Experimental study on flexible concrete by using polyurethane fiber

In this paper the properties of conventional concrete have been developed. Conventional concrete has the property of high brittleness and less flexural strength. This is a undesirable characteristics is mother of development of Flexible concrete to improve this deficiency. The Polyurethane fiber has the ability to impart considerably flexibility in concrete. For this purpose concrete cube, cylinders and beams experimentally tested. By the mixture of traditional concrete ingredients and special polyurethane fibers addition with water super plasticizers for good workability purpose. The test results have proved to be increased flexibility of the concrete. Dinesh W. Gawatre | Ajay G. Gaund | Dipali S. Dhondge | Amol U. Gandhale | Shubham Fartade "Experimental study on flexible concrete by using polyurethane fiber" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-4 , June 2018, URL: https://www.ijtsrd.com/papers/ijtsrd14158.pdf Paper URL: http://www.ijtsrd.com/engineering/civil-engineering/14158/experimental-study-on-flexible-concrete-by-using-polyurethane-fiber/dinesh-w-gawatre<br>

ijtsrd
Download Presentation

Experimental study on flexible concrete by using polyurethane fiber

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. International Research Research and Development (IJTSRD) International Open Access Journal flexible concrete by using polyurethane International Journal of Trend in Scientific Scientific (IJTSRD) International Open Access Journal ISSN No: 2456 ISSN No: 2456 - 6470 | www.ijtsrd.com | Volume 6470 | www.ijtsrd.com | Volume - 2 | Issue – 4 Experimental study on f olyurethane fiber Dinesh W. Gawatre1, Ajay G. Gaund , Ajay G. Gaund2, Dipali S. Dhondge2, Amol U. Gandhale2, Shubham Fartade of Civil Engineering, SAOE, Kondhwa (bk), Pune f Civil Engineering, SAOE, Kondhwa (bk), Pune, Maharashtra, India , Shubham Fartade2 1Assistant Professor, Department of Civil Engineering, SAOE, Kondhwa (bk), Pune 2Student, Department of Civil Engineering, SAOE, Kondhwa (bk), Pune ABSTRACT In this paper the properties of conventional concrete have been developed. Conventional concrete has the property of high brittleness and less flexural strength. This is a undesirable characteristics is mother of development of Flexible concrete to improve this deficiency. The Polyurethane fiber has the ability to impart considerably flexibility in concrete. For this purpose concrete cube, cylinders and beams experimentally tested. By the mixture of traditional concrete ingredients and special polyurethane fibers addition with water super plasticizers for good workability purpose. The test results have proved to be increased flexibility of the concrete. of Civil Engineering, SAOE, Kondhwa (bk), Pune, Maharashtra, India , Maharashtra, India conventional concrete develops crack at, due to shrinkage , tensile stress and creep.CC is very rigid strain of about 0.1%. that CC highly brittle and hard. It structure causes failure under strain due to deficiency in flexibility . To overcome this deficiency Flexible Concrete is eveloped. Which is prepared by mixing polyurethane with proper mix design. This hane is able to develops required flexibility. Flexible concrete is mixture of the same materials we Additionally with Polyurethane fiber and Water Reducing and to improve lexible concrete uses less amounts of fiber generally up to 2% by volume of aggregates. At the beam can deflect well without direct failure. The various ingredients of Flexible Concrete work together to share the applied load. Flexible concrete has proved to be more in flexural strength than Conventional concrete. It has good energy absorbing property which makes FC suitable for seismic prone area Conventional concrete suffers hen stressed or strained in an heavy load, creep load or an earthquake and that of Flexible concrete remain safe to use at tensile strain up to 150% of conventional concretes. While selecting polyurethane fiber for flexible concrete. It was found that PU fiber was of low cost and high