An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prevention of anterior capsule contraction by anterior relaxing incisions with Nd:YAG laser Ken Hayashi, MD Motoaki Yoshida, MD Hideyuki Hayashi, MD Hayashi Eye Hospital, Fukuoka, Japan Authors have no financial interest in any materials described in this poster.

  2. Purpose Since contrast sensitivity is deteriorated significantly in proportion to the area of anterior capsule opening, surgeons should attempt to prevent severe anterior capsule contraction. The purpose of this study was to examine the effect of two or three Nd:YAG laser relaxing incisions made in the anterior capsular rim on prevention of anterior capsule contraction after cataract surgery.

  3. Methods Patients 100 patients scheduled for bilateral cataract surgery randomized to one of two groups a) Two or three relaxing incisions in the left eye at 3 days after surgery, and no incision in the right eye b) Performed oppositely Outcome measures 1) Area of the anterior capsule opening (mm2) 2) Percentage reduction of the opening area (%) 3) Visual acuity and refractive status 4) IOL decentration (mm) and tilt (°) 5) Degree of posterior capsule opacification (PCO) At 3 days, and 1, 3, and 6 months after capsulotomy

  4. Comparison of IOL decentration and tilt between the relaxing incisions and no incision groups Decentration (mm) 6 months Tilt (°) 6 months Decentration (mm) 6 months Tilt (°) 6 months Two incisions group 0.27 ± 0.33 1.22 ± 0.77 Three incisions Group 0.24 ± 0.14 1.25 ± 0.57 No incision group 0.21 ± 0.17 1.21 ± 0.75 No incision group 0.23 ± 0.13 1.40 ± 0.62 P value 0.3303* 0.7573* P value 0.7438* 0.7573 *No significant difference.

  5. Comparison of mean PCO value measured using Scheimpflug system between the relaxing incisions and no incision groups 1 month 6 months 1 month 6 months Two incisions group 8.8 ± 3.6 8.8 ± 3.4 Three incisions group 8.6 ± 4.5 7.5 ± 3.9 No incision group 8.8 ± 4.6 8.8 ± 3.8 No incisiongroup 8.5 ± 3.8 7.0 ± 3.2 P value 0.8312* 0.7546* P value 0.9208* 0.8091* *No significant difference.

  6. Conclusions 1) Three Nd:YAG laser relaxing incisions made in the anterior capsule decrease the anterior capsule contraction, whereas two relaxing incisions do not. 2) Degree of IOL decentration and tilt, or PCO does not worsen after Nd:YAG laser relaxing incisions.