Hotel Group BASE CASE Energy savings that matter – one hotel floor only.

Hotel Group BASE CASE Energy savings that matter – one hotel floor only. 251 halogen globes a(40W) re replaced with Ecoglow LED globes (4.5W). Average on time was taken to be 10 hours a day, 5 days per week, 2,600 hours per year.

helki
Download Presentation

Hotel Group BASE CASE Energy savings that matter – one hotel floor only.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hotel Group • BASE CASE • Energy savings that matter – one hotel floor only. • 251 halogen globes a(40W) re replaced with Ecoglow LED globes (4.5W). • Average on time was taken to be 10 hours a day, 5 days per week, 2,600 hours per year. • The LED globe retrofit results in a total saving of over $42,000 over a 10 year period. • Benefits: • Payback inside 12 months • 88% energy and carbon reduction • Reduced maintenance costs • Lower carbon tax impost • Note: No labour replacement costs have been included in these energy saving calculations. • Assumptions: • $0.092 per kWh • 2,600 hours per year per globe • Carbon tax valued at $25/T • CO2 consumption = 0.95kg CO2p/kWh • Theoretical example – applications may vary.

  2. Hotel Group • SENSITIVITY ANALYSIS • Energy savings that matter – one hotel floor only. • 251 halogen globes (40W) are replaced with Ecoglow LED globes (4.5W). • Average on time was taken to be 12 hours a day, 5 days per week, 3,120 hours per year. • The LED globe retrofit results in a total saving of over $55,000 over a 10 year period. • Benefits: • Payback inside 10 months • 88% energy and carbon reduction • Reduced maintenance costs • Lower carbon tax impost • Note: No labour replacement costs have been included in these energy saving calculations. • Assumptions: • $0.11 per kWh - +20% INCREASE • 3,120 hours per year per globe - +20% INCREASE • Carbon tax valued at $25/T • CO2 consumption = 0.95kg CO2 p/kWh • Theoretical example – applications may vary.