P-14054 Smoking machine . Chris Boise Eric Cawley Gideon Oladunjoye Jose Pardes Matt Cross Megan Guarnieri Cleary. Overview. Problem Statement Customer/Engineering Requirements System Overview Final Design Problem Tracking Current State Test Results Future Tasks.

helga
Download Presentation

P-14054 Smoking machine

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. P-14054 Smoking machine Chris Boise Eric Cawley Gideon Oladunjoye Jose Pardes Matt Cross Megan Guarnieri Cleary

  2. Overview Problem Statement Customer/Engineering Requirements System Overview Final Design Problem Tracking Current State Test Results Future Tasks

  3. Problem Statement In order to simultaneously collect emissions and transport undisturbed casts for analysis, current hollow cast models will be combined with the existing side stream smoking machine. Device will operate using acquired data from the wPSMD. Unit needs to be self-contained, portable, fit on a workbench, and user friendly. The unit must also be production ready for identical machines in other labs. During operation smoke needs to be ventilated responsibly and the unit must be interfaced with LabVIEW.

  4. Customer Requirements

  5. Engineering Requirements

  6. System Overview

  7. System Overview

  8. Final Design

  9. Final Design Electronic cigarettes 2 syringe pumps Sliding access door No filter between chimney and impinger No pressure or temperature sensors Limit switches Termination and reset program Overhead exhaust vent H-bridge with protection Larger DAQ interface

  10. Problem Tracking

  11. Current State Proven results for research cigarettes Electronic cigarettes capable Lung cast produced and all parts delivered Internal lung cast pressure program Labeling all required parts and wires Program reset Customer documentation

  12. Test Results 36 Total Research Trials (1R5F) Eliminated non-7 puff trials and anything with percent error > +/-70% Resulted in 15 samples TPM avg.= 2.145 mg % Error avg.= 3.13%

  13. Test Results

  14. Future Tasks Fix/reduce actuator creep through LabVIEW or limit switches Automated puffing profile from WPSM device Calibrated/verify puff using flow meter Automated parallel correction to puffing profile Lung cast deposition incorporation Puff selection drop-down menu

  15. Summary Problem Statement Customer/Engineering Requirements System Overview Final Design Problem Tracking Current State Test Results Future Tasks

  16. Questions?