1 / 37

miniHAWC

g. miniHAWC. mini- H igh A ltitude W ater C herenkov experiment. Jordan Goodman University of Maryland. Lexicon. Milagro – Existing water Cherenkov wide-field all-sky gamma-ray observatory near Los Alamos, NM.

hamlet
Download Presentation

miniHAWC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. g miniHAWC mini- High Altitude Water Cherenkov experiment Jordan Goodman University of Maryland Jordan Goodman Beijing – June 2006

  2. Lexicon • Milagro – Existing water Cherenkov wide-field all-sky gamma-ray observatory near Los Alamos, NM. • HAWC – A ambitious effort to construct an wide-field all-sky observatory with point source sensitivity of the Whipple 10m. • miniHAWC – Demonstrate HAWC technology at low cost with Milagro PMTs and instrumentation, with potentially large scientific payoff. Jordan Goodman Beijing – June 2006

  3. Detector Layout HAWC: 5625 or 11250 PMTs (75x75x(1 or 2)) Single layer at 4m depth or 2 layers at Milagro depths Instrumented Area: 90,000m2 PMT spacing: 4.0m Shallow Area: 90,000m2 Deep Area: 90,000m2 miniHAWC: 841 PMTs (29x29) 5.0m spacing Single layer with 4m depth Instrumented Area: 22,500m2 PMT spacing: 5.0m Shallow Area: 22,500m2 Deep Area: 22,500m2 Milagro: 450 PMT (25x18) shallow (1.4m) layer 273 PMT (19x13) deep (5.5m) layer 175 PMT outriggers Instrumented Area: ~40,000m2 PMT spacing: 2.8m Shallow Area: 3500m2 Deep Area: 2200m2 Jordan Goodman Beijing – June 2006

  4. Altitude 4300m 2600m Difference between 2600m (Milagro) and 4300m (Tibet): ~ 6x number of particles ~ 2x lower energy threshold Jordan Goodman Beijing – June 2006

  5. Detector Layout Milagro 1.5 m Milagro: 2 layers at depths 1.5m – “Air Shower” Layer 5.5m – “Muon” Layer 5.5 m 2.8 m miniHAWC: Single intermediate layer opaque curtains between cells miniHAWC 5 m 4m Jordan Goodman Beijing – June 2006

  6. Curtains • A high altitude version of Milagro would trigger at >10kHz. Need to control spurious triggers due to single muons. • Install curtains to optically isolate the PMTs. • Intrinsic Gamma hadron separation Jordan Goodman Beijing – June 2006

  7. Milagro Instrumentation • 899 8” Hamamatsu PMTs • Bases, encapsulation • Single rg59 cable for data and HV. • Custom front end boards • Signal shaping and threshold detection • Trigger primitive generation • Pulse height through TOT method. • FastBus TDC’s • Capable of ~2000Hz or 6MB/s readout • VME-FastBus interface for readout Jordan Goodman Beijing – June 2006

  8. Gamma/Hadron Separation Lateral distribution of EM energy and muons. Jordan Goodman Beijing – June 2006

  9. Simulation Strategy • Use Milagro Simulation/Reconstruction software (without weighting). • Use observed Milagro crab signal to anchor simulations to reality.  Shared systematics with Milagro. • Use new g/hadron discrimination variable for HAWC/miniHAWC that excludes the core location. CMilagro = (nPMTs > 2 PE)/(Max “muon layer” hit) CminiHAWC =(nPMTs > 2 PE)/(Max “muon layer” hit >20m from core) Jordan Goodman Beijing – June 2006

  10. Triggering with Curtains • Multiplicity trigger at ~70 PMTs gives same • trigger rate as Milagro at 50 PMTs • Much higher Gamma area. protons gammas Jordan Goodman Beijing – June 2006

  11. Q (sig/√bg) ( miniHAWC/Milagro) = 15 Single layer doesn't limit sensitivity miniHAWC Sensitivity Significance from Crab Transit (~5 hr) 4s Crab signif/year 80s 5s point source sensitivity reach ~60mCrab of 1 year survey Energy Resolution ~30% above median Angular Resolution 0.25O-0.40O Energy (Crab Spectrum, nTop/cxPE>5.0., q<30O) nTrig>50 Ethr~700 GeV nTrig>200 Ethr~2TeV S/B (hard cuts) ~ 1:1 for Crab Typical day 20 excess on 25 bkg Jordan Goodman Beijing – June 2006

  12. Angular Resolution s = ~0.4o s = ~0.25o n Trigger = 50 n Trigger = 200 Jordan Goodman Beijing – June 2006

  13. / hadron Separation Q Factor (sig/√bg) Cuts soft hard miniHawc 2 4.5 Hess 3.2 4.4 Hess eg = 56% -> 28% eCR=3% -> 0.4% (shape only) Cut: nTop/cxPE>5.0 Eff g = 34% Eff CR= 3% Cut: nTop/cxPE>5.0 Eff g = 56% Eff CR= 1.5% Jordan Goodman Beijing – June 2006

  14. 30 GeV 70 GeV 230 GeV Gammas 270 GeV 20 GeV 70 GeV Protons Gamma/Hadron Separation Size of miniHAWC Size of Milagro deep layer Jordan Goodman Beijing – June 2006

  15. Effective Area Gamma Area: q<30o nTop/cxPE>5.0 Dq<1.0O 200 PMT Trigger 80 PMT Trigger 20 PMT Trigger Pond Area Jordan Goodman Beijing – June 2006

