WIDE FIELD COMPACT DETECTOR FOR HARD X-RAY POLARIZATION MEASUREMENTS

WIDE FIELD COMPACT DETECTOR FOR HARD X-RAY POLARIZATION MEASUREMENTS.

hastin
Download Presentation

WIDE FIELD COMPACT DETECTOR FOR HARD X-RAY POLARIZATION MEASUREMENTS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WIDE FIELD COMPACT DETECTOR FOR HARD X-RAY POLARIZATION MEASUREMENTS J.-P. Vialle 1, W. Hajdas2*, N. Produit 3, F. Barao 4, C.Casella 5, K.Deiters 2, S. Deluit 3, C. Leluc 5, A. Mschedlishvili 2, M. Pohl 5, D. Rapin 5, E. Suarez-Garcia 2, R. Walter 3, C. Wigger 2 and A. Zehnder 2 1LAPP/IN2P3/CNRS, Annecy, France 2PSI, Villigen, Switzerland; 3ISDC, Universite de Geneve, Switzerland; 4LIP, Lisboa, Portugal; 5DPNC, Universite de Geneve, Switzerland; * Most of this talk comes from W. Hadjas. Many thanks to him

  2. INTRODUCTION • Polarization observations in -rayswere mostly neglected • Most of the missions had difficulties with unambiguous measurements • Recent reports of high polarization in GRB (RHESSI) alerted the community • Present GRB data cannot pin down its mechanism • Large set of observations, including energy and time dependence, is needed • Several new polarimeters are either under construction or being studied !

  3. GRB POLARIZATION • Fireball Model high values excluded Plin ~ 10-20 % • Cannonball Modelfull range possible Plin = 0 - 100% (depends only on .) • Electromagnetic Modelwell defined, moderate Plin ~ 50 % From M.Lyutikov, 2003 See papers discussing various models:T.Piran, A.Dar & A. De Rujula, M.Lyutikov, D.Eichler, G.Ghisellini, D.Lazzatti, M.Medvedev, E.Rossi etc. Polarization measurement should be added to priority programs for GRB’s

  4. OTHER POLARIMETER PROJECTS • GRAPE Gamma Ray Polarization Experiment: Low Z - high Z hybrid, 50-300 keV; M.McConnell et al. • PoGO Polarized Gamma-ray Observer: phoswich of slow-fast units with AC, 30-100 keV; T.Mizuno et al. • SGD Soft Gamma-ray Detector: Compton telescope of Si-strips and CdTe pixels and AC, E<300 keV; H.Tajima • CIPHER Coded Imager and Polarimeter for High Energy Radiation: CdTe array, E<1 MeV; R.Curado da Silva • RHESSI High Energy Solar Spectrometric Imager: 9 large Ge, active/passive modes, E>10 keV; M.McConnell, C.Wigger • Coronas-F, INTEGRAL, etc.

  5. DETECTOR REQUIREMENTS • Designed for polarization measurement only • Simple measurement of polarization with compact instrument • optimized for GRB observations • Relies on given burst position and spectrum (GCN, extra det.) • Large area, large modulation factor and wide field of view • Utilizes large angle Compton scattering, (tolerates small one) • Signal to background ratio to be carefully studied and optimized

  6. POLAR DETECTOR • 48x48 uniform scintillator array • Light, fast and low Z plastic • Tests and prototype with BC400: rad-hard and chemically stable • Element size for study: 4x4x200 mm3; matches space-used MAPM H6568 • Final version size 6x6x200 mm3;fits new MAPM H8500 • Optical insulation and thin (≈ 1 mm) carbon fiber outside shielding • No active shielding; but outer layers can be used if needed

  7. MC SIMULATIONS and RESPONSE MATRIX • GEANT4 package (CERN) • Target size 192x192x200 mm3 • Carbon shield outside/top and dummy MAPM/electronics below • Total mass less than 12 kg • Polarized photon flat field • Angles:  =(0,70), =0, 45 • Energies: single or Band-like (=-1, =-2, Epeak=200 keV) • Dominance of Compton events (and photon escape) observed

  8. MULTIPLICITY and TRIGGER CONCEPT • Most photons deposit energy in several bars • Threshold set at Emin= 5 keV • Upper threshold Esum< 300+ keV (TBC) • Trigger activation: at least 2 channels • Selection of two highest E deposits • Reacting pixels define geometry • Further (on/off-line) cuts possible

  9. POLARIZATION RESPONSE • Analysis uses two largest energy deposits with Ethr= 5 keV • GRB position is known (e.g. GCN) • Fit function: N=A·cos(2(-0)+½)+B • Parameters:100=A100/B100 - modulation factor for 100% polarization0 – polarization direction • MC predicts clear modulation signal • Unpolarized photons create pattern with period /2

