New Ideas in Specification Drainage & Specialties Products Hepworth – Doha, Qatar - Jan-14, 2012

New Ideas in Specification Drainage & Specialties Products Hepworth – Doha, Qatar - Jan-14, 2012. MIFAB - USA Manufacturer. Manufacturing facilities in Chicago, USA and around the world. All products tested and certified to USA ASTM and ASME Standards.

iria
Download Presentation

New Ideas in Specification Drainage & Specialties Products Hepworth – Doha, Qatar - Jan-14, 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Ideas in Specification Drainage & Specialties Products Hepworth – Doha, Qatar - Jan-14, 2012

  2. MIFAB - USA Manufacturer Manufacturing facilities in Chicago, USA and around the world. All products tested and certified to USA ASTM and ASME Standards. Michael Whiteside, owner. President of P.D.I. (Plumbing and Drainage Institute) in the USA. Represented by Hepworth, Doha - Qatar

  3. PRODUCTS • Floor, Area and Trench Drains • Stainless Steel Sanitary Drains • Roof Drains and Rainwater Shoes • Floor and Wall Cleanouts • Grease and Oil interceptors • Trap Seal Primers • Wall and Ground Hydrants • Access Doors • No Hub Couplings • BEECO Backflow Preventers • C-PORT pipe supports and Pipe Markers

  4. Innovations in Design A1 Body – Floor, area and roof drains, cleanouts. • A2 Body – Large area drains, floor drains, large diameter roof drains, and parking drains. More flexibility for the contractor in the field. • Reduces waste at the end of the job.

  5. Innovations in Design • Thread the strainer directly into the body. • No need for a membrane clamp in slab on grade installations.

  6. Stainless Steel strainers for the same price as Nickel Bronze ! • Strainer won’t “dish” or “cup”. Foot friendly. • Won’t discolor or tarnish. More Sanitary.

  7. Innovations in Design MIFAB Area Drains are always Adjustable * Adjustable to meet the finished floor. * Ductile iron grates Standard for “Special Duty” Load Rating.

  8. ProFormer - Trench Drains • Made from Polypropylene. • Acid and chemical resistant.

  9. ProFormer Stainless Drains • Heavy Duty, 14 Gauge S.S. • Designed for food areas. • Standard Type 304 stainless and available in Type 316 stainless. • Available in a wide variety of sizes and styles of drains.

  10. Roof Drains

  11. Roof Drain Dome Comparison • Zurn Z-100 Dome • - 4.5” high • - Free Area: 92 Sq. In. • Smith 1010 Dome • - 4.75” high • Free Area: 103 Sq. In. • MIFAB R1200 Dome • - 7 ½” high • - Free Area: 125 Sq. In.

  12. Water has to travel more distance around wide sump before draining. Narrower sump means less lateral velocity to overcome. Head pressure is greater – resulting in faster drainage. Roof Drains – Flow Design

  13. Cleanouts

  14. Grease and Oil Interceptors

  15. Grease and Oil Interceptors

  16. Grease and Oil Interceptors • MI-G Series - Grease Interceptors • 10 gauge steel, powder epoxy coated. • Center securing bolt • Legs on bottom to elevate unit from wet floor. • Available in “XL” Series for larger capacities, “L” series for low rough-in heights, “SD” & “SDH” Semi-Automatic units. The MI-G series has many accessories available such as: extensions (integral or bolt-on), Anode Packs, Anchor Flange and X-Heavy Lids.

  17. Oil Interceptors • MI-O Series: 10 gauge steel with baked-on epoxy finish. Center securing bolt. Heavy Gauge diamond plate steel cover. Two (2) side vent connections. • MI-O-HU Series: Same great features as above but with integral oil storage tank!!! • MI-OS Series: Oil/Sediment Interceptor with Heavy-Duty Grate and removable Sediment/Mud Pan.

  18. Trap Seal Primers Why Use Them? Prevent foul odors from entering the room via dry floor drain traps.

  19. WATER HAMMER ARRESTORS

  20. Access Doors – Styles & Types

  21. No Hub Couplings No Hub Couplings Regular Shielded No Hub Couplings 60 inch torque – 4.3 psi max line pressure with 10’ head Heavy Duty Shielded No Hub Couplings 100 inch torque–15 psi max line pressure

  22. Thank You!