E N D
1. The Ultimate Pressure Control Digihelic®
2. Digihelic® Who Has Not Sold a Digihelic????????
IF YOU HAVE NOT YET, YOU ARE MISSING EASY SALES OPPORTUNITIES
3. Digihelic® Capabilities Selectable Engineering Units
Pressure:
4. Digihelic® Capabilities Selectable Engineering Units
Air Velocity:
FPM, M/S
Air Flow:
SCFM, M3/HR
5. Digihelic® Capabilities Display % of Full Scale Instead of Eng. Units
Records Peak & Valley Readings
4 Levels of Security
Truly Universal Power Supply
120 VAC; 240 VAC; & 24 VDC
4-20 mA Standard on ALL Models
K-Factor Selection for Various Flow Sensors
Digital Dampening of Display & Output
6. Digihelic® Capabilities Full Scale Accuracy of 0.5% on Ranges:
0-0.25 & .25-0-.25" w.c. (60 Pa; ±60 Pa)
0-1 & 1-0-1" w.c. (250 Pa; ±250 Pa)
2.5-0-2.5" w.c. (±620 Pa)
0-5 & 5-0-5" w.c. (1.25 kPa; ±1.25 kPa)
0-10 & ±10" w.c. (2.5 kPa; ±2.5 kPa)
0-25" w.c. (6.23 kPa)
0-50" w.c. (12.45 kPa)
0-100" w.c. (25 kPa)
7. Digihelic® Capabilities Quick Field Calibration Via Menu Buttons
4 & 20 mA Process Rescaling
Hot Key for Quick Access to Set Point/Alarm Viewing or Adjustment
Modbus Communications Standard
2 SPDT 8 Amp Relays
8. Digihelic® Capabilities 3 Modes of Operation
Single Set Point with Adjustable Dead Band
Dual Set Points with Adjustable Dead Bands
Single Set Point with Separate Alarm Output
9. Digihelic® Capabilities Mode with Single Set Point & Separate Alarm Manual Reset can also be achieved remotely. You can wire to the unit a reset button. Manual Reset can also be achieved remotely. You can wire to the unit a reset button.
10. Digihelic®: Competition? ? æ ?
Meriam
Modus
Precision Sensors
(Division of United Electric)
11. Digihelic® VS. Meriam 2100 Meriam 2100
Lowest Range of 20" w.c.! (5 kPa)
1 Model for Pressure; 2nd Model for Flow
1 Model for 120 VAC
Available Only with Switches
2nd Model for 24 VDC
Available Only with 4-20 mA Output
Priced @ $795
12. Digihelic® VS. Modus DA Modus DA
Inaccurate with 1% full span + 1 Digit
No engineering units conversion
Transmitter Standard. But Switches Optional, and Another Option for a Square Root Output
3 Separate Models for 120/240 VAC, 24 VDC
Price with Alarms: $420
Price with Square Root Output: $475
13. Digihelic® VS. U.E. Echoline U.E. Echoline
1% Full Scale Accuracy
Optional Engineering Units Conversion
No Square Root Output for Air Flow
Optional 4-20 mA Output
12-24 VDC Power Only
OEM Pricing of $295 Net Regardless of Qty.
14. Digihelic® VS. Modus Titan Modus Titan
Lowest Range of ±2" w.c.
2 Metric Ranges in Pa Optional
Optional LED Display of Set Point Activation
Relay Outputs Optional
Process Signal Output Optional
Price $330: 2 Amp Relays & Process Output
15. Digihelic® Endless Potential Customer Using a D.P. Gage & Separate D.P. Transmitter?
ORDER A DIGIHELIC®
16. Digihelic® Endless Potential Need a Differential Pressure Switch & Set Point Indication on a Control Panel?
ORDER A DIGIHELIC®
17. Digihelic® Endless Potential Need a Photohelic and Separate High Alarm?
ORDER A DIGIHELIC®
18. Digihelic® Endless Potential Need a D.P. Gage/Transmitter with a Scale in mm w.c., mm Hg, kPa, Ft. w.c., hPa, cm w.c. or mBar?
ORDER A DIGIHELIC®
19. Digihelic® Endless Potential Need a D.P. Gage with Special SCFM or M3/Hr Air Flow Scale?
ORDER A DIGIHELIC®
20. Digihelic® Endless Potential Need a Differential Pressure Transmitter with Modbus Communications Output?
ORDER A DIGIHELIC®
21. Digihelic® Endless Potential Need a Differential Pressure Transmitter with Data Logging Capabilities?
ORDER A DIGIHELIC®
22. Digihelic® Endless Potential Do You Have Customers Who:
Observe Pressure in Clean Rooms?
Monitor Gas Cabinet Exhaust Systems?
Control Dust Collection Cleaning Systems?
Control Dampers on Industrial Ovens?
Control Air Handlers Fan Output?
Monitor Proper Fume Hood Flow?
Ensure Proper Glove Box Pressurization?
23. Still Not Convinced? Ask Our Customers:
Temtrol
Manufacturer of Air Handling Units
Germfree Laboratories
Leaders in Bio-Safety Cabinets
The Baker Company
Bio Cabinets and Fume Hoods
Sez Inc.
Wafer Processing Environmental Chambers
24. U.S. Fortune 500 Customers Tyson Foods: Food Processing
Eastman Kodak: Photographic Paper
Bayer Corporation: Drug Manufacturer
Honeywell, Trane & Johnson Controls: Building Automation Systems
General Electric: Global Research Center
MIT Research Labs purchased units. Gemini Observatory telescope in Hilo Hawaii for their laser and clean rooms. MIT Research Labs purchased units. Gemini Observatory telescope in Hilo Hawaii for their laser and clean rooms.
25. Unique Application PSEG (Public Service Electric & Gas)
Coal Burning Power Plant in New Jersey
Trying to Control NOx Emissions
Selective Catalytic Reduction (SCR) Process Reduces NOx 50-60%
SCR Injects Ammonia into the Exhaust
Utilize an Averaging Pitot Array and 0-5" w.c. Digihelic® to Monitor the Air Flow in SCFM
Monitor the Flow System Wirelessly and Can Adjust as Needed Ammonia injection done with various valves. Ammonia injection done with various valves.
26. Digihelic Links Communications Program for the Digihelic®
27. Digihelic Links Communications Program
Enables Customer to Set or Change Any Parameter in the Digihelic from a Computer
An Entire Plant of Digihelics Can be Monitored/Controlled from A Single Location
User Can: Review an Event Log, Graph Data, Calibrate Zero & Span
28. The Ultimate Pressure Control In Summary the Digihelic® :
Has the Capacity to Be Selected for Almost any Pressure or Air Flow Application
Provides Core Dwyer Customers the Ability to Have the Highest Possible Control of Their Application in One Product