  10. MODULATION FACTOR • Peak 100reaches about 40% • High plateau between 100 and 250 keV; • Lower energy threshold around 35 keV; no limits for higher one • Constant values kept up to = 30 for off-axis GRB • 30% sky coverage possible • 100 values comparable with other polarimeters

  11. EFFECTIVE AREA and FIGURE OF MERIT • Maximum effective area ·A = Aeff≈ 200 cm2 for 4x4 mm2 bars • Aeff ≈ 80 cm2 – 22% of total area for Band-like spectrum • Polar angular dependence varies within 15% only • Increase by a factor of 2 for bar size 6x6 mm2 • Figure of merit FoM =B – background rate replaced by detector volume (scaling) • Effective X-ray energies < 50 keV

  12. BACKGROUND SOURCES • Cosmic rays removed by upper energy threshold • No measurements inside belts though discrimination possible • Diffuse background E,bg>10 keVFdif=2.46 /cm2/sr/s – 430 coinc./s • Non-GRB  sources – e.g. CrabFCrab=0.7 /cm2/s • S/C induced ’s – ISGRI estimated Find=0.02 /cm2/sr/s • Weaker GRBs specially at lower energies background dominated

  13. MINIMUM DETECTABLE POLARIZATION • MDP = B - background rates from S/C induced and diffuse ≈ 500 s-1 n= 3, Aeff = 100 cm2, 100 = 30%,T = 0.3, 20 s (short/long GRB) S – signal rate from Band spectrum EPeak= 320 keV, = -1.6, = -2.5 • E=10-5 erg/cm2→ MDP3≈ 10%example LTC GRB060418 by RHESSI • Several measurements per year !

  14. TESTS WITH 16 SMALL BARS (4x4 mm2) • 4x4 flat MAMP H6568 (Hamamatsu) • BC400 plastic bars 4x4x200 mm3 • Bicron 620 reflective paint • 241Am (59keV) and 57Co (122 keV) radioactive sources • Charge sensitive ADC CAMAC • Large attenuation of the pulse high amplitude along the bar length • Pulse height variations among anodes within a factor of 2

  15. TESTS WITH 8x8 BARS (6x6 mm2) • Single module assembly with 6x6x200 mm3 BC400 plastics • Teflon wrapping and Al foil isolation of each bar • Coupling to H8500 8x8 MAPM (pitch 6 mm, anode size 5.8 mm) • XY table and sources tester • The same DAQ as for 4x4 mm2 bars • Mono-energetic fluorescence sources exposures (6-44 keV)

  16. THRESHOLD and NON-UNIFORMITY Teflon wrapping • Signal top/bottom ratio 1.31 • Amplitude variations among anodes by ½ (factory ⅓) • Threshold 5 keV feasible Signal with sources: Rb at 13.4keV & Ag at 22.2keV • New test with Al wrapping • Signal top/bottom ratio 1.19 • Signal higher by 20% wrt Teflon

  17. -RAY POLARIZER and ASYMMETRY DATA • Simple -ray polarizer constructed • 90 scattering of photons on large scintillator • Strong 137Cs source (37 MBq) • Collimated, partially polarized -rays (E90deg≈ 290 keV, Pmax≈ 60%) • Triple coincidences for trigger • Coincidence pattern and CS ADC readout (CAMAC) • Asymmetry up to 12% depending on distance between plastics; draft data

  18. IN PREPARATION: FAST and SLS • FAST (Muon lifetime experiment at PSI) equipment available from this summer on • Detector equivalent to smaller POLAR:- 12.8 x 19.2 x 20 cm3 scintillator array- 1536 BC400 bars (4 x 4 x 200 mm3) - 96 H6568 MAPM • DAQ: FD, TAC, event-by-event • Test with polarized -rays from source • PSI SLS synchrotron polarized -rays • Various energies up to many tens keV • 8x8 detector array (6x6x200 cm3) tests

  19. SUMMARY • POLAR – Compton hard X-ray GRB polarimeter using low Z scintillators • 48x48 homogeneous array of 6x6x200 mm3 plastic bars • FoV ≈ ⅓ of the sky and low energy threshold Emin < 50 keV • Aeff≈ 200 cm2 and 100≈ 40% at 200 keV • MDP3≈ 10% for GRB total energy of 10-5 erg/cm2; tens of detections/year • First asymmetry results obtained demonstrating polarimetric capability • Discussions underway to include POLAR in forthcoming satellite experiments

  20. LIGHT COLLECTION WITH WS-FIBERS • Wavelength shifters implementation across the bar length • Bicron BC620 with diameter 1 mm, glued using BC600 optical cement • Two shifter fibers per plastic bar • Overall double coat reflective paint • Good signal uniformity obtained • Active volume reduction by 12%

  21. Band parametrization of GRB’s Energy spectrum GRB 990123

  22. Polarization and Compton scattering