Sub<23 nm Particles Key Messages

Transmitted by the PMP Chair. Informal document GRPE-68-21 ( 68 th GRPE, 7-10 January 2014, agenda item 7 ). Sub<23 nm Particles Key Messages. Document discussed in the PMP meeting 08 Jan 2014. Overview. Particles < 23nm are partially measured today

hafwen
Download Presentation

Sub<23 nm Particles Key Messages

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transmitted by the PMP Chair Informal document GRPE-68-21 (68thGRPE, 7-10 January 2014, agenda item 7) Sub<23 nm Particles Key Messages Document discussed in the PMP meeting 08 Jan 2014 PMP-29-02

  2. Overview • Particles < 23nm are partially measured today • The system today works well and is applied across the industry • Light duty • Heavy duty • Extension to NRMM underway PMP-29-02

  3. Particle size / composition • Existing technologies (eg GDI) do not have significantly smaller particle size range than diesels with DPF • Some particles < 23nm on GDI sometimes identified but only at certain specific conditions. The percentage not measured is typically <60% (on average 30-40%) and comparable to diesels (<20%) • We do not know what these particles are – physically or chemically – more work required PMP-29-02

  4. Measurement Equipment - PNC • PNC could be adapted to measure particle size down to 10nm • Current PNC could NOT be adjusted to measure below 10nm. Different model is necessary. It is not as simple as plug and play. PMP-29-02

  5. Measurement Equipment - VPR • VPR Evaluated as not robust to measure down to either 10 or 3 nm today (volatile artifacts are common) • Alternative could be catalytic stripper • Catalytic stripper has also some issues to overcome • Calibration of VPR and determination of transfer functions / losses will be a further issue • Uncertainty of measurement expected to increase when solid sub-23nm particles exist. PMP-29-02

  6. Calibration • ENV-02 recommended ‘not a soot like aerosol’ for calibration – but has not suggested what should be done instead. • Calibration significant challenges for reference CPC (would need to be calibrated to lower particle size). Potentially all calibration to be done by electrometer – fundamental PMP-29-02

  7. Recommendations / Next Steps • No urgent need identified to revise measurement to < 23nm today. • New / emerging technologies to be kept under review regarding <23nm particles. • EU Com requested PMP to continue to develop a robust < 23nm method in case of future need. • PMP will develop a plan and timeline • Guidelines to avoid artefacts to be developed when measuring <23nm particles • With the above recommendations, the work on regeneration measurements for LD vehicles can start. PMP-29-02