Energypac offers dry type transformers encapsulated under Vacuum in epoxy resin. These technologically advanced transformers are environmentally friendly, maintenance-free, and manufactured to meet industry standards. With production capacity up to 3150 kVA, they cater to diverse applications including air terminals, refineries, power plants, and more. Energypac's CRT ensures high-performance and reliability, with certifications such as ISO 9001 and ISO 14001. Benefit from their competitive edges and cutting-edge production technologies from Europe. Save space and eliminate environmental risks with these self-extinguishing transformers, designed to withstand extreme conditions.
E N D
Crafted with pride First time ever in Bangladesh Cast Resin Transformers Engr. Saifur Rahman CRT
Product range, capacity and roadmap • Standard Technical features • Manufacturing process and machine visual • Environmental, Climatic and fire classes • Testing process and methods • Quality Control • Product standard accessories • References Contents: What is a dry type transformer General Application Energypac’s Competitive Edges Design, Machineries and origin Why Vacuum cast coil Benefits Environment friendly Energypac’s product competitive edges Comparison: Dry Transformers versus Oil Transformers Economical Aspects CRT
What is a dry type transformer: Energypac manufactures a transformer which does not use any kind of liquid for cooling, it has windings encapsulated under Vacuum, in epoxy resin reinforced with fibre glass mesh. It is the most technologically advanced design for extreme conditions. Energypac has flexibility to produce transformers for optimum space utilization, and special requirements. These transformers meet strict parameters with respect to electrical system demands, are virtually maintenance free and are manufactured in accordance with industry and international standards including, IEC 60076-11, ISO 9001 and ISO 14001. Energypac Cast Resin Transformers Production Range up to 3150 kVA and up to 22 kV CRT
Air ports • Refineries and petrochemicals • Chemical plants • Cement plants • Textile plants • Power plants • Metro railways • Steel Plants • Material handling equipments • Power station- Hydro, Thermal, Nuclear General Applications High Rise Buildings Hotels Hospitals Theatres and Multiplexes Radio and TV Towers Electronics Industries IT Parks Stadiums Off-Shore platforms/Oil Rigs Ships Windmills Ports CRT
Most advanced production technologies from Europe to guarantee the best product quality. • The most demanding quality control system to guarantee the total reliability of the product. • First time production for dry type transformers in Bangladesh. • The deepest experience in the design to guarantee the best technical solutions in all applications by European Consultant and experts. • Present all over Bangladesh and guarantee the faster delivery and best after sales service. • ISO 9001, ISO 14001 IEC 17025 certifications. Energypac’s Competitive Edges CRT
Standard designs: • High Voltage winding material: foil conductor displaced in many disks. • Low Voltage winding material: aluminum/copper foils. • Insulation class: F, H. • Machineries and Origin: • Core sharing machine, Japan • LV Winding machine- 1no, BF Electromechanical, Italy (160kVA and above) • HV Foil Winding machine- 1no, BF Electromechanical, Italy (250kVA and above) • HV Coil/wire winding machine- 1no, BF Electromechanical, Italy (100kVA-200kVA) • Vacuum casting machine- 1no, Hedrich, Germany Design, Machineries and origin • Raw materials and origin: • Aluminum Foil and wire - Hydro, Norway; • Resign, Hardener, Filler – Elantas Camattini, Italy; • Insulation Material – Haotai, P. R. China; CRT
Partial discharge free • State of the art casting technology. • Stronger resistance against short-circuit stress. • Superior behaviour on load changes (thermal). • Better performance under dynamic loads (mechanic). • Better performance under severe ambiental conditions (exceeding E2). • More suitability for extreme environmental conditions. Why Vacuum cast coil Vacuum cast coil transformers are according to International standards. CRT
Self-extinguishingmaterial. • Maintenance free. • Compact and Space can save up to 25% compare to oil type • More flexiblein use • No production loss or interruption due to maintenance. • Partial coil replacement available at site if required within short time. • Continuous same performance without loss. (Reference temperature for oil type is 750C and dry type is 1200C) • Easy installation (need just a direct contact protection barrier). • Enclosure available if required. • High resistance to short circuits. • High capacity to support overloads. • High performance in dealing with seismic phenomenon. • Capable of withstanding the most severe of rolling and vibrating conditions. Benefits • Compared with oil cooled transformers of the same specification CRT
