HE- RBXs TESTS b.c. time and now!! Pelin Kurt, Irina Shreyber, Vitali Simirnov CERN/Unv.of Cukurova HCAL weekly meeting 16 Aug, 2005. Outline. Motivation Comparison of the Burn- in LED (Led Emitting Diode) runs with HEM runs Comparison of the Burn-in PED (pedestal) runs with HEM runs
E N D
HE- RBXs TESTS b.c. time and now!! Pelin Kurt, Irina Shreyber, Vitali Simirnov CERN/Unv.of Cukurova HCAL weekly meeting 16 Aug, 2005
Outline • Motivation • Comparison of the Burn- in LED (Led Emitting Diode) runs with HEM runs • Comparison of the Burn-in PED (pedestal) runs with HEM runs • Conclusion
Motivation • HE- has 18 sectors • Each sectors have only one RBX (Readout Box) which has 4 Readout Module (RM) and one Calibratoin unit • Each RM has two connectors • These connectors has totally 24 channels. Six of these channels are empty
Motivation • RBXs were tested before and after installation on wedges. The goal of the test is to check its functionality.. • Calibration of each RM were done in the fallowing ways -- by using 1.5 mCi radioactive Cobalt 6o source which was sent over the surface of the scintillator. It enables a comparison of the results with the data obtained previously with the same or another Cobalt source. --- RBXes on all sectors have been tested for Pedestal patterns in Normal and Histogramming mode. we have also tested all RBXes using LED signals.
Comparison of led runs(sect1_RM1) Burn–in HEM
Comparison of led runs(sect4_RM1) Thesignals which are in the blue circles come from the same cable
Comparison of led runs(sect10_RM2) Thesignals which are in the blue circles come from the same cable
Ledb/Ledh results Sector 15-16-17 has some problem, we still check it
Comparison of pedestal runs(sect16_RM4) Thesignals which are in the blue circles come from the same cable
Conclusion • There are some big Rms values on LED results. So the LED must be normalized on PIN diode Response. But I have not done it yet, I am working about it. I need to check it again after normalization. After then we can reach the exact results of this test. • On PED, the sesults are much better then LED as expected. • Histogram comparison could not have been done since some problems on the HistCompareHEM.C script.