1 / 21

Low Energy Positron Polarimetry for the ILC

Low Energy Positron Polarimetry for the ILC. Sabine Riemann (DESY) On behalf of the LEPOL Collaboration. Outline. L ow E nergy Pol arimeter (LEPOL) Task within EUROTeV WP4 (Polarized Positron Source) Why & where do we need it ? - Available processes  Polarimeter options

havens
Download Presentation

Low Energy Positron Polarimetry for the ILC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Low Energy Positron Polarimetry for the ILC Sabine Riemann (DESY) On behalf of the LEPOL Collaboration LEPOL

  2. Outline • Low Energy Polarimeter (LEPOL) • Task within EUROTeV WP4 (Polarized Positron Source) • Why & where do we need it ? • - Available processes  Polarimeter options • - Our suggestion: Bhabha polarimeter • - Backup: Compton Transmission Polarimeter • - Summary LEPOL

  3. Measurement of positron polarization at the source  Control of polarization transport  Optimization of positron beam polarization  Commissioning Desired: non-destructive method with accuracy at few percent level LEPOL

  4. e+ Polarisation Measurement near the source Polarization measurement  measure asymmetries ! Find a process with • sensitivity to longitudinal polarization of positrons (electrons) • good signal/background ratio • significant asymmetry In the energy range 30 MeV … 5000 MeV Desired: non-destructive easy to handle fast (short measuring time) e+ beam parameterse+ / bunch Ne+ 2·1010 bunches / pulse 2820 Rep. Rate R 5 Hz Energy E 30 – 5000 MeV Energy spread ΔE/E 10 % Normalized emittance ε*~ 3.6 cm rad Beam size σx,y ~ 1 cm LEPOL

  5. Considered Processes • Compton Scattering (ex.: SLC, HERA) • Laser backscattering on beam • Preferred polarimeter option at IP • Not an option for the LEPOL (very small rates due to large beam size) • after damping rings beam size smaller  this option is under study by Tel Aviv U (G. Alexander) • But: very far from source • Mott • Transverse polarized positrons • sMott~E-4 sMoller~E-2 sBhabha~E-2  high background at relevant energies LEPOL

  6. Considered Processes • Compton Transmission (ex.: E166, ATF) • Reconversion of e+ to g in target • Polarization dependent transmission of g through magnetized Fe • Small, simple setup • Can deal with poor beam quality • Destructive  Beam absorbed in relatively thick target • Less efficient with increasing beam energy (E < 100 MeV) LEPOL

  7. Considered Processes • Synchrotron radiation (ex.: VEPP-4 storage ring) (S.A. Belomestnykh et al., NIM A 227 (1984) 173 • Transverse polarization needed • Angular asymmetries of synchrotron radiation in damping ring • Relative simple setup • Non-destructive, non intrusive • Very small signal: Asymmetry < 10-3 • position far from source LEPOL

  8. Considered Processes • Laser Compton Scattering • Compton Transmission Experiment • Mott Scattering • Synchrotron radiation • Bhabha/Møller magnetized iron target; e- polarization in Fe: ~7%, angular distribution of scattered particles corresponds to e+ polarisation LEPOL

  9. Bhabha Polarimetry • As Møller polarimeter already widely used (SLAC, VEPP) • Cross section: • maximal asymmetry at 90°(CMS) ~ 7/9 ≈ 78 % • e+ and e- must be polarized Example: Pe+=80%, Pe-=7% Amax ~ 4.4 % LEPOL

  10. Bhabha Polarimetry Working point: • After pre-acceleration 125 MeV – 400 MeV • First design studies done for 200 MeV Used for simulations: Polarized GEANT4, release 8.2 contact: A. Schälicke and collaborateurs, http://www-zeuthen.desy.de/~dreas/geant4 LEPOL

  11. Studies for a Bhabha Polarimeter Ebeam = 200 MeV DEbeam = ±10% 2·108 positrons ang. spread =±0.5o 80 mm Fe target PFe = 100% Pe+ = 100% electrons(+) electrons(-) positrons photons after Bhabha scattering LEPOL

  12. Regions of maximum asymmetry LEPOL

  13. Bhabha Polarimeter 50MeV < E < 150 MeV 20MeV < E < 150 MeV 0.04 < q < 0.120 0.04 < q < 0.120 LEPOL

  14. Bhabha Polarimeter LEPOL

  15. Bhabha Polarimeter Significance - Energy range: 50 – 150 MeV 20 – 150 MeV cosθ: 0.04 – 0.12 rad 0.04 – 0.21 rad LEPOL

  16. Photon distributions cosθ: 0.08 – 0.4 rad no energy cut LEPOL

  17. Bhabha Polarimetry • Best significance using asymmetries of scattered Bhabha electrons • Working point: • After pre-acceleration and separation of e+ beam: 120 MeV – 400 MeV • Asymmetries: • Detection of scattered Bhabha electrons is sufficient • Detection of scattered Bhabha positrons for checks • Use of photons (annihilation in flight) Conclusion for layout • Separation of energy range  spectrometer • Separation of e+ and e-  magnetic field (spectrometer • Separation of angular range  masks • Target LEPOL

  18. spectrometer mask, shielding exit window (?) detector Side view e+ e+ ~2.5m ~5m Angular range large enough  no bend needed to kick out the scattered e-,e+,g Detector size: O(40*60 cm2) signal rate: O(109) per second for 80 mm Fe foil top view higher energy, lower q electrons positrons photons +background lower energy, higher q LEPOL

  19. Magnetized Iron Target Target temperature vs. time Heating of the target -> Magnetization decreases • Simulation for 30 µm • Cooling by radiation • TC (Fe) = 1039 K; melting point 1808 K Ongoing considerations on target layout • ΔT ΔM ΔP ΔAsy • Magnetization (monitoring, tilted target?) • Cooling in real Multiple scattering  additional angular spread of ≤4% Magnetisation vs. Temperature LEPOL

  20. Compton Transmission Method ? • Destructive ! • Working point: Ee+ < 100 MeV ideal after capture section O(~30 MeV)  Dimensions O(1m)  Experiences from E166, ATF  Thick Target (1 to 3 X0), with high energy deposition O(~kW)  Small asymmetries O(<1%) at higher energies Example: Ebeam 30 MeV, Pe-=7.92%, Target: 2X0 W, Absorber 15cm Fe A(Pe+=30%) ~ 0.4% A(Pe+=60%) ~ 0.8% LEPOL

  21. Summary Recommended for polarimetry near the source – but not yet tested: Bhabha polarimeter at ~400 MeV • In principle, the Bhabha polarimeter could work during ILC operation • Backup possibility: Compton Transmission • After DR: Compton polarimeter To be discussed: - where will we need to check the e+ pol? - when? Commissioning/ operation  type of polarimeter Our plan: Finalize the design study, think about target tests, suggest a polarimeter design LEPOL Collaboration: DESY: K. Laihem, S. Riemann, A. Schälicke, P. Schüler HU Berlin: R. Dollan, T. Lohse NC PHEP Minsk: P. Starovoitov Tel Aviv U: G. Alexander LEPOL