SAR & HAC 규격동향

SAR & HAC 규격동향. Definition of SAR. SAR (Specific Absorption Rate) 송신기로부터 인체에 흡수되는 단위질량 당 전자파의 양을 에너지로 표시한 것 . 단위는 watts per kilogram (W/kg). ICNIRP Guidelines. 국제비전리방사보호위원회 (ICNIRP) 가 전자파 인체노출 한계에 대한 Guideline 을 제시 2 W/kg (10g). 2 W/kg (10g). 유럽 일본. SAR Limits.

hwakeland
Download Presentation

SAR & HAC 규격동향

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SAR & HAC 규격동향

  2. Definition of SAR • SAR (Specific Absorption Rate) 송신기로부터 인체에 흡수되는 단위질량 당 전자파의 양을 에너지로 표시한 것. • 단위는 watts per kilogram (W/kg).

  3. ICNIRP Guidelines • 국제비전리방사보호위원회(ICNIRP)가 전자파 인체노출 • 한계에 대한 Guideline을 제시 2 W/kg (10g)

  4. 2 W/kg (10g) 유럽 일본 SAR Limits • 유럽과 일본 등은 2 W/kg (10g) 의 기준을 따르지만 미국과 캐나다, 한국 등의 나라들은 1.6 W/kg (1g) 을 기준으로 함. 1.6 W/kg (1g) *더 엄격한 기준임 미국 한국

  5. CE SAR Criteria • Test Standard : EN50630 2001 • Test Method : EN50361 2001 • Test scope of SAR Evaluation • Only Portable Device, Not Mobile Device • Head SAR Measurement only • Output power is more than 20mW • In case of Mobile Device applying a far field RF • exposure calculation according to EN50385/ EN50383

  6. FCC SAR Criteria • Test Standard : 47CFR Part 2.1093 • Test Method : OET Bulletin 65, Supplement C(July 2001) • Test scope of SAR Evaluation • Transmitter use distance < 20cm from Body • Head and Body SAR Measurements • Use distance ≥ 20cm applying MPE calculation • SAR Evaluation Criteria 가 제품의 사양에 따라 • 다소 복잡함. • FCC에서는 KDB (Knowledge Data Base) 문서를 통해 • Handset과 laptop 등의 Multi-transmitter 적용방법을 • Issue함.

  7. Overview RF Exposure KDBs • KDB 447498Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies • General SAR thresholds and conditions • Simultaneous-Tx(동시전송) 을 하지 않는 devices • KDB 616217 or 648474에서 다루지 않는 Simultaneous-Tx(동시전송) 가능한 multi-Tx product 적용방법 • Laptops, tablets, body-worn, and hand-held devices 등 • KDB 616217SAR Evaluation Considerations for Laptop Computers with Antennas Built-in on Display Screens • 주파수, 출력, 안테나 거리에 따른 test reductions 정의 등. • KDB 648474 SAR Evaluation Considerations for Handsets with Multiple Transmitters and Antennas

  8. DASY4 SYSTEM in KTL

  9. HAC (Hearing Aid Compatibility) ? • 보청기사용자들은 무선전화기를 사용할 때 RF field 에 의한 Interference 등으로 불편을 호소 • HAC는 무선기기와 보청기간의 호환성을 시험

  10. Backgrounds • 미국인구의 약 10%가 청력에 문제가 있으며 그 중 약 80% 가 보청기를 사용함 • 전세계적으로 약 5억 명이 청력장애를 앓고 있음 • 2003년 7월 FCC는 무선기기 제조사와 사업자에게 보청기 와 호환성을 갖는 단말기를 소비자에 공급하게 하는 rule을 채택

  11. ANCI C63.19 • 1996년 ANSI C63은 SC8 (medical devices) 아래 Task Group을 결성함 • ANSI C63.19-2001 의 Standard가 완성되어 현재 2007 Version까지 발행 • 800 ~ 3000 MHz 범위의 무선단말기와 보청기에 적용 되는 기준 • 무선단말기의 RF-Emission, T-coil mode와 보청기의 RF Immunity 시험에 적용

