1 / 27

휴대용 공기견인장비의 경추간반에 대한 견인효과의 MRI 연구 정태섭 1) , 강성웅 2) , 나영무 2) , 박준수 2) , 박창준 3)

휴대용 공기견인장비의 경추간반에 대한 견인효과의 MRI 연구 정태섭 1) , 강성웅 2) , 나영무 2) , 박준수 2) , 박창준 3) 1) 연세의대 진단방사선과 , 방사선의과학연구소 2) 연세의대 재활의학과 3) 에어트랙의과학연구원. 목적 : 경추간반 탈출증환자등에 있어서 휴대용 경추용 외부착용 공기견인장비의 경추간반에 대한 견인효과를 MRI 를 이용하여 확인하고자 하였다. 대상 및 방법 : 총 20 명 : 정상인 : 6 명

Download Presentation

휴대용 공기견인장비의 경추간반에 대한 견인효과의 MRI 연구 정태섭 1) , 강성웅 2) , 나영무 2) , 박준수 2) , 박창준 3)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 휴대용 공기견인장비의 경추간반에 대한 견인효과의 MRI연구 정태섭1), 강성웅2), 나영무2), 박준수2), 박창준3) 1) 연세의대 진단방사선과, 방사선의과학연구소 2) 연세의대 재활의학과 3) 에어트랙의과학연구원

  2. 목적: 경추간반 탈출증환자등에 있어서 휴대용 경추용 외부착용 공기견인장비의 경추간반에 대한 견인효과를 MRI를 이용하여 확인하고자 하였다.

  3. 대상 및 방법: 총 20명: 정상인: 6명 경추간반 탈출증 환자: 12명 경추간반 퇴행성 병변 환자: 2명 AirTrac: 경추용 ( Air pressure : 0.4Kgf/cm2 = Traction force : 13.75Kg ) MR Machine: Siemens Vision 1.5T

  4. AirTrac: 0.4Kgf/cm2 Neutral position 288771JSYU

  5. AirTrac: 0.4Kgf/cm2 Neutral position 288771JSYU

  6. Neutral position AirTrac: 0.4Kgf/cm2 288771JSYU

  7. Neutral position AirTrac: 0.4Kgf/cm2 1069147EHSHIM(22)

  8. Neutral position AirTrac: 0.4Kgf/cm2 1069147EHSHIM(22)

  9. Neutral position AirTrac: 0.4Kgf/cm2

  10. Neutral position AirTrac: 0.4Kgf/cm2

  11. Neutral position AirTrac: 0.4Kgf/cm2

  12. Neutral position AirTrac: 0.4Kgf/cm2 1095002HKCHOI(25)

  13. Neutral position AirTrac: 0.4Kgf/cm2 1095002HKCHOI(25)

  14. Neutral position AirTrac: 0.4Kgf/cm2 1095002HKCHOI(25)

  15. Neutral position AirTrac: 0.4Kgf/cm2 1095002HKCHOI(25)

  16. AirTrac: 0.4Kgf/cm2 1095002HKCHOI(25) Neutral position

  17. Neutral position AirTrac: 0.4Kgf/cm2 578643OHNo(1)

  18. Neutral position AirTrac: 0.4Kgf/cm2 578643OHNo(1)

  19. Neutral position AirTrac: 0.4Kgf/cm2 800131CKKweon(17)

  20. Neutral position AirTrac: 0.4Kgf/cm2 800131CKKweon(17)

  21. Neutral position AirTrac: 0.4Kgf/cm2

  22. Increased Height of Cervical Spine during AirTraction Response Height Normal (n=6) 6/6 1.5-4.5 (2.8) HCD (n=12) 8/12 1-9 (2.3) DegCD (n=2) 1/2 0-3 (1.5) (mm)

  23. Reduction of Cervical Disk during AirTraction Complete 2 Moderate 4 Mild 2 (n=8)

  24. 결론: 1. 휴대용 공기견인장비의 경추간반에 대한 견인효과를 경추간반 병변환자 14명중 9명(64%)에서 확인할 수 있었다. 2. 경추간반 탈출증환자 12명중 8명(66%) 에서 견인효과로 경추간반 탈출이 정복되거나 감소되는 것을 확인할 수 있었다.

More Related