1 / 31

Ventilation / Ventilation Control Tests

Ventilation / Ventilation Control Tests. RET 2414 Pulmonary Function Testing Module 5.0. Ventilation / Ventilation Control Tests. Objectives Calculate tidal volume and minute ventilation Describe two causes of increased ventilation Identify an abnormal V D /V T ratio.

hina
Download Presentation

Ventilation / Ventilation Control Tests

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ventilation / Ventilation Control Tests RET 2414 Pulmonary Function Testing Module 5.0

  2. Ventilation / Ventilation Control Tests • Objectives • Calculate tidal volume and minute ventilation • Describe two causes of increased ventilation • Identify an abnormal VD/VT ratio

  3. Ventilation / Ventilation Control Tests • Objectives • Calculate dead space and alveolar ventilation • Describe one method for measuring breathing response to O2 • Identify the normal breathing response to carbon dioxide (CO2)

  4. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Tidal volume (VT) is • Volume of gas inspired or expired during each respiratory cycle • Respiratory rate (f) • Number of breaths per unit of time • Minute ventilation ( ) • Total volume of gas expired per minute • alveolar ventilation ( ) • dead space ventilation ( )

  5. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation VE = f x VT • Measured with volume displacement or flow-sensing spirometer .

  6. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • VT decreased in: • Severe restrictive patterns • Neuromuscular disorders • Decreased VT is usually accompanied by an increase in respiratory rate in order to maintain alveolar ventilation ( )

  7. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Decreases in both VT and respiratory rate are often associated with respiratory center depression • Alveolar hypoventilation

  8. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Normal respiratory rates ranges: • 10 – 20 breaths/min • Increased in: • Hypoxia • Hypercapnia • Metabolic acidosis • Decrease lung compliance • Exercise

  9. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Normal respiratory rates ranges: • 10 – 20 breaths/min • Decreased in: • Central nervous system depression • CO2 narcosis;a condition resulting from high levels of carbon dioxide in the blood. Confusion, tremors, convulsions, and coma may occur if blood levels of carbon dioxide are too high (>70 mm Hg or higher).

  10. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Normal minute ventilation ranges: • 5 – 10 L/min • When used in conjunction with arterial blood gases, indicates the adequacy of ventilation

  11. Ventilation / Ventilation Control Tests • VT, Rate, Minute Ventilation • Normal minute ventilation ranges: • 5 – 10 L/min • increases in response to: • Hypoxia • Hypercapnia • Metabolic acidosis • Anxiety • Exercise

  12. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • Dead space is the lung volume that is ventilated but not perfused by pulmonary capillary blood flow • Anatomic (conducting airways) VDan • Alveolar (non-perfused alveoli) VDA VDan + VDA = VD • VD(Respiratory or Physiologic Dead Space)

  13. Ventilation / Ventilation Control Tests • Anatomic Dead Space

  14. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • The portion of ventilation wasted on the conducting airways and poorly perfused alveoli is usually expressed as a ratio: VD/VT = (PaCO2 – PECO2)X 100 PaCO2 Modification of Bohr’s equation

  15. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • For convenience VD is often estimated as equal to anatomic deadspace; VD = 1 ml/lb of ideal body weight Valid only if little or no alveolar dead space exists due to pulmonary disease

  16. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • Normal VD/VT ratio in adults: • 0.3 or 30% (0.2–0.4 or 20%–40%) • Increases with: • Pulmonary embolism • Acute pulmonary hypertension • Decreased cardiac output • Decreases with: • Exercise (increase cardiac output and perfusion of lung apices)

  17. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • Alveolar ventilation is the volume of gas that participates in gas exchange in the lungs per minute

  18. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • Alveolar ventilation at rest is approximately 4 – 5 L/min • The adequacy of can only be determined with an arterial blood gas (ABG) Hypoventilation = PCO2 >45 with a pH <7.35 Hyperventilation = PCO2 <35 with a pH >7.45

  19. Ventilation / Ventilation Control Tests • Dead Space /Alveolar Ventilation • Decreased can result from: • Increases in VD • Destruction/dilation airway walls • >FRC (air trapping/hyperinflation) • Bronchodilators • Decreases in

  20. Ventilation / Ventilation Control Tests • Ventilatory Response to CO2 • Ventilatory response to CO2 is a measurement of the increase or decrease in caused by breathing various concentration of carbon dioxide while PaO2 is kept normal

  21. Ventilation / Ventilation Control Tests • Ventilatory Response to CO2 • Procedure • 1-7% CO2 is breathed through either an open or closed circuit while the following are measured: • PeTCO2 • SaO2 • P100

  22. Ventilation / Ventilation Control Tests • Ventilatory Response to CO2 • Normal response to an increased PACO2 is a linear increase in ventilation ( ) • Approximately 3 L/min/mm Hg (PCO2)

  23. Ventilation / Ventilation Control Tests • Ventilatory Response to CO2 • Decreased in patients with: • COPD • Increased airway resistance (Raw) • Lesions in the CNS • Chemoreceptor dysfunction

  24. Ventilation / Ventilation Control Tests • Ventilatory Response to Oxygen • Ventilatory response to O2 is a measurement of the increase or decrease in causes by breathing various concentration of O2 while PaCO2 is kept normal

  25. Ventilation / Ventilation Control Tests • Ventilatory Response to Oxygen Procedure 20%-12% O2 is breathed through either an open or closed circuit while the following are measured: , PaO2, P100, PetCO2 The test is repeated with decreasing concentrations of O2

  26. Ventilation / Ventilation Control Tests • Ventilatory Response to Oxygen • Normal response to a decreasing PaO2 is an exponential increase in ventilation ( ) once the PaO2 is less than 60 mm Hg (SaO2 <90%) 60 torr/90% Saturation O2

  27. Ventilation / Ventilation Control Tests • Ventilatory Response to Oxygen • Significance and Pathology • Patients with obesity-hypoventilation syndrome, obstructive sleep apnea, and idiopathic hypoventilation will show a marked decrease response to hypoxemia

  28. Ventilation / Ventilation Control Tests • Occlusion Pressure (P100 or P0.1) • P100 is the pressure generated during the first 100 milliseconds of inspiratory effort against an occluded airway. • It is a measurement of the neural output from the medullary centers that drive ventilation rate and volume

  29. Ventilation / Ventilation Control Tests • Occlusion Pressure (P100 or P0.1) Normally P100 values are: • 1.5 – 5.0 cm H2O Usually measured at varying PetCO2 values or levels of O2 desaturation to assess the effect of changing stimuli to ventilation

  30. Ventilation / Ventilation Control Tests • Occlusion Pressure (P100 or P0.1) P100 is usually plotted against PetCO2

  31. Ventilation / Ventilation Control Tests • Occlusion Pressure (P100 or P0.1) • P100 values will normally increase with PaCO2 (hypercapnia) or PaO2 (hypoxemia) • Healthy patients typically increase occlusion pressure 0.5 to 0.6 cm H2O/mm Hg PCO2 • Patients with COPD will not increase the P100 when the PaCO2 in increased

More Related