1 / 6

VACC - Volatility Aerosol Composition and Concentration

VACC - Volatility Aerosol Composition and Concentration. VACC – Science Summary. Is CN mixed into cloud from above and/or below? Out of cloud deep profiles Porpoise through area to look for variation in CN Characterise CN concentration and composion below and above cloud

holt
Download Presentation

VACC - Volatility Aerosol Composition and Concentration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VACC - Volatility Aerosol Composition and Concentration

  2. VACC – Science Summary • Is CN mixed into cloud from above and/or below? • Out of cloud deep profiles • Porpoise through area to look for variation in CN • Characterise CN concentration and composion below and above cloud • If isolated cloud available characterise CN concentration and composition of inflow and outflow • orbits at different levels or straight and level legs perpendicular to wind. (depends on the extent of the cloud)

  3. VACC – flight leg requirements • CPC – N (R > 5 nm) • 10 Hz data • flow controlled at 3 l/min all levels • No special flight requirements • SMPS – dN/dR (5 nm < R < ~200 nm) • Scan every 2.5 minutes • Sample flow controlled at 1 l/min all levels • Sheath flow controlled at 10 l/min all levels • Flight requirements: • Constant altitude for duration of scan • Preferably straight but can deal with wide angle turn/orbit • OPC – Volatility – constant temperature – dN/dR (50 nm < R < 1 µm) • 1 Hz data • Sample flow controlled at 0.12 l/min at all levels • No special flight requirements • OPC – Volatility – scanning temperature - dN/dR (50 nm < R < 1 µm) • Scan every 8 minutes • Sample flow controlled at 0.12 l/min at all levels • Flight requirements: • Constant altitude for duration of scan • Preferably straight but can deal with wide angle turn/orbit • Summary • Flight speed as slow as possible • Altitude profiles of CPC and OPC-volatility-set temperature obtainable • For SMPS or OPC-volatility – scanning temperature: require straight and level or level in slow turn flight legs. • Minimum operational pressure 500 mb ~6000m • Cannot operate in cloud

  4. B047 – 09:22 (UTC)

  5. 75°C 100°C Sample can be considered dry. MSA / Sulphuric acid 130°C 160°C Ammonium Hydrogen Sulphate 200°C 230°C Ammonium Nitrate 260°C 300°C Ammonium Sulphate Sodium Hydrogen Carbonate No particles R > 0.55μm

  6. External/Internal Mixing.

More Related