performance. This fiber has high bonding property with cementitious material. It has high abrasive nature, zero water absorption, highly elastic property. This fiber is widely used in civil engineering constructions such as pavements, building members in seismic conventional concrete develops crack at, due to shrinkage , tensile stress and creep.CC is very rigid and has much lower in strain of about 0.1%. that makes CC highly brittle and hard. It structure causes failure under strain due to deficiency in flexibility . To overcome this deficiency Flexible Concrete is developed. Which is prepared by mixing fiber in CC with proper mix design. T Polyurethane is able to develops required flexibility. Flexible concrete is mixture of the same materials we used for CC, Additionally with Polyurethane fiber and super plasticizer for Water Reducing and workability. Flexible concrete uses less amount fiber generally up to 2% by volume of flexural stress the beam can deflect well with direct failure. The various Concrete work together to share the applied load. Flexible concrete has proved to be more in fle strength than Conventional concrete. It has good energy absorbing property which makes FC suitable for seismic prone area Conventional concrete suffers direct failure. When stressed or strained in an heavy load, creep load or an earthquake and that o concrete remain safe to use at tensile strain up to 150% of conventional concretes. While selecting polyurethane fiber for flexible concrete. It was found that PU fiber was of low cost and high performance. This fiber has high bonding property w cementitious material. It has high abrasive nature, zero water absorption, highly elastic property. This fiber is widely used in civil engineering constructions such as pavements, building members in seismic prone area. properties of conventional concrete have been developed. Conventional concrete has the property of high brittleness and less flexural strength. This is a undesirable characteristics is mother of development of Flexible concrete to improve this The Polyurethane fiber has the ability to impart considerably flexibility in concrete. For this purpose concrete cube, cylinders and beams experimentally tested. By the mixture of traditional concrete ingredients and special polyurethane fibers plasticizers for good workability purpose. The test results have proved to Keywords: Flexural strength, split tensile strength, compressive strength, Polyurethane fiber ve strength, Polyurethane fiber : Flexural strength, split tensile strength, INTRODUCTION Concrete is a mixture of cement, coarse and that sets after mixing with water in proportion at certain chemical reaction. In old days concretes were lime-based concretes in which binding material was lime. After some cement concrete, hydraulic cements, were used Before cement concrete road, asphalt concrete for pavement surfaces, where bitumen is used as cementitious material. Concrete is much strong in compressive strength, but much lower in strength. To improve tensile strength it is reinforced with steel that are strong in tension. The elasticity of conventional concrete is generally constant at low stress levels but as the stress level increases it starts decreasing as micro cracking develop. It is much weak in coefficient of thermal expansio stress increases it shrinks. The structures made from stress increases it shrinks. The structures made from , coarse aggregates that sets after mixing with water in proportion at certain chemical reaction. In old days concretes were based concretes in which binding material was . After some development development Portland , were used. , asphalt concrete is used where bitumen is used as Concrete is much strong compressive strength, but much lower in tensile strength it is reinforced The elasticity of concrete is generally constant at low the stress level increases it starts as micro cracking develop. It is much cient of thermal expansion and as the @ IJTSRD | Available Online @ www.ijtsrd.com @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun Jun 2018 Page: 744

