HCAL – SiPM upgrade requirements Workshop in Trieste on June 2-4 2008 A.H Heering, Boston University
Inside the magnet: HB 144 x 19 channel HPDs (16 layers) HE 144 x 19 channel HPDs (16 layers) Outside the magnet: HO 132 x 19 channel HPDs (1-2 layers) HF 1800 one inch PMTs. HCAL current baseline readout A.H Heering, Boston University
CMS Ring YB0 A.H Heering, Boston University
Test Beam setup • Due to the cosine effect of the Angle we have lowest light in YB1 (YB0 has 2 layers) A.H Heering, Boston University
Developed; Custom FBK SiPM A.H Heering, Boston University
HO with SiPM readout A.H Heering, Boston University
Typical SiPM pulse A.H Heering, Boston University
SiPM-QIE Interface Circuit diagram S. Los (FNAL) • To match the gain of the readout we used a factor of 5 lower couple capacitor • Using R5 we hope to shape the pulse shape and cancel the tails A.H Heering, Boston University
Pulse shape after QIE 1 TS=25 ns A.H Heering, Boston University
2006 First Test Beam results A.H Heering, Boston University
HPD muon in HO YB1 A.H Heering, Boston University
2007 Test beam FBK custom diode (Used cells) A.H Heering, Boston University
2007 Test beam CPTA 2x2 mm diode We used light mixer A.H Heering, Boston University
Linear range is worst then HPD A.H Heering, Boston University
300 GeV pion resolution in 3x3 towers ECAL + HCAL SiPM HPD No indication that late showers give worst resolution as baseline HPD A.H Heering, Boston University
Measured Temperature coefficient A.H Heering, Boston University
Production Cooling and stabilization A.H Heering, Boston University
Radiation study in October 2007 A.H Heering, Boston University
Radiation damage for 240 MeV Protons Custom 6 mm2 FBK SiPM Annealing 1 day 4 doses of 2.5E9 2 doses of 1E10 4 doses of 2.5E9 IRST Sample 1 Total dose of 1E10 p/cm2 IRST Sample 2 Total dose of 3E10 p/cm2 A.H Heering, Boston University
Scope traces during radiation A.H Heering, Boston University
1mm^2 diodes A.H Heering, Boston University
I_leakage vs Ped_rms A.H Heering, Boston University
FBK single cel single PE (pedestal distributions) A.H Heering, Boston University
Damage and QE (one day annealing) T=27 degree C A.H Heering, Boston University
Dead time of micro cells A.H Heering, Boston University
Signal –Pedestal during radiation A.H Heering, Boston University
Signal –Pedestal during radiation Large dead time A.H Heering, Boston University
HB – 1010 n/cm2/ CMS Year HE – 3 * 1010 n/cm2/ CMS Year HO – 109 n/cm2/ CMS Year HF – 1011 n/cm2/ CMS Year Radiation levels in HCAL A.H Heering, Boston University
Dead time shorter?? A.H Heering, Boston University
PDE vs Company HB,HE,HO HF A.H Heering, Boston University
Smaller cells vs Linearity (deadtime!) A.H Heering, Boston University
New devices with 10 micron cells I. Musienko A.H Heering, Boston University