  16. Comparison of Effective Areas 50 Tube Trigger Jordan Goodman Beijing – June 2006

  17. Sensitivity Increase from Milagro to MiniHawc • 15x Sensitivity increase over Milagro ~3x from Altitude, Area ~3x from g/hadron separation ~1.5x from Angular resolution • ~60mCrab sensitivity (5s in 1year) Jordan Goodman Beijing – June 2006

  18. GRB Sensitivity Milagro miniHAWC Fluence Sensitivity to 100s GRB. Both Milagro and miniHAWC can “self trigger” and generate alerts in real time. GRB rate in FOV ~100 GRB/year (BATSE rate) Jordan Goodman Beijing – June 2006

  19. The Diffuse Galactic Plane in miniHAWC and HAWC Use Neutral H map to trace out VHE Gamma-Ray flux. Normalize to Milagro observed TeV diffuse emission from the Galactic plane. Jordan Goodman Beijing – June 2006

  20. Pond Design • Fiducial volume: 150m x 150m x 4m • Actual size: 170m x 170m x 5m • 1:1 slope at perimeter • Min 4½m depth to allow for 4m over PMTs. • Total volume: 115 Ml 170m 6m 4.5-5.0 m 150m Jordan Goodman Beijing – June 2006

  21. Building Construction • Prefabricated steel building • Components manufactured at factory. • Shipped to site (~9 trucks) • Beams bolted not welded. • Cost ~1M$ (not installed) • Building installation ~400 k$ • Pond excavation ~300 k$ • Liner cost ~600 k$ Total facility cost ~2.5-3.0M$ 170m 170m Jordan Goodman Beijing – June 2006

  22. Sierra Negra, Mexico ~1 ½ hr drive from Puebla ~4hr drive from Mexico City Saddle between Sierra Negra (z=4500m) and Orizaba (z=5600m) Site under development as a multiuse scientific facility. Jordan Goodman Beijing – June 2006

  23. Sierra Negra, Mexico Elevation = 4030m Latitude = 19O 00’N Longitude = 97O 17’ W Jordan Goodman Beijing – June 2006

  24. La Paz, Bolivia • Population: 1 Million • Elevation: 3900-2900 meters • Airport in El Alto • < 30 min from downtown • Elevation 4100 m • El Alto pop. 0.5 Million Jordan Goodman Beijing – June 2006

  25. El Alto viewed from Mt. Chacaltaya Jordan Goodman Beijing – June 2006

  26. Potential Sites Mt. Chacaltaya Cosmic Ray Laboratory 4806 meters +- 13 meters • South 16 deg 22.381’ • West 68 deg 08.758’ 4443 meters +- 10 meter • South 16 deg 24.837’ • West 68 deg 08.979’ Grid on Map is 1 km x 1km Water is plentiful, maybe too much so. Latitude: 16O 30’ S Longitude: 68O 11’ W La Paz El Alto Jordan Goodman Beijing – June 2006

  27. YBJ Laboratory – Tibet, China Elevation: 4300m Latitude: 30O 13’ N Longitude: 90O 28’ E Lots of space. Available power. Available water. Tibet Air Shower Array Jordan Goodman Beijing – June 2006

  28. YBJ Laboratory – Tibet, China Also home of ARGO observatory. ARGO utilizes RPC’s for EM particle detection. No Calorimetry. Jordan Goodman Beijing – June 2006

  29. Milagro:3.5 GV Sierra Negra: 7.7 GV Tibet- 13.1 GV La Paz: 12.0 GV Geomagnetic Cutoff Singles rates at sites under consideration are reduced by ~20-30% due to improved geomagnetic cutoff. Jordan Goodman Beijing – June 2006

  30. Triggering and DAQ • Milagro DAQ in its current form should be capable of triggering to multiplicities as low as ~80 PMTs. (~1800 Hz) • Simulation indicates that we can reconstruct gamma-ray events as small as ~20 PMTs. • Potentially huge sensitivity increase to GRBs if DAQ can be easily upgraded. Jordan Goodman Beijing – June 2006

  31. DAQ Upgrade • Move to VME TDC bases DAQ. • CAEN 1190 • Capable of >40MB/s • 10-20kHz Readout. • Cost ~100k$ Jordan Goodman Beijing – June 2006

  32. Costs • Facility ~$3M • Excavation, Liner, Building, Roads etc. • Water Recirculation System ~$50k • Cabling DAQ Upgrade ~$200k • Other costs: ~$600k? • Computing, Archiving, Monitoring, Cooling, Shipping… • Getting the Water (site dependent) • Electrical (site dependent) • Communications (site dependent) Jordan Goodman Beijing – June 2006

  33. Summary • 15x Sensitivity increase over Milagro • ~60mCrab sensitivity (5s in 1year) • Mostly proven technology • Leverage $1.5M investment in Milagro equipment • Could construct rapidly if site available. • Next Logical Step toward HAWC Jordan Goodman Beijing – June 2006

  34. DC2 Catalog (from J McEnery) Conclusion Jordan Goodman Beijing – June 2006

  35. HAWC: Simulated Sky Map • C&G AGN • Hartmann IR model • known TeV sources • Milagro extended sources • 1-year observation Jordan Goodman Beijing – June 2006

  36. 1500 hrs/fov 7 min/fov 4 min/fov 1500 hrs/fov Survey Sensitivity Jordan Goodman Beijing – June 2006

  37. EGRET Crab Nebula GLAST Current synoptic instruments Whipple VERITAS/HESS miniHAWC HAWC Detector Sensitivity (Single Location) Jordan Goodman Beijing – June 2006

More Related