Part 6 Synthesis of Heat Exchanger Networks
6.1 Sequential Synthesis Minimum Utility Cost
Example 1 Steam: 500 C Cooling water: 20 – 30 C Minimum recovery approach temperature (HRAT): 20 C
Remarks • LP for minimum utility consumption leads to the same results as the Problem Table in Pinch method. • The transshipment model can be generalized to consider multiple utilities to minimize total utility cost. • This model can be expanded so as to handle constraints on matches. • This model can also be expanded so as to predict the matches for minimizing the number of units. • We can embed the equations of the transshipment model within an optimization model for synthesizing a process system where the flows of the process streams are unknown.
Example 2 HP Steam: 500 K, $80/kW-yr LP Steam: 380 K, $50/kW-yr Cooling Water: 300 K, $20/kW-yr HRAT: 10K
Sequential Synthesis Minimum Utility Cost with Constrained Matches
Heat Exchange Options • Hot stream i and cold stream j are present in interval k (see figure in the previous page). • Cold stream j is present in interval k, but hot stream i is only present at higher temperature interval (see figure in the next page).
Example 1 Steam: 500 C, $80/kW-yr Cooling water: 20 – 30 C, $20/kW-yr Minimum recovery approach temperature (HRAT): 20 C The match between H1 and C1 is forbidden.
Condensed Transshipment Model The annual utility cost: $9,300,000.
Expanded Transshipment Model Annual Utility Cost: $15,300,000 Heating Utility Load: 120 MW Cooling Utility Load: 285 MW
Sequential Synthesis Prediction of matches for minimizing the unit number
Heat Balances The constraints in the expanded transshipment model can be modified for the present model: • The heat contents of the utility streams are given. • The common index i can be used for hot process and utility streams; The common index j can be used for cold process and utility streams.
Example 1 Steam: 500 C Cooling water: 20 – 30 C Minimum recovery approach temperature (HRAT): 20 C
Sequential Synthesis Automatic Generation of Network Structures
Basic Ideas • Each exchanger in the superstructure corresponds to a match predicted by the MILP model (with or without pinch partition). Each exchanger will also have as heat load the one predicted by MILP. • The superstructure will contain those stream interconnections among the units that can potentially define all configurations. The stream interconnections will be treated as unknowns that must be determined.
Embedded Alternative Configurations • H1-C1 and H1-C2 in series • H1-C2 and H1-C1 in series • H1-C1 and H1-C2 in parallel • H1-C1 and H1-C2 in parallel with bypass to H1-C2 • H1-C1 and H1-C2 in parallel with bypass to H1-C1