1 / 20

Field Audit & System Blank FAQs

Field Audit & System Blank FAQs. NADP Webinar Series August 21, 2013. Frequently Asked Questions. May I process the Field Audit or System Blank sample? I know that it did not rain or snow during the sampling period, but. 1) the collector opened at least once during that time.

Download Presentation

Field Audit & System Blank FAQs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Field Audit & System BlankFAQs NADP Webinar Series August 21, 2013

  2. Frequently Asked Questions

  3. May I process the Field Audit or System Blank sample? I know that it did not rain or snow during the sampling period, but...

  4. 1) the collector opened at least once during that time. YES. Provided no precipitation occurred during the sampling period, collector openings are acceptable. 2) dew or moisture condensing on the sensor caused the collector to open. NO, generally. The sensors (grid and optical) are heated. Moisture should not form on the sensor. Verify that the sensor is working properly. If yes, the sensor may have been triggered by mist or light rain/snow.

  5. 3) fog caused the collector to open. NO, generally. Fog can result from either a low lying cloud, or from moisture evaporating from the Earth’s surface. Explain lid openings on MOF or FORF. 4) there is insect and/or plant material in the bucket, funnel, or bottle. YES. This is the goal of the Field Audit and System Blank programs. 5) the collector lost power (while closed) and did not operate for a portion of the sampling period. No.

  6. 6) there was light precipitation during the sampling period, but the collector did not open. NO. For consistency within the Field Audit and System Blank programs, the sampling period must be dry. 7) the Field Audit or System Blank sample has an expiration date that has passed. YES. Provided the sample is for the current year, it may still be used. If the sample is from a previous year, dispose of the sample, and submit the accompanying postcard.

  7. 8) the Field Audit or System Blank sample has an expiration date from a previous year. NO. Dispose of the sample, and submit the accompanying postcard. 9) the Field Audit or System Blank sample bottle broke or leaked during shipment to my site. NO. Dispose of any remaining sample, and submit the accompanying postcard – if it is in good condition. If the postcard is damaged, notify Greg Wetherbee at wetherbe@usgs.gov. Note, the Field Audit and System Blank samples are not hazardous.

  8. 10) I poured the entire sample into the NTN bucket (or MDN bottle), what should I do? Dispose of the sample, and submit the accompanying postcard. Note, the Field Audit and System Blank samples are not hazardous. 11) I poured the proper amount into the NTN bucket (or MDN bottle), but then discarded the remaining portion. What should I do? Dispose of the sample, and submit the accompanying postcard with a note explaining what happened. Note, the Field Audit and System Blank samples are not hazardous.

  9. I (accidentally?) poured the entire Field Audit/System Blank sample into a valid NTN (or MDN) sample. What should I do? Dispose of the sample, and contact the Site Liaison and Greg Wetherbee (wetherbe@usgs.gov). Note, the Field Audit and System Blank samples are not hazardous.

  10. Common Mistakes • DO NOT send a dry sample envelope (NTN) when submitting a Field Audit sample. The 2 bottles for the Field-Audit sample and 2 accompanying FORFs are all that is needed. • Two (2) bottles should be submitted for all Field-Audit and System-Blank samples: (1) the sample that rinsed the bucket (NTN) or sample train (MDN), and (2) the portion of sample still remaining in the original bottle shipped to you by USGS.

  11. Results “So, what does USGS do with these data anyway?”

  12. Results

  13. Online Training Videos http://pubs.er.usgs.gov/publication/ofr20061010

  14. Online Training Videos http://bqs.usgs.gov/PCQA/System_Blank/systemBlankTrainingVideo.php

  15. A recording of this webinar will be made available on the NADP website: http://nadp.isws.illinois.edu

  16. Contacts • Greg Wetherbee, USGS Precipitation Chemistry Quality Assurance Project Chief, 303-236-1837, wetherbe@usgs.gov • RoseAnn Martin, USGS Precipitation Chemistry Quality Assurance Project, Physical Scientist, 303-236-1874, ramartin@usgs.gov • Web site: http://bqs.usgs.gov/

  17. Special Thanks • RoseAnn Martin (USGS) – Field Audit and System Blank implementation, webinar props • Mark Rhodes (NADP Program Office) • Brian Kerschner, Jeff Pribble (Central Analytical Laboratory) • Jason Karlstrom (Frontier Global Sciences, HAL)

  18. Additional Credits • Catch Efficiency Technician: Phil DeBuckets • Optical Sensor Engineer: Dewey C. Rain • Contamination Technician: Harry Messinwater • Quality Assurance Assistant: Howie Duin • Belfort Chart Reader: Violet Fingers • Meteorologist: Gail Forcewinds • Customer Service Rep.: Ida Noh • SOP Editor: Reed Pages • Accountant: Bill U. Later • Webmaster: Dorothy “Dot” Kahm

More Related