3508/3504

3508/3504. What is the 3500 Range?. Not a 2400 replacement! 818/902 performance controller/programmer 2408/2404 compatible terminals assignment 2400 simplicity with 2604 flexibility Flexible configuration tools for creative solutions. Where should we sell it?. Aerospace & Defence

Download Presentation

3508/3504

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3508/3504

  2. What is the 3500 Range? • Not a 2400 replacement! • 818/902 performance controller/programmer • 2408/2404 compatible terminals assignment • 2400 simplicity with 2604 flexibility • Flexible configuration tools for creative solutions

  3. Where should we sell it? • Aerospace & Defence • Heat Treatment, composite curing, environmental test • Semiconductor • Crystal growing, MBE, CVD, environmental test • Automotive • Heat treatment, paint drying, environmental test • Bricks & Ceramics • Drying, firing, glazing • Glass • , Forehearth heating, annealing lears • Pharmaceutical • Fermentation, culture growth, freeze dryers, reactors • Process Applications • Flow dosing

  4. 3508 - 96x 48mm 3500 Range Summary • Precision 1uV main PV input • Single PID loop • 50 programs, 200 segments • Maths, logic & timer functions • 3508 supports up to 3 I/O modules • 3504 supports up to 6 I/O module 3504 - 96x 96mm

  5. 3500 Range Summary • Graphical configuration tools • Front panel IR communication interface • Built in- logic I/O & relay • 24Vdc transmitter PSU • Uses digital I/O Expander

  6. 3508 Display Concept Output/ Status Beacons Alarm Beacon PV Units 41/2 Digit PV Display 10 x 4 Character, Graphic/ Text display Large SP Display • Programmer Home • Screen • Setpoint • Time Remaining • Program Number • Segment Number Infrared Communication Port

  7. 3504 Display Concept Output/ Status Beacons Alarm Beacon Display Units 51 point Bar Graphwith alarm indication 20 x 4 Character, Graphic/ Text display 5 digit PV Large SP Display • Programmer Home • Screen • Setpoint • Time Remaining • Program Number • Segment Number Infrared Communication Port

  8. 3500 Terminations Logic out - 24V/15mA logic input 24Vdc transmitter supply Note: RTD terminals as 26/27

  9. 3508/04 Modular I/O • Output modules • Change over relay • 2 Pin relay • Dual relay • Single triac • Dual triac • Analog DC control • Analog DC retransmission • Isolated single logic • Triple logic • Input modules • Analog input(26/27(AM) module) • Not Slots 2 or 5 • Triple logic input • Triple contact input • Potentiometer input • Power supply modules • 24Vdc transmitter supply • 5/10Vdc transducer supply • Communication modules • 232 Modbus RTU • 2 wire 485 Modbus RTU • 4 wire 485 Modbus RTU • IO Expander

  10. Control Options • Single PID loop • PID, ON/OFF • VP Heat/VP Cool • PID Heat/VP Cool etc • Advanced control features • Flexible wiring of function blocks • Similar functionality to single loop 2604 • Configured using iTools Graphical Editor

  11. Setpoint Programmer • 50 Programs, 200 Segments • Various ordering options • Single SP profile • 8 Digital event outputs • Segment types • Rate, Dwell, Step, Target, Call, End • Digital inputs

  12. Toolkit Functions • Maths functions • 2 input x 24 • 8 input switch x 4 • User value x 16 • Logic functions • 2 input x 24 • 8 input x 2 • Timer functions • Real time clock • Timer x 4 • Counter x 2 • Totaliser x 2 • Other functions include • Transducer Scaling x 2 • Custom Linearisation x 2 • Switchover • Load simulation

  13. User Pages • 8 Pages • 64 Parameters • Various display formats

  14. Recipes • 8 Sets, each set can a given meaningful name • 24 Tags(parameters) per set • Typical example of Tags; Control SPs, Alarm SPs, PID values etc • Sets can be selected by HMI or communications

  15. Communications • Modbus RTU slave • Master Modbus RTU • Broadcast of single parameter • More options coming soon SCADA/DCS Modbus RTU

  16. Infra Red Clip • In-Situ Communications • No loss of sealing • Commissioning • Cloning • Diagnostics

  17. Order Code - Hardware & Functions 20

  18. Order Code - IO Modules

  19. Quick Start HMI • Quick Start HMI provides an intuitive series of questions to allow a user to configure a simple 3500 application without itools • Enables all blocks in 3500 and makes wires

  20. Future Development • Phase 1A - April 04 • More communication options • Profibus DP, DeviceNet, EI-Bisync • Supports IO Expander • Zirconia block • Quick start HMI • Phase 2 – Late Summer 04 • 2 PID loops • 2 Setpoint profiles • Programmer PV events • Ethernet Modbus TCP/IP • What we are doing next • Cascade, override, ratio • Master Modbus

  21. Why Buy 3500? • Flexible and competitive controller • Single loop 2604 at lower cost • Easy and fast configuration • Saves time, money and easier to be right first time • 0.1% Measurement accuracy • High performance control at 2400 costs • Wide selection of IO modules • Reduces spares holding • Caters for more applications • Configurable and intuitive display • Provides clear view of current process state • Recipes simplify process changes • Available in languages other than English