1 / 11

Ambient and Source Technology Integration

Ambient and Source Technology Integration. Dennis K. Mikel EPA-OAQPS-AQAD. Concept. Why initiate technology integration? Limited Funds Limited Manpower Time and effort. Task #1 Team Building. We formed an internal team Ambient Air Monitoring Group Measurement Technology Group

gus
Download Presentation

Ambient and Source Technology Integration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ambient and SourceTechnologyIntegration Dennis K. Mikel EPA-OAQPS-AQAD

  2. Concept • Why initiate technology integration? • Limited Funds • Limited Manpower • Time and effort

  3. Task #1 Team Building • We formed an internal team • Ambient Air Monitoring Group • Measurement Technology Group • We looked at different technologies • Chose one we felt we could have success

  4. Task #2 Initiate technology integration project • We contacted: • Cooper Environmental – X-Ray Fluorescence (XRF) Experts • Met One Instruments – Beta Attenuation Monitors (BAM) Technology • California Air Resources Board - Operate Met One BAMs • We created a partnership!

  5. Technology Integration Cooper XRF Technology Met One EBAM Met One Mylar backed Tape – Teflon Coated

  6. Bakersfield Time Series Plot 3,500 PM X 10^-4 As X 2 3,000 Cr Pb 2,500 Mn Ni 2,000 Conc. (pg/dscm) 1,500 1,000 500 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Sample Number Results of Collaboration

  7. Long Term Plan • Development of the semi-continuous multi-metals for fence-line and ambient applications • Lowering Detection Levels for formaldehyde and 1,3 BD using Cascade Lasers – ORD development • Pneumatic Focusing Gas Chromatography

  8. Multi-metals Fence-line – Ambient Applications • The Xact Ambient Air Toxics Monitor (Xact AATM) measures the ambient concentration of metals • Based on uses X-ray fluorescence • Sampling times for this instrument range from one to four hours. • The Xact AATM measures metals in the pg/m³ concentration range.

  9. MID-IR Cascade Laser System • Uses Tunable Infrared Laser Differential Absorption • Continuous automated operation • Detection Limit (pptv) • Formaldehyde 60 Butadiene 80 • Acrolein 120

  10. Pneumatic Focusing Gas Chromatography (PFGC) • Air sample compressed • and injected directly on column in a specially designed GC • GC is constructed within a fully functional personal computer • FID-VOC sensitivity of 50 ppt

  11. Technology IntegrationToolbox Research SBIR Collaborate with Vendors and S/L/T ORD An Intelligent Approach to Technology Integration!!!