1 / 21

SIS-100 simulation

SIS-100 simulation. Partha Pratim Bhaduri Subhasis Chattopadhyay VECC, Kolkata. p-A simulation for J/ y at SIS-100 Much geometry optimization for SIS-100. p-A simulation. Motivation.

holden
Download Presentation

SIS-100 simulation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIS-100 simulation Partha Pratim Bhaduri Subhasis Chattopadhyay VECC, Kolkata

  2. p-A simulation for J/y at SIS-100 Much geometry optimization for SIS-100

  3. p-A simulation

  4. Motivation • The aim of the relativistic heavy-ion collisions is to study the onset of de-confinement and the properties of the de-confined media in the laboratory. Hence it is necessary to define unambiguous and experimentally viable probes for de-confinement. • In this respect proton-nucleus (p+A) collisions must be a fundamental component of any heavy-ion physics program • Defines the reference baseline relative to which we recognize HI specific phenomena • p+A collisions provide a measure of the nuclear effects – helps in disentangling the “QGP” effect from the “non-QGP” effects. Here there is no formation time for the “secondary” medium , hence such collisions provide as essential tool to correctly account for the effect of the nuclear medium initially present. 4

  5. System • The specifications of the system chosen are: • Target : Au, Cu, S, O, C • Projectile : p (1, 1) • Beam energy : 30 GeV • Event generator used : HSD – 2.5 • Events : 5,000 (ISUBS = 50, NUM = 100) 5

  6. J/y pseudo-rapidity distribution pC pO pS pCu pAu pC pO pS pCu pAu CMS Frame Laboratory Frame Results with HSD 6

  7. pC pO pS pCu pAu J/y transverse momentum spectra 7

  8. HSD Pluto HSD vs. Pluto (muon pseudo-rapidity distribution) 8

  9. Laboratory Frame CMS Frame Muons decayed from J/y Isotropic decay in J/y rest frame Laboratory Frame 9

  10. CbmRoot Version: Trunk version Number of events : 4000 Much geometry : Standard Geometry • 2 layers in 5 stations • Distance between layers 10 cm. • Gap between absorbers 20 cm • 3 layers at the last trigger station • Total 13 layers • Total length of Much 350 cm Signal : J/ decayed muons from HSD for p+Au system for 30 GeV p beam Background : central UrQMD events for p+ Au at 30 GeV/n Much Hit producer w/o cluster & avalanche L1(STS) & Lit (Much) tracking with branching Absorber thickness (cm): 20 20 20 30 35 100 Simulation 10

  11. Analysis • Use the reconstructed data after the full tracking through the detector set-up. • Reconstructed global tracks have to satisfy : • Fraction of true hits (truehits/(true hits+ wrong hits+fake hits) >= 0.7 • No. of STS Hits associated with the global track >=4 • No. of Much Hits associated with the global track >=10 • Chi2 primary <=2 11

  12. Raw HSD Layer # 1 Layer # 3 Layer # 5 Layer # 7 Layer # 9 Layer # 11 Detector Acceptance 12

  13. Negligible background effect Invariant mass spectra Pure HSD Reconstruction efficiency : 25 % Embedded Reconstruction efficiency : 23.8 % 13

  14. Geometry optimization

  15. Our aim is to optimize the geometry of the muon set-up for SIS-100. • Optimization should be done with low mass vector mesons (lmvms) rather than J/ψ and at the lowest available energy. • J/ψ measurements due to low background after more than 2 m of Fe are not so sensitive to the muon setup as the measurements of muons from LMVM. • Issue is to reconstruct the soft muons ( eg: ω→μμ ) • We have chosen central Au+Au events at 8 AGeV together with ω→μμ. • Use the same set-up in simulation for J/ψ & LMVM. For LMVM use information from stations just before the last thick absorber. • Run full simulation & obtain signal reconstruction efficiency & S/B ratio. • Statistics : 10k central events 15

  16. We have to decide upon : • Total number of stations(layers) • Total absorber thickness, total no. of absorbers & the absorber material • Number of stations (2/3) in between two absorbers • Distance between stations & absorber to station distance • Present constraints in simulation : • Absorber material (Fe, Pb, W ) • Layer to layer distance >= 10 cm. • Absorber to layer distance >= 5cm.

  17. Absorber thickness (cm): 20 20 20 30 35100 • Cuts : • No. of Much hits>=9 • 70 % true hit • No. of STS Hits >=4 Number of stations : 13(2+2+2+2+2+3) Absorber to station distance : 5 cm. Layer to layer distance : 10 cm. Super event (SE) analysis for bkg. Gaussian fit to signal Polynomial fit to bkg. • Cuts : • No. of Much hits>=9 • 70 % true hit • No. of STS Hits >=4 Reconstruction efficiency : 0.5 % Estimated Signal : 645.234 Estimated Bkg. : 573.028 S/B : 1.126

  18. Option II : Reduced geometry • Cuts : • No. of Muchhits>=7 • 70 % true hit • No. of STS Hits >=4 Number of stations : 11(2+2+2+2+3) Absorber to station distance : 5 cm. Layer to layer distance : 15 cm. Super event (SE) analysis for bkg. Gaussian fit to signal Polynomial fit to bkg. Absorber thickness (cm): 20 20 30 35100 Reconstruction efficiency : 1.6 % Estimated Signal : 3997.52 Estimated Bkg. : 30052.1 S/B : 0.133 GEM Modules : 25.6 cm. * 25.6 cm. # of modules : 1928

  19. Option III : Reduced Geometry • Cuts : • No. of Muchhits>=7 • 70 % true hit • No. of STS Hits >=4 Number of stations : 9 (3+3+3) Absorber to station distance : 10 cm. Layer to layer distance : 10 cm. Super event (SE) analysis for bkg. Gaussian fit to signal Polynomial fit to bkg. Absorber thickness (cm): 30 70 125 Reconstruction efficiency : 1.4 % Estimated Signal : 2874.44 Estimated Bkg. : 9936 S/B : 0.2866 GEM Module : 25.6cm.*25.6 cm. # of Modules : 1512

  20. Comparison of different geometries

  21. To do list ….. • Continue the study with 9 station configuration but with same total absorber thickness (125 cm.) • Test the configuration for charmonia • Study of gaps ( station to station & station to absorber)

More Related