An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AnruierRIGID TRANSPORTABLE SHELTERS

  2. Preface

  3. Our missions

  4. Our products

  5. Shelter classification Standard rigid shelters • High structural strength, made from heavy-duty insulation aluminum panel and extrusion, can be used as a independent unit. • Small size, light weight, easy to hide, configured with plug and play power outlets, internet access, air conditioners. working conditions are comfortable. • Easy to disassemble and installed. It can be deployed by hand tools within 10 minutes and suitable for various transportation modes and has good strategic mobility • High generalization, serialization, and standardization

  6. Shelter classification Combined shelters • Main materials: carbon fiber, glass fiber, aramid honeycomb and aluminum honeycomb, shielding material, etc. • High load to weight ratio and suitable for mini systems with high mobility. • Other functions such as automatic balance system, automatic shelter lifting system, internal control system, etc can be integrated according to customer requirements to meet various customer needs.

  7. Shelter classification Special shaped shelters • Non-standard rigid shelter, applied for the customer with special desire for outer shape, deliver limitation, compact or complex system layout, or radar stealth. • We will give flexible solutions for any customer’s any demands. Your job is only description, the following work and remaining time will be ours.

  8. Shelter classification Expandable shelters • Mode: single-side expansion, double-side expansion, multiple expansion. • Expanding way: withdrawal, overturn. • Transmission: by power, by hand, by fluid.

  9. Shelter classification Expandable shelters(combined ones) • By withdrawal or overturn, you can combine more shelters to get more space and function. • The smart designed connecting parts fixed on the wall can help you to combine the shelters easily, even you can get a house with courtyard as you wish. • Applicable to: field command post, hospital, temporary hangar, VIP lounge, etc.

  10. Shelter classification Special shelters(mini) • A mini shelter tailored for customer with special purpose is usually mounted on small four-wheel vehicles. • It is suitable for temporary command center of a small unit , mobile communication and detection nodes, etc.

  11. Shelter classification Special shelters(middle-sized)

  12. Shelter classification Special shelters(big sized)

  13. Shelter classification Special shelters(towed ones)

  14. Main technical parameters External size

  15. Main technical parameters Environmental adaptation • Temp:Job:-45℃ ~ 55℃ • storage:-55℃ ~ 70℃ • It has the functions against solar radiation, earthquake impact, damp heat, mould, salt spray, sand and dust.

  16. Main technical parameters • Airtight: Up to 300Pa over pressure, the air leakage will be 0.1 ~ 6 m3/min inside the shelter. Sealing property • Light: anti direct light leak out of the shelter. • Insulation performance: when the temperature gap between inside and outside up to 55°C, the heat transfer coefficient is 1.2 to 2.5 W/(m2°C) • Water seal:endure the 6mm/min rain last 1 hour time.

  17. Main technical parameters Electromagnetic shielding • High shielding effectiveness body: within the frequency range of 0.01 ~ 18000MHz, the shielding effectiveness is not less than 60dB. • In the 0.01 ~ 18000MHz frequency range, the shielding efficiency can reach up to 80dB or more. • Avoid external electromagnetic environment interfere on board equipment and protect the inside equipment or cover electromagnetic leakage to the outside (to get rid of enemy detection), and improve the system stability and survival ability, and is suitable for the important electronic equipment, system integration, etc

  18. Main technical parameters. Load ability • The plate can bear the 1KN ~10KN load as point load, concentrated load and uniform load. • Reinforcement for the inside equipments is available depend on buyers desire. • Crane lifting or helicopter hoisting is available.

  19. Main technical parameters. Electrical safety. • A/C filter • Leak current protection • High voltage protection • Leak voltage protection • Ground wire alarm • Lighting protection. Improve the electrical safety of person and instruments.

  20. 主要技术指标 Bullet proof and explosion proof • With internal protection and external protection, draping protection and other ways for protection. • Bullet-proof treatment of key parts such as cab, chassis oil / gas road, windows, member positions and so on. • It is suitable for mobile command post, important electronic equipment carrier, mine lifesaving and other fields.

  21. Main technical parameters. Invisibility • All kinds of anti infrared and visible camouflage paint (Southern Woodland Camouflage, digital camouflage, etc.) are coated on the surface of the shelter with visible camouflage and near infrared camouflage capability. • The body structure electromagnetic shielding was treated, the electromagnetic leakage was reduced. • Radar wave stealth coating was coated on outside surface of the shelter or the installed radar wave absorbing materials to reduce the locking possibility by space-based / ground-based radar and to evade the attack from the guided weapons.

  22. Main technical parameters. Transportability

  23. Main configurations. Exterior Top cover Door Wall box Stairs to top Elevator mechanism. A/C Shelter ladder Corner module

  24. Main configurations Lightingrod. Exterior Outdoor lights Lifting poker Guard bar Window Shelter apron Window-blinds

  25. Main configurations Exterior Lifting support leg. Road wheel Leveling system leg

  26. Main configurations Interior A/C air duct Command consoles Curtain Thermo-hygrometer Seats Work bench body Power distribution system Turning work bench

  27. Main configurations Interior Elevator mechanism Display-control consoles Power sets

  28. Main configurations Internal Switch box Emergency light Switch and socket Tool Fire extinguisher Cupboard Lights Sofa Council board Box base Aviation seats

  29. Main configurations Light:daylight lamp or normal energy saving lamp. Seats:Folded one or fabric cover Interior decoration Decoration:Paint/Boeing film Workbench top:Solid wood. Floor:Casting/rubber/anti-static floor

  30. Main configurations Light:LED lamp or light belt Ceiling:Ceiling/trim Interior decoration Decoration:Al-plastic panel/blister plate. Workbench top: solid wood Floor: Rubber / antistatic / composite floor Seats:Aviation seats or PU surface.

  31. Main configurations Light:LEDlampor light belt Top:ceiling/trim Interior decoration Inner loading: suction board / honeycomb board / soft outfit Workbench top:solid wood Wall:waist line Seats:Aviation seats/pure leather Floor/ Rubber / antistatic / composite floor

  32. Typical application

  33. Typical application Emergency command

  34. Typical application Integrated communications

  35. Typical application Emergency repairs

  36. Typical application Special transports

  37. Typical application Base stations

  38. Typical application Low noise power stations

  39. Customer comments