A BRIEF INTRODUCTION TO FIELDBUS

4. hf. NETLOGIC. A BRIEF INTRODUCTION TO FIELDBUS. TRADITIONAL CABLING SYSTEM . PLC. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. TERMINAL BOARD. FIELDBUS SYSTEM. PLC MASTER. OUTPUTS. I/O SLAVE. CAMPO. FIELD. INPUTS. FIELDBUS COMMUNICATION. NETWORK INPUTS (ALL) POLLING.

hawa
Download Presentation

A BRIEF INTRODUCTION TO FIELDBUS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 4 hf NETLOGIC A BRIEF INTRODUCTION TO FIELDBUS

  2. TRADITIONAL CABLING SYSTEM PLC 1 2 3 4 5 6 7 8 9 10 TERMINAL BOARD

  3. FIELDBUS SYSTEM PLC MASTER OUTPUTS I/O SLAVE CAMPO FIELD INPUTS

  4. FIELDBUS COMMUNICATION NETWORK INPUTS (ALL) POLLING I/O SLAVE (1) MASTER Output 1 Completed Communication (with address) OUTPUT Order: Slave address (2) Output address (3) Output 2 Each Inputs has: Slave address(2) Input address(1), (2) Master receives Addressed Inputs From the field (input 1, slave 2) I/O SLAVE (2) Output 3 SLAVE NODE Input 1 Input 2 I/O SLAVE (3)

  5. 4 hf NETLOGIC FIELDBUS FEATURES

  6. FIELDBUS FEATURES • no input & output cabling to PLC • each slave node needs to be addressed • communications diagnostic available • easy network plug & play expansibility • high number of I/O through a single PLC • guaranteed transmission speed • PLC is always isolated from the field • (PLC supplies the field-bus only)

  7. 4 hf NETLOGIC Vesta Fieldbus

  8. 4 hf NETLOGIC I/O SLAVE NODE OUTPUT = 4HF SOLENOIDS INPUT = 24V DC DIGITAL SIGNALS

  9. THE SYSTEM VESTA SLAVE NODE (UNCABLED Input e Output) CABLES WITH PLUGS Snap M8 NON CABLED PLC

  10. INTERFACES 24V DC POWER SUPPLY MASTER PLC INTEGRATED SLAVE

  11. 4 hf NETLOGIC 4hfNETLOGIC ELEMENTS FEATURES

  12. I/Os Outputs (solenoids) max = 128 Inputs max = 128 HEAD ISLAND Up to 32 Solenoids (16 valve stations) EXPANSION ISLAND Up to 16 solenoids (8 valve stations) Up to 6 expansion islands (32+6x16=128 solenoids) DIGITAL INPUTS BOX (24V DC) Up to 8 inputs Up to 16 Input BOXES (8x16=128 Input)

  13. VESTA SLAVE NODE EXAMPLE Y cable for input boxes connection Y cable for expansions connection

  14. ADDITIONAL OUTPUTS ADDITIONAL 24V DC POWER SUPPLY SUB-D 9 PLUG FOR EXPANSION ISLANDS N°8 DIGITAL OUTPUTS SNAP M8 CONNECTOR 10Watt FOR OUTPUT

  15. DIAGNOSTIC MIF CABLE (MONITOR INTERFACE) PC NODE ADDRESSING NODE DIAGNOSTIC (ADDRESS, N° OUTPUT, N° INPUT) REMOTE CUSTOMER SUPPORT INTERNET

  16. SUPPORTED PROTOCOLS Ethernet IP, Modbus TCP

  17. 4 hf NETLOGIC 4hfNETLOGIC FEATURES

  18. 4 hf NETLOGIC • EASY NODE ELEMENTS CONNECTION • (EXPANSIONS, DIGITAL INPUTS BOXES) • WITH PLUGGED CABLES (PLUG & PLAY). • SERIAL COMMUNICATION AMONG 4HF • NETLOGIC AND NODE ELEMENTS. • AUTOMATIC I/O ALLOCATION TO THE • 4HF NETLOGIC CHIPSET • EXPANSIONS & DIGITAL INPUTS BOXES • ARE 4HF NETLOGIC SERIES ONLY

  19. 4 hf NETLOGIC • MAX 128 OUTPUT, MAX 128 INPUT • MAX CABLES LENGHT (INPUTS & EXP.) = 5 M • MAX SPEED AVAILABILITY FOR EACH • PROTOCOL • NODE DIAGNOSTIC THROUGH MIF CABLE • CE MARKING (89/336/CE) • WORKING TEMPERATURE = -10°/ +50° C

  20. VESTA AUTOMATION S.R.L. Via Martiri di Belfiore, 69/A 45100  ROVIGO, ITALY Web: www.vesta.it Thank you. SALES INTERNATIONAL Tel.+39 0425 474313 Fax +39 0425 474670 Email: export@vesta.it