production of PICs that have ozone-depleting or global-warming potential is an issue that needs to be further investigated; this will require additional theoretical and possible experimental evaluation

  21. Thank you Charles W. Lamb, Ph.D. Phone (870) 862-2541 cwlamb@suddenlink.net