  12. ANCI C63.19 2007 • 2007 Version 주요 변경사항 • 2006, 2007 Version 을 2009년 까지 모두 적용이 가능 • 2010년부터는 2007 Version만을 적용해야 함.

  13. Operation of Wireless Device and Hearing Aid

  14. Organization and use of ANSI C63.19

  15. RF Emissions Test • RF E-field Emission, RF H-field EmissionMeasurement

  16. RF E & H field Emission Measurement of WD • The Grid is 5X5 area that is divided into 9 evenly • sized blocks or sub-grids. Example E-field Scan

  17. RF E & H field Emission Measurement of WD • M-Rating Determination Multiply the peak emissions values by an appropriate probe modulation factor. For GSM signal, Crest Factor = 26frames X 8times-slots =8.3 25frames used For ideal) Probe Modulation Factor =√ Crest Factor = 2.88 Peak Field Intensity = 20 · log ( Raw X PMF)

  18. RF E & H field Emission Measurement of WD • M Rating Determination : M3, M4 가 PASS Articulation Weighting Factor (AWF) • AWF shall be used for the • standard transmission protocols

  19. T-coil signal Test • Three quantities are measured and evaluated. • 1.Field intensity of desired signal at the center of the audio band. • 2.Frequency response of the desired signal measured • across the audio band. • 3.Signal quality, which is defined as the difference between • the desired and undesired magnetic field levels.

  20. T-coil Measurement setup in call mode

  21. AM 1D Probe AMCC AMMI WD PC Base Station Simulator T-coil Measurement setup in call mode

  22. T-coil Performance • Axial and Radial Field Intensity All Orientations of the magnetic field, in the axial, horizontal and Vertical position along the measurement plane Shall be ≥ -18 dB (A/m) at 1KHz, in 1/3 octave band filter. • Frequency Response • Signal quality

  23. T-coil Performance • Frequency response Magnetic field frequency response for WDs with a field between ≤ -15dB (A/m) at 1 kHz

  24. T-coil Performance • Frequency response Magnetic field frequency response for WDs with a field that exceeds -15dB (A/m) at 1 kHz

  25. T-coil Performance • Signal quality

  26. Hearing Aid compatibility • System performance classification table

  27. FCC Requirement for Manufacturers & Service providers • 2008년 Manufacturer requirements M3 이상의 레벨을 최소 1/3 이상의 모델에 적용 T3 이상의 레벨을 최소 두 모델 이상의 단말기에 적용 2009년 2월부터 50%의 모델에 M3이상을 요구하며 매년 기준을 강화 • 2008년 Service provider requirements M3 이상의 레벨을 최소 50% 또는 8대 이상의 단말기에 적용 T3 이상의 레벨을 최소 1/3 이상의 모델에 적용 2009년 2월부터 매년 기준을 강화 • 각 통신방식(CDMA, GSM) 에 따로 적용함

  28. Definition of a Model • No differences in form, features, or user capabilities, or that only differentiate particular carrier ► Not counted as distinct models • Change in the hearing aid compatibility rating ► give a new model name/number • Change in M or T rating ► “form, features of capabilities.” in change

  29. Bands and Modes without Standards • 2007 ANSI C63.19 establishes standards only for certain air interfaces in the 800-950 MHz and 1.6-2.5 GHz bands • Testing cannot be performed, and no rules currently apply, outside these bands/interfaces • FCC adopted streamlined process for adopting future expansions of Standard

  30. Multi-Band/Multi-Mode Phones • handsets must meet standards in all frequency bands, all air interfaces. Technical standards exists • No multi-band/multi-mode phones without standards currently exist. Except for Wi-Fi • Multi-band/multi-mode phones with Wi-Fi voice capability ► Be counted as Hearing aid-compatible under FCC rules ► Labeling must disclose that handset is not rated for Wi-Fi operation • ANSI ASC C63 consider new technologies & deciding what rules to establish going forward