  2. International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470 result in polycarboxylates based super plasticizer mix than sulphonated melamine formaldehyde based super plasticizer . OBJECTIVES: The main purpose is to increase the flexural strength of the concrete. S.Uttamraj, examined that Results between comparison of conventional concrete with fly ash of 30% and ECC made with PVA fiber with 30% of fly ash. Due to fly ash The conventional concrete shows reduce workability. But it is improved by adding super plasticizer. This paper showed that there was significant increase in flexural strength with increase in fiber content. The compressive strength is more in less percent of fiber used. But split tensile strength and flexural strength was 49%increased and was 48 % increased as compared to conventional concrete. K.Ashwanath, Dr.Md.Rafeeq has To make concrete flexible and self-healing. To improve tensile behavior of concrete To increase strain capacity and increase elasticity. To improve the quality of the rigid pavement. To improve split tensile strength. APPLICABILITY OF THE F.C.: In seismic resisting structure , high ductility in the flexible concrete can difference in a seismic structure. make a noticeable U. L. Deshpande1, Pranesh B Murnal2According to test results, the member is withstanding with heavy load and a large deformation without failure to the brittle fracture , even steel reinforcement were not used. Conventional concrete has brittle behavior where ECC has ductile nature. Flexural strength of ECC is 60% more than conventional concrete, with nearly same compressive strength of ECC and conventional concrete. Split tensile strength of ECC is 32% more than CC. The cost of ECC is about two to three times that of CC. The advantages of ECC is more compared with conventional concrete. As the use of fly ash gives less environmental impact because disposal of fly ash is serious issue, hence Eco Friendly. In the road construction work it is applicable as pavement having crack resisting property having high flexural strength for long durability. For good aesthetic architectural design. METHODOLOGY: 1.The materials essential for the project work are to be procured of predetermined grade and quality. This research is having requirement of materials. Cement, Sand Aggregate, Polyurethane Fig. Flexible concrete LITERATURE REVIEW: 2.Basic property tests on cement ( Standard consistency test, Setting time test, Fineness test, Compressive test ), sand (specific gravity test, Fineness test) and coarse aggregate (specific gravity test , flakiness and Elongation test, Fineness test ) are conducted properly. Sagar Gadhiya , T N Patel and Dinesh Shah has examined that compressive strength is directly related to the flexural strength and inversely related to the deflection but if the compressive strength is kept in limited ranges, the desirable value of related parameter can be obtained. As Compared to conventional mix the adjusting mix gives more ultimate tensile strength of ECC. As the fiber size is increased the compressive strength and stiffness decreases. If the fibers are kept perpendicular to the shear plane Then ductility in direct shear significantly improved when the fibers are perpendicular to the shear plane. The workability of concrete gives higher 3.Prepared Mix design for M30 grade concrete. 4.Take PU fiber of required size and shape in various percentage (0.1%, 0.2%, 0.3%, 0.4%) of coarse aggregate. @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun 2018 Page: 745

  3. International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470 5.Preparation of standard cube (150mm x150mm x 150mm ), cylinders (d=300mm, dia. =150mm), beam ( 150mm x 700mm x150mm) of varying percentage of fiber. 3 items of each , including conventional concrete. Graphical representation of test results: 600 Conventional Concrete Split Tensile Strength (psi) 500 6.Test these specimens on the CTM, UTM and take the mean of 3 results of same kind for accuracy. 0.1% PU 400 300 0.2% PU" 7.These results of Flexible Concrete compare e with Conventional Concrete and represented in graphically manner. 200 0.3% PU" 100 TESTING AND RESULTS:- 0.4% PU" 0 1 COMPRESSIVE TEST: Graph 2: comparison between split tensile strength of C.C.&F.C. The compressive strength test is carried out in order to prove that the compressive strength of bendable is not significantly more the FRC but the compressive strain in bendable concrete is about 50 – 70% more than that of normal & FRCs. Defined as compressive strength of concrete specimen after 7 days, 14 days and 28 days of curing. Compressive strength= force / area . FLEXURAL STRENGTH TEST:- This test is carried to check the deflection & self- healing property of the flexible concrete. And to determine nature of flexible concrete under the flexural stresses. that is the strength of a member to resist failure in bending. this test is carried out by measuring loading on unreinforced 150x150x700 mm concrete beams. The flexural strength is in general called as “ Modulus of Rupture” (MR) in MPa. The relation between material and its MR. 60 Compressive Strength N/mm^2 50 Coventional Concrete 40 0.1% PU Fiber 30 0.2% PU Fiber Modulus of Rupture=3PL/2bd^2 20 10 0.3% PU Fiber Graphical representation of test results: 0 0.4% PU Fiber 7 14 28 12 Conventional Concrete 11 Compressive strength at Days 10 Flexural Strength N/mm^2 9 0.1%PU Graph 1: Comparison of Compressive strength in between CC and F.C. 8 7 6 0.2%PU 5 SPLIT TENSILE STRENGTH: 4 0.3%PU 3 The tensile strength of concrete is measured in three ways: direct tension, splitting tension, and flexural. It is difficult to test concrete in direct (uniaxial) tension because of the problem of gripping the specimen satisfactorily and because there must be no eccentricity of the applied load. Therefore, direct tensile test is not standardized and rarely used. Modulus of rupture test and splitting test are commonly used to determine the tensile strength of concrete.Fct=2P/pi.l.d 2 1 0.4%PU 0 1 Graph3: comparison of flexural strength in between C.C. and F.C. CONCLUSION: 1.From the analyzed data and the results it proves that the strength of Flexible Concrete is increasing @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun 2018 Page: 746

