Alkaline Methanol Fuel Cell. Tam Duong Dr. Yushan Yan. Fuel Cell. Electrochemical device Convert chemical energy into electricity Having two electrodes: Positive (cathode) and Negative (anode) Reaction with the presence of electrolyte. Working depends on the catalyst. System.
E N D
Alkaline Methanol Fuel Cell Tam Duong Dr. Yushan Yan
Fuel Cell • Electrochemical device • Convert chemical energy into electricity • Having two electrodes: Positive (cathode) and Negative (anode) • Reaction with the presence of electrolyte. • Working depends on the catalyst
System Cell system with rotating disk, reference electrode, platinum wire, and gas vent.
Why Methanol Fuel Cell? • Methanol has high energy density. • Easy to store in liquid state in room temperature. • Fuel cell works as a battery that doesn’t go down or need to be charged. • Highly promising to serve as a power source for cell phones, and laptops. • Reduce the pollution
Current Methanol Fuel Cell • Alkaline Methanol Fuel Cell: Hydroxide flow from cathode to anode. • Waste Products: Water and Carbon Dioxide • Toxic and flammable • In 2005, ICAO (International Civil Avitation Organization) DGP (Dangerous Food Panel) voted to allow passengers to carry and uses micro fuel cell when travelling aboard.
Basic Information • Nafion membrane (ionomer) • Qualified Power (W): 100 kW to 1MW • Working temperature: 90 – 120 deg C • Electrical efficiency: -Cell : 20-30% -System: 10-20% • Typical fuel cell: 0.6 – 0.7 V
Method of Collecting Data • Coating the glassy carbon electrode with the calculated volume of catalyst • Sample Volume = (Electrode Area)*(Loading/Area)*(Solution Concentration) • 10 ul of .05% Nafion • Making 250 mL electrolyte (0.1M KOH) • Setting the cell up with Pt wire and the reference electrode • Connecting the gas vent • Blowing gas into the cell and record data
mA Cyclic Voltammetry Oxidation V • One type of potential electrochemical measurement. (Potential scanning) • Forward sweep: reversible oxidation • Reversed sweep: Reduction • Used to calculate the surface area Reduction Basic Shape of a CV curve
Calculating the Theoretical Surface Area Calculating Experimental Surface Area Area (CV graph) [mA.V] x speed [1/V] x ratio [mC/mA] Constant [mC/cm2] x loading [µg/cm2] x area (electrode) [cm2] x 0.77
ETEK with Nafion (ORR) ORR curve without methanol at 5 mV/s scanning speed ORR curve with methanol at 5 mV/s scanning speed
ETEK with Nafion (HOR and MOR) MOR curve at 50 mV/s scanning speed HOR curve with 300 rpm at 5 mV/s scanning speed
SeNW (HOR and MOR) HOR curve with 300 rpm at 5 mV/s scanning speed MOR curve at 50 mV/s scanning speed
Gold NanoTube (HOR and MOR) HOR with 300 rpm at 5 mV/s MOR at 50 mV/s
Palladium Nanotube Chronoamperometry at -0.15 V vs Hg/HgO ORR with 1600 rpm at 5 mV/s
Palladium Nanotube (HOR and MOR) MOR at 50 mV/s HOR with 300 rpm at 5 mV/s
Silver Nanowire (100 µg) ORR with 1600 rpm at 5 mV/s HOR with 300 rpm at 5 mV/s
Silver Nanowire 50ug (HOR and MOR) MOR at 50 mV/s HOR with 300 rpm at 5 mV/s
Palladium and Platinum ORR with 1600 rpm at 5 mV/s Chronoamperometry at -0.15 V vs Hg/HgO
Palladium/Platinum (HOR and MOR) MOR at 50 mV/s HOR with 300 rpm at 5 mV/s
Ag/C (ORR) ORR_Ag/C (50 ug/cm2) ORR_Ag/C (100 ug/cm2)
Conclusion • Platinum nanotube, palladium nanotube work for HOR, MOR, and ORR. • Silver on carbon, silver nanowires, gold nanotube, selenium nanowires work for ORR even with methanol. Future Work • Testing platinum/silver alloy • Making silver nanowires