1 / 11

C T A Camera Development

Conceptual Mechanical Design. C T A Camera Development. Rich Northrop Laboratory for Astrophysics & Space Research University of Chicago. Consortium Meeting Chicago May 28 – June 1 2013. Vers3.

Download Presentation

C T A Camera Development

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Conceptual Mechanical Design C T A Camera Development Rich Northrop Laboratory for Astrophysics & Space Research University of Chicago Consortium Meeting Chicago May 28 – June 1 2013 Vers3 May 28 - June 1, 2013 R. Northrop

  2. Camera - Primary Geometry Total estimated weight – 646 kg (1424 lbs.) Bounding Diameter – 1.75 m (68.7”) Length - 0.91 m (36.0”) Inner structure/sensor modules – 357 kg Outer structure/adjust mech. - 289 kg Drawer Structure Inner Enclosure Setback Outer Enclosure Inner Enclosure Main Box Mount Flange Bulkhead CTA Meeting Chicago May 28 - June 1, 2013 R. Northrop

  3. Motherboard Cage FEE Bulkhead Post PreAmp Sensor Lattice Sensor/FEE/Cage/Drawer Structure (Present concept) Considering Heat pipe imbedded in Post May 28 - June 1, 2013 R. Northrop

  4. 52mm – 54mm – 56mm – 54mm – 56mmfront / 54mmback Pitch History Flip Concept Bulkhead/Sensor/FEE/Cage /Motherboard Interface Locating Pin – Inject/Eject May 28 - June 1, 2013 R. Northrop

  5. Camera Front Showing Fans ,Telescope mount Ring,& Power supplies Camera Back Showing Rolling rear door May 28 - June 1, 2013 R. Northrop

  6. Camera Mount Ring Propose 3 Point Mount Structure mount impact on Shutter Design May 28 - June 1, 2013 R. Northrop

  7. May 28 - June 1, 2013 R. Northrop

  8. Camera Adjustment Mechanisms X-Y-Z High load capacity – very accurate – very expensive UC Trice Primary mirror Z-stage adjustment + - .002 Standard X – y stages - many options May 28 - June 1, 2013 R. Northrop

  9. May 28 - June 1, 2013 R. Northrop

  10. .0002” under 25 lb. top load Low wall stress under estimated actual loading - need study with adjustment and mounting attachments .0017” under 300 lb. UDL Stress studies of selected structure components May 28 - June 1, 2013 R. Northrop

  11. Camera Assembly at University of Chicago Scheduled February 2014 May 28 - June 1, 2013 R. Northrop