An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HE- RBXs TESTS b.c. time and now!! Pelin Kurt, Irina Shreyber, Vitali Simirnov CERN/Unv.of Cukurova HCAL weekly meeting 16 Aug, 2005

  2. Outline • Motivation • Comparison of the Burn- in LED (Led Emitting Diode) runs with HEM runs • Comparison of the Burn-in PED (pedestal) runs with HEM runs • Conclusion

  3. Motivation • HE- has 18 sectors • Each sectors have only one RBX (Readout Box) which has 4 Readout Module (RM) and one Calibratoin unit • Each RM has two connectors • These connectors has totally 24 channels. Six of these channels are empty

  4. Motivation • RBXs were tested before and after installation on wedges. The goal of the test is to check its functionality.. • Calibration of each RM were done in the fallowing ways -- by using 1.5 mCi radioactive Cobalt 6o source which was sent over the surface of the scintillator. It enables a comparison of the results with the data obtained previously with the same or another Cobalt source. --- RBXes on all sectors have been tested for Pedestal patterns in Normal and Histogramming mode. we have also tested all RBXes using LED signals.

  5. Comparison of led runs(sect1_RM1) Burn–in HEM

  6. Comparison of led runs(sect1_RM1)

  7. Comparison of led runs(sect4_RM1) Thesignals which are in the blue circles come from the same cable

  8. Comparison of led runs(sect4_RM1)

  9. Comparison of led runs(sect10_RM2) Thesignals which are in the blue circles come from the same cable

  10. Ledb/Ledh results Sector 15-16-17 has some problem, we still check it

  11. Comparison of pedestal runs(sect1_RM1)

  12. Comparison of pedestal runs(sect1_RM1)

  13. Comparison of pedestal runs(sect16_RM4) Thesignals which are in the blue circles come from the same cable

  14. Comparison of pedestal runs(sect16_RM4)

  15. Comparison of pedestal runs(sect13_RM4)

  16. Comparison of pedestal runs(sect13_RM4)

  17. Pedb/Pedh results

  18. Conclusion • There are some big Rms values on LED results. So the LED must be normalized on PIN diode Response. But I have not done it yet, I am working about it. I need to check it again after normalization. After then we can reach the exact results of this test. • On PED, the sesults are much better then LED as expected. • Histogram comparison could not have been done since some problems on the HistCompareHEM.C script.