190 likes | 205 Views
eichrom. TECHNOLOGIES INC. The Determination of 226 Ra in Water Samples. Anil H . Thakkar Eichrom Technologies, Inc. eichrom. TECHNOLOGIES INC. Objective. To design a procedure for radium in water samples using Eichrom’s cation exchange resin and Ln Resin. eichrom.
E N D
eichrom TECHNOLOGIES INC The Determination of 226Ra in Water Samples AnilH. Thakkar Eichrom Technologies, Inc.
eichrom TECHNOLOGIES INC Objective • To design a procedure for radium in water samples using Eichrom’s cation exchange resin and Ln Resin.
eichrom TECHNOLOGIES INC Current Procedure Used • Barium sulfate precipitation • Conversion to BaCO3- tedious and time consuming
eichrom TECHNOLOGIES INC Current Procedure Used • Sample + Ba carrier + Ba-133 + Conc.H2SO4_+ Heat BaSO4 • Precipitate allowed to settle for several hours or overnight • Precipitate collected and converted to BaCO3
eichrom TECHNOLOGIES INC New Approach Water samples Cation exchange resin column Eichrom Ln Resin column
eichrom TECHNOLOGIES INC Preparation of Water Samples • 0.5 L / 1.0 L water samples, acidified to pH 2 • Add 133Ba as a tracer
eichrom TECHNOLOGIES INC Eichrom Cation Exchange Column • Load solution: 0.5 L/ 1.0 L of sample • Rinse with 50 mL of 0.1M HNO3 • Strip Ra and Ba with 50 mL of 8M HNO3
eichrom TECHNOLOGIES INC Preparation of Load Solution for Ln Resin Column • Evaporate eluent from cation exchange column to dryness • Dissolve residue in 10 ml of 0.095M HNO3 acid • Load on Eichrom Ln Resin column
eichrom TECHNOLOGIES INC Ln Resin Column Separation (1) Load: 10 mL of mL 0.095M HNO3, Collect 1) and (2) for Ba & 226Ra (2) Rinse: 15 mL of 0.095M HNO3 (3) Strip: 10 mL of 0.35M HNO3 collect (3) for 228Ac
eichrom TECHNOLOGIES INC 226Ra Via Alpha Spectrometry • Evaporate 226Ra/133Ba fraction to 10 mL volume • Add 3 mL of 40% sodium sulfate, 4 drops of 1:1 acetic acid. Swirl • Add 0.2 mL of seeding suspension. Mix • Place tubes in cold water bath for 30 minutes • Filter on 0.1 micron filters, count via alpha spectrometry
eichrom TECHNOLOGIES INC 133Ba Via Gamma Counter • Count 133Ba tracer yield via gamma spectrometry
eichrom TECHNOLOGIES INC 228Ac Via Gas-Flow Proportional Counter • Add 50 micrograms of cerium carrier • Add 1.0 mL of HF • Filter on 0.1 micron filters • Measure for beta radiation
eichrom TECHNOLOGIES INC 226Ra % Recoveries-0.5L DI Water
eichrom TECHNOLOGIES INC 226Ra Alpha Spectrum
eichrom TECHNOLOGIES INC 133Ba Gamma Spectrum
eichrom TECHNOLOGIES INC 226Ra, 224Ra, and Daughters 224Ra 226 Ra 220Rn 218Po 222Rn
eichrom TECHNOLOGIES INC 226Ra % Recoveries in Tap water
eichrom TECHNOLOGIES INC 226Ra in EPA SampleSept.18, 1998
eichrom TECHNOLOGIES INC Summary • Cation exchange resin option: • provides a good replacement for the time consuming BaSO4 precipitation steps • it eliminates inconsistent metathesis steps • reduces usage of chemicals/reagents • provides consistency and saves time • Acceptable 226Ra recoveries