Reduced environmental contamination. • Zero riskofleakage of flammable or contaminatingsubstances. • No pollution risks due to the absense of any cooling fluids • Environmentalsafein production. • Well suitedto damp and contaminated areas. • No firehazard. • Transformers are non flammableand self-extinguishing. • When disposing of the transformer, the cast resin is considered an inert material and both the secondary windings and the core can easily be recovered Environment friendly CRT
The lowest partial discharge value due to most advanced casting technology. • The typical partial discharges is below 5pC(maximum allowed 10pC). • Epoxy resin cast under vacuum avoids entry of moisture and protects against aggressive environments. • Unique coil finishing provides smooth surface eliminating dust accumulation. • Self-extinguishing in the event of fire or arcing and no gases released with potential danger. • Step lap core configuration granting lower values of no load losses, no load current and noise level. Energypac’s product competitive edges • Maintaining E2, C2 and F1 classes. • Local manufacturing and competitive price • Faster delivery and response time. • Available material and automatic inventory system • European consultant and experts. • Adopted European Technology • In house testing facilities • Stringent QC and maintenance, ISO 9001-2008 CRT
The best alternative due to: • Suitable to operate in humid or heavily polluted environments (E2). • Suitable for operation, transport and storage at ambient temperatures down to minus 25 ºC (C2). • Restricted flammability, self fire extinction (F1). • Emission of toxic substances and opacity of fumes is minimized (F1). • Partial discharges bellow 5 pc in average. • Withstand the same impulse test even for exposed situation are available source arrestors kit. • Have more ability to withstand thermal and dynamic short circuit effects. • Mechanically stronger, safer against vibrations, earthquakes, etc.. • No liquid, neither leaks and no risk of polluting spills. • Fire hazard • Safety for people and property • Respect for natural life Comparison: Dry Transformers versus Oil Transformers CRT
Compact Design • An average of 20 % less volume (more for big sizes) • 15 % lessweight (more for big sizes) • Wherever there are space limitations, cast resin transformers (due to their compact construction) can be installed inside of a building and consequently closer to the load • The result: savings in the cost of connection and reduced losses in the power supply Comparison: Dry Transformers versus Oil Transformers • Compared with oil cooled transformers of the same specification CRT
Evaluating criteria: Comparison: Dry Transformers versus Oil Transformers CRT
Less space needed. • Less civil work needed. • No special safety features required. (fire detection) • Maintenance free. • Longer transformer life due to low thermal and dialectic ageing. • Can be installed closer to the point of consumption reducing load cable losses. • Optimal design subject to constant improvements in design as new materials become available. • Produced in high throughput, specialised and efficient Energypac factories. • Very low operational cost. • Easy installation of indoor or outdoor. Economical Aspects CRT
From 100 kVA up to 3150 kVA • High voltage: up to 11 kV • Low voltage: up to 0.415 kV • Vector Group DYN11 • Various ratings are available in ready stock • Per month production capacity is 10-15 Transformer, target is to reach 25-30 Transformer production per month within this facilities. • The production capacity can be doubled by introduce additional 1 no. HV machine. Product range, capacity and roadmap CRT
Standards IEC EN 60076-11 • Rated power up to 3,150 kVA • Rated voltage up to 11 kV • Cooling AN, ANAF (up to +40%) • Protection degree IP00 up to IP23 • High voltage winding Encapsulated, Aluminum/Copper foil • Low voltage winding Pre-preg layer between turns, Aluminum/Copper full width • Temperature rise 100K • Ambient design From -250C up to 600C • Insulation system temperature 155 ºC (Class F) • Partial discharges < 10 pC • Classes E2, C2, F1 Standard Technical features CRT
In process test • Magnetic balance test • Continuity test • Routine test • Ratio test, Instrument Calibration from Cali-Labs, India. • Winding resistance • No Load losses, Vanguard Instrument, USA • Full load losses • Power frequency over voltage test, Phoenix Technology, USA • Induced over voltage test (DVDF) • Partial Discharge (Omicron Switzerland) • Temperature rise test Testing process and methods Testing method: IEC 60076-11, 60270-2001 Tested and certified by BUET CRT
On process HV and LV coil test • On process and finish product QC • Casting QC in the basis of failure by testing the specimen • Maintain process for casting material as per expiry date. • Visual check in all steps • Testing • ISO 9001-2008 and 14001 Quality Control CRT
Product standard accessories Temperature relay and PT 100 Fan Mounting Kits Heat shrink, insulation and aluminum bar Glass fiber mesh, DMD insulation and aluminum foil Wheel and Anti vibration pad CRT
More available accessories Electronic relay for temperature monitoring andprotection Source Arrestors CRT
Square pharmaceuticals • 5 nos. 2000kVA References • Silkways Group: • 1 no. 1500kVA • Gopalganj Stadium (PWD) • 1 no. 2000kVA • Bando Design Limited • 1 no. 200kVA CRT
Thank you CRT