CHEMISTRY 1105 Determination of Absolute Zerousing Vernier Equipment
Absolute Zero • CONNECTIONS: Thermometer, Ruler and Capillary Tube • CHEMISTRY 1105 Then insert capillary tube between the elastics. Align air column in tube at the base to ruler. Thermometer is attached to the ruler with 2 elastics that are wrapped twice.
Absolute Zero • CONNECTIONS: Setting up the Ring Stand and Water Bath. Build from the bottom upwards. • CHEMISTRY 1105
Absolute Zero • CONNECTIONS: Inserting Thermometer and Ruler in the Water Bath and clamping. • CHEMISTRY 1105 • Note that the top of the Capillary Tube is at • least 1 cm above the water line. • The Ruler and Thermometer is also about 1cm • above the Stir Bar to minimize interference.
Absolute Zero • CONNECTIONS & POWER: • CHEMISTRY 1105 Power Button Power Button Power Connection Power Connection
Absolute Zero • Fill the beaker with tap water to about 80% and add about 5 ice cubes. • Make sure that the stirrer does NOT touch the ruler and thermometer when it starts stirring. Turn on the Stirplate to give even stirring. • Read the bottom of the red oil droplet in the capillary tube. • CHEMISTRY 1105
Pressure vs. Volume • Tap on the Mode box to change the setting to Events with Entry. • Name the EventColumn Height and enter the units as mm. • CHEMISTRY 1105
Absolute Zero • Tap on the X/Y Table Icon to enter your data. Tap on ColumnHeight to adjust the recorded value to the correct number of significant figures. For ColumnHeight it should read to one decimal place (eg+0.5mm). Tap on Temperature to adjust the recorded value to 2 decimal places. • Tap on the GaugeIcon . • Once the temperature seems to be steady between 0 to 10oC and the ice cubes have melted, enter the accurately measured height (to +0.5mm) into the Column Height (mm) column. Now you can start the experiment by clicking on the Collect Button. • Tap on the Keep Icon . Enter the reading into the Column Height (mm) table. • Record the temperature and height every 6 to 10 degrees. Turn the hotplate on to 3 and once the temperature reaches 30oC increase the heat to 5. Stop when the temperature reaches 80oC. • CHEMISTRY 1105
Absolute Zero • You should have at least 12 different data points after completing the experiment. • Press the Stop Button to stop collecting data. • Tap on the X/Y Table Icon . Record the data shown in the Run table into your lab notebook. • Click on Graph Icon to view the data points on a grid. Make a rough sketch in your notebook of the graph. • CHEMISTRY 1105
Absolute Zero • Shut down the Lab Quest 2. • Turn the Power Off by pressing the Power button. • Graph your data using Excel. • Graph Column Height (mm) versus Temperature (oC). • Determine the slope and y-intercept of the line and using the equation • y=mx + b determine the value of absolute zero. • Create a graph in Excel. Go to http://kwantlen.ca/science/chemistry/chem1210/richsup/excel.pdf • CHEMISTRY 1105