  4. International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470 3.Sagar Gadhiya1 Prof. T. N. Patel2 Dr. Dinesh Shah3. 1PG Professor1,2Department of Civil Engineering Department of Architecture 1,2,3Sardar Vallabhbhai Institute of Technology (Vasad),Gujarat Technological University. Parametric Study on Flexural Strength of ECC. as the percentage of PU fiber accordingly increased. As the mix design, environmental condition, temperature and all other parameters were kept same as that of conventional concrete. There is just a variation of percentage of PU fiber used in concrete. The Flexible Concrete gives more Compressive strength , Flexural strength and Split Tensile strength as per Graph no:1, Graph no:2, Graph no:3. Student 2,3Assistnat Engineering 4.Satheesh v s1, Yuvaraja n2, Vinoth v2, Balaji p2, Abhinav Gurung2. 1.Adhiyamaan college of engineering, assistant professor, hosur, India2. Adhiyamaan college of engineering, hosur, India. Experimental Study on Flexural Behavior of Bendable Concrete. 2.In this project the compression and flexural strength of concrete conventional concrete are increased. Therefore it is proved that the bendable concrete is more strength than the conventional concrete and it is more flexible so that it resists cracks and acts as self healing and gives more efficiency in seismic regions. are compared with 5.K.Selvakumar1, A.Deivasigamani3, Ms.S.Amutha4 Student, Civil, Sri Muthukumaran Institute of technology, Chennai, India1 Student, Civil, Sri Muthukumaran Institute of technology, Chennai, India. 2 Student, Civil, Sri Muthukumaran Institute of technology, Chennai, India. 3 Assistant Professor, Civil, Sri Muthukumaran Institute of technology, Chennai, India4. Experimental study on bendable concrete. R.Kishore kumar2, 3.It is much tougher and has good compressive strength for 7 days, 14 days and 28 days and The split tensile strength of the FC concrete is much better when compared to the conventional concrete. 4.It was observed that by physical appearance on PU-FC specimen has greater crack control as can be seen on surface reduction of crack widths and crack spacing. For conventional concrete it was observed that micro cracks and surface crack were more when compared to FC. 6.Dr. A. W. Dhawale1, Mrs. V. P. Joshi21Associate Professor & PG Coordinator, Imperial College of Engineering & Pune.2Assistant Professor Paravatibai Genba Moze College of Engineering,, Pune. Engineered Cementitious Composites Applications. Research Wagholi, for Structural 5.The study of this paper shows that as the fiber content is increases in the members the flexural strength increases. REFERENCE: 1.S.Uttamraj1, K. Ashwanth2, Dr. Md.Rafeeq3 1(Research scholar, JNTUH/, INDIA) 2(civil dept, AURORA, Bandlaguda, INDIA) 3(Research Officer TSERL Himayat Sagar INDIA) An comparative study on Conventional concrete and Engineered Cementitious PVA)- REVIEW Composites(ECC- 2.U.L. Government College of Engineering, Karad- 415124, India. Government Engineering, Aurangabad, India Ductile Concrete Using Engineered Cementitious Composites. Deshpande1, Pranesh B Murnal2. College of @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun 2018 Page: 747

More Related