1 / 21

Iowa Nutrient Load Estimations for Point and Non-point Sources

Iowa Nutrient Load Estimations for Point and Non-point Sources. Iowa DNR November 14, 2012. DNR Staff. Jackie Gautsch, Watershed Monitoring Rick Langel, Watershed Monitoring Mary Skopec, Watershed Monitoring Keith Schilling, Geology and Groundwater Steve Williams, Wastewater

helia
Download Presentation

Iowa Nutrient Load Estimations for Point and Non-point Sources

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Iowa Nutrient Load Estimations for Point and Non-point Sources Iowa DNR November 14, 2012

  2. DNR Staff • Jackie Gautsch, Watershed Monitoring • Rick Langel, Watershed Monitoring • Mary Skopec, Watershed Monitoring • Keith Schilling, Geology and Groundwater • Steve Williams, Wastewater • Adam Schnieders, Wastewater • Calvin Wolter, GIS

  3. Iowa’s Ambient Monitoring Network • 98 Sites throughout State • Includes Sites Upstream and Downstream of Urban Centers • Monitored monthly • Mostly paired with USGS Gage locations • Data from 2000-2010

  4. Stream Load Estimation Methods • AutoBeale, Pete Richards, 1998 • Load Estimator (LoadEst), Rob Runkel, USGS, 2004 • Mean Value

  5. AutoBeale Method • Method that uses a ratio of load to flow to estimate missing data • Data for 2003 Nutrient Budget • Data from 2000-2002 • 71 Sites

  6. LoadEst Method • Method that uses a regression model incorporating flow and time to estimate missing data • Data from 2000-2010 • 77 sites estimated

  7. Mean Value • Data from 2000-2010 • Mean value for NO3-N and Total P from all samples • Mean flow rate from USGS gages • 77 sites evaluated

  8. Check for Unreasonable LoadEst Values • More than +/- 15% of Mean Value loads • Residual error more than +/- 2.0 • Error ratio > 10 • NO3-N concentration > 25 ppm • Total P concentration > 10 ppm • Check hydrograph vs. sample date to see if full range of flows sampled

  9. Final Load Estimates • Use acceptable LoadEst models (59 for Nitrate, 51 for Total P), • AutoBeale models (71) • Mean Value models (77) • Average of all models available (77 sites)

  10. Total N and P Loads • Sum up loads for 24 outer basins • Total N = NO3-N/0.82 • Sum area of outer basins (83% of state) • Scale up to State area

  11. Point Source Load Calculation • For 102 Major Municipal and 28 Industrial Facilities • Load = Flow * Concentration • Use Average Annual Flow = 2/3 Wet Weather Design Flow • Use 25 ppm N and 4 ppm P in discharge from “Wastewater Engineering” Metcalf & Eddy

  12. Non-point Source Calculation • Total State Load minus Point Source Load

  13. Point Source Biological Nutrient Removal • For 102 Municipal and 28 Industrial Major facilities • Assume concentration reduction for TN from 25 mg/l to 10 mg/l • Assume concentration reduction for TP from 4 mg/l to 1 mg/l • Use Average Annual Flow = 2/3 Wet Weather Design Flow

  14. Point Source Biological Nutrient Removal • Total N Point source reduction = 11,000 tons/year (4% of Total N stream load) • Total P Point source reduction = 2,170 tons/year (16% of Total P stream load)

  15. Non-point Source Reduction needed to meet 45% goal • Non-point Source TN reduction needed = 45%-4% = 41% or 115,000 tons Total N • Non-point Source TP reduction needed = 45%-16% = 29% or 4,040 tons Total P

  16. Summary • Stream load estimation process could be improved by tailoring the monitoring schedule to better meet the needs of load estimation programs • Point source load estimations could be improved by requiring nutrient sampling and